Feature
・ Each clamping screw has commercially available O-ring to prevent rotation and keep the direction of arrow marking.
・O-ringshouldbereplacedbythecustomerwhenitisworn.
How To Use
TaperedClampingScrews
Canbeusedforlocatingfixtureplateorworkpiece.
■Mounting-HoleDimension
CP165-LH
Size
CP165-08001
CP165-12001
CP165-16001
*)・ T he hole tolerance should be
Clamping Screws are always mounted on the fixture
plate.Fixtureplateandtaperedbushingfittightlyand
keeptherepeatabilitywithoutchipincursion.
・ T he hole tolerance should be H7 when mounting on
workpiece.Taperedbushingcanbeeasilymounted/
removed.
■Installation
1. F ullytightentheclamping
screwonfixtureplateor
workpiece.
Clamping Screw
CP165-L
Fixture Plate / Workpiece
Lf
Lf
1
M
d
Lf
Lf
1
*)
12
13
5.5
18
19
6.5
22
23
8.0
when Tapered
-0.010
-0.025
2. T urnthescrewcounterclockwise
withinoneturnuntilthearrow
marking points downward.
(Thereisagapbetweenclamping
screwandtaperedbushing.)
Fixture Plate / Workpiece
Clamping Screws
Canbeusedforjustclamping.
■SpacingTolerance
Spacingtoleranceshouldbe±0.02forTapered
Clamping Screws.
**) S pacingtoleranceshouldbe±0.2for
Clamping Screws.
M
M 8 × 1.25
M12 × 1.75
M16 ×
2.00
Note: R efer to the next page for the
Gap
Tapered Bushing (Accurate)
CP157-L
Tapered Clamping
Screw (Hook)
CP165-LH
Tapered Clamping
Screw
CP165-L
Tapered Bushing (Accurate)
CP157-L
Fixture Plate
layoutoftheproducts.
3. I nstall the clamping screws into the
clampingmodules.