3B SCIENTIFIC PHYSICS 1003122 Instruction Sheet

Digital counter with interface

Advertisement

Quick Links

3B SCIENTIFIC
Digital Counter with Interface (115 V, 50/60 Hz) 1003122
Digital Counter with Interface (230 V, 50/60 Hz) 1003123
Instruction sheet
09/12 ALF
1. Safety instructions
The counter conforms to safety regulations for
electrical measuring instruments and control and
laboratory equipment as per DIN EN 61010, part
1. It is intended for operation in a dry environment,
suitable for the operation of electrical equipment
and systems.
Safe operation of the counter is guaranteed,
provided it is used correctly. However, there is
no guarantee of safety if the counter is used in
an improper or careless manner.
If it may be assumed for any reason that non-
hazardous operation will not be possible (e.g. visi-
ble damage), the counter should be switched off
immediately and secured against any unintended
use.
Before using the counter for the first time,
confirm that the specifications printed on the
rear side of the housing are compatible with
the local mains voltage.
Replace a faulty fuse only with one matching
®
PHYSICS
The digital counter with interface is a microproces-
sor based counter. It was specially designed for the
education in Physics.
The instrument has the following functions and
measuring modes:
Frequency counting
Period measurement
Impulse counting
Start A - Stop B
Pass times
Run + Pass times
1
the specifications stated at the rear of the
housing.
Disconnect the counter from the mains be-
fore replacing a fuse.
Never short the fuse or the fuse holder.
2. Description

Advertisement

loading

Summary of Contents for 3B SCIENTIFIC PHYSICS 1003122

  • Page 1 ® 3B SCIENTIFIC PHYSICS Digital Counter with Interface (115 V, 50/60 Hz) 1003122 Digital Counter with Interface (230 V, 50/60 Hz) 1003123 Instruction sheet 09/12 ALF the specifications stated at the rear of the 1. Safety instructions housing. The counter conforms to safety regulations for •...
  • Page 2 The digital counter with interface can be used as a B LED stand-alone instrument or together with a Per- indicator for input B sonal Computer. A Windows programme for IMPULSE Electrical operation and data logging from the instrument impulse input A is supplied with the instrument.
  • Page 3 Hint: Voltage can be measured with a 10 MΩ 4. Technical data multimeter, and multiplied by 2. Input A and B General data Input impedance: 500 kΩ Mains connection: Sensitivity: 200 mV 1003122: 115 V (±10 %), 50/60 Hz Trigger polarity: positive going 1003123:...
  • Page 4 Pendulum When button ‘START/ When button ‘START & single STOP’ is pressed, a /STOP’ is pressed, PASS measu- single measurement is the run time from A to TIME rement started B, and the pass time for A and B are [START] When button ‘START measured.
  • Page 5 every time the push-button ‘START/STOP’ is sed. The counting sequence is continuous, with pressed. 10 seconds’ counting followed by a 5 seconds’ displaylock (for reading the result). The counter LED ‘Input A’ is lit when the input (the gate) is is reset (and restarted) every 10 seconds, even open.
  • Page 6 The number of pass times on each input is con- 5.7 Geiger-Müller amplifi er module stantly shown in the display: ‘2 4’ indicates 2 Geiger-Müller tube is connected to the BNC plug pass times on A and 4 on B. marked ‘GM‘...
  • Page 7 PC. Only active during IMPULSE COUNT and START A - STOP B. Language: Select the language. 3B Scientific GmbH ▪ Rudorffweg 8 ▪ 21031 Hamburg ▪ Germany ▪ www.3bscientific.com Subject to technical amendments © Copyright 2012 3B Scientific GmbH...

This manual is also suitable for:

Physics 1003123