Peradon DCT Conversion Instructions

Conversion instructions from old £1 coin to new £1 coin

Advertisement

Quick Links

Conversion Instructions from
old £1 coin to new £1 coin
DCT / ADM & SCT
128 Richmond Row – Liverpool – L3 3BL
Tel : 0151 298 1470 Fax : 0151 298 2988
email : peradon@eaclare.co.uk
web : www.peradon.co.uk

Advertisement

loading

Summary of Contents for Peradon DCT

  • Page 1 Conversion Instructions from old £1 coin to new £1 coin DCT / ADM & SCT 128 Richmond Row – Liverpool – L3 3BL Tel : 0151 298 1470 Fax : 0151 298 2988 email : peradon@eaclare.co.uk web : www.peradon.co.uk...
  • Page 2 This leaflet describes procedures to convert the Peradon range of meters. The conversion kits should contain the following items: - Pre 2011 DCT 1 x wall bracket fitted with new coin entry plate 1 x runway 1x double sided VHB tape...
  • Page 3 5 Remove two screws from coin bracket and insulation plate (Figure 1) and remaining screw holding runway cover (Figure 2) and lift off. Discard coin bracket and put two screws, insulation plate and runway cover to one side. Remove screws Coin Bracket (& Insulation Plate DCT) Remove screws Figure 1...
  • Page 4 Runway locating holes Optional earth block Terminal Block Relay Figure 3 Figure 4 8 Fit new runway supplied ensuring the lugs are correctly located in the corresponding holes (Figure 3). 9. Re-fit runway cover and insulation plate using retained screws. Attach wall bracket to the wall and re-connect electrical connections ensuring they they are re-connected correctly.
  • Page 5 Post 2011 DCT 1 Switch off electricity supply. 2 Remove cash box. 3 Unlock front cover and lift upwards allowing lower part of cover to come towards you. Pull cover forwards and away from wall bracket and disconnect lead from the power supply board (PSU). See Figure 5.
  • Page 6 ADM & SCT 1 Switch off electricity supply. 2 Remove cash box. 3 Insert a No. 1 nine inch pozidrive screwdriver through the hole uncovered by removing the cashbox and remove the recessed screw holding the front panel (Figure 9). 4 Remove the front panel by pushing downwards as far as possible, pulling the bottom edge slightly outwards and then lifting panel upwards.
  • Page 7 8 Using a nut spinner or spanner of size M3.5 undo the four nuts holding the coin acceptor and remove coin acceptor keeping all fixings. 9 Fit new coin acceptor supplied using retained fixings ensuring earth is correctly fitted. Tighten securely. Refit circuit board(s) and 5-way connector ensuring correct connection (Figures 15 and 16).