Broan PRESTIQUE Series Installation Instructions

Medicine cabinet

Advertisement

Available languages

Available languages

Quick Links

MODEL NO.
SIZE
942224-P1
24"
942230-K1
30"
942236-K1
36"
947224-Q1
24"
947230-Q1
30"
947236-Q1
36"
INSTRUCTIONS FOR
WALL-MOUNT INSTALLATIONS
WARNING: Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
Prepare cabinet.
1. Carefully remove all packing material.
Determine location.
1. The commonly accepted height of bath cabinets is 64" from the finished
floor to the center of the mirror area. However, height may be adjusted
to individual preference.
2. It is recommended that the cabinet be located such that the mounting
screws may be screwed into wall studs to provide maximum strength.
3. Provide 120 VAC power cable through the wall material, directly
behind the light box.
Mount cabinet.
1. Measure and mark four (4) clearance holes in cabinet back at wall stud
locations. Use angle brackets to locate upper holes. (Fig. 1)
2. Drill ¼" dia. clearance holes through cabinet back.
3. Hold angle brackets in place over top set of holes. Mount brackets to
underside of light housing with #6 x ½" screws.
4. Hold cabinet in place and make sure it is level. Screw cabinet to wall
studs.
NOTE: Irregularities in wall surface may cause distortion of cabinet
body when mounted. Place shims between cabinet and wall at appro-
priate corners.
OPTION (If wall studs are not available):
4. Hold cabinet in place and make sure it is level. Mark wall through all four
(4) clearance holes.
5. Set cabinet aside and drill holes in wall material for molly bolts or wall
anchors (not provided).
6. Mount cabinet to wall material.
Connect electrical wiring.
WARNING: Before wiring this product, switch power off at service en-
trance and lock service panel to prevent power from being switched on
accidentally.
1. Remove reflector from wrapper.
2. Remove protective plastic film from reflector and snap light cups onto
sockets.
3. Make electrical connections between house wires and fixture wires on
rear of reflector: black to black, white to white, and greenwire to a per-
manent ground. (FIG. 2)
4. Attach reflector to cabinet.
Mount shelves.
1. Choose the location for the shelves from the five (5) sets of holes lo-
cated on the inside of the cabinet.
2. Insert two (2) shelf tabs into holes, at desired location on one side of the
cabinet. Repeat on the other side, being sure to use holes at the same
height, so the shelf will be level.
3. Set shelves on pins.
Attach mirror doors.
1. Remove wrapping from mirror door. Remove hinge brackets and pres-
sure plates from parts bag.
PRESTIQUE
MEDICINE CABINET
FINISH
White
White
White
For help, call
Oak
Oak
us toll free!
Oak
1-800-637-1453
WIRING
FIG. 1
ACCESS
HOLE
ANGLE
BRACKET
SCREW
#8 x 1½"
SCREW
#6 x ½"
CLEARANCE
HOLES
SHELF
STRIKE
PLATE
MAGNET
URETHANE DISC
FIG. 2
All electrical connections must be made in accordance
with local code ordinances. If you are unfamiliar with
methods of installing electrical wiring, secure the ser-
vices of a qualified electrician.
BLACK TO BLACK
WHITE TO WHITE
HINGE
FIG. 3
BRACKET
BACKSIDE OF
PRESSURE
MIRROR DOOR
PLATE
FIG. 5
2. Peel paper backing from two (2) pressure plates and affix plates to
backside of mirror door at upper-left and lower-left corners. (FIG. 3)
3. Slide hinge bracket(s) over top of door(s) and lightly tighten screws
against pressure plate(s). (FIG. 3)
4. Place a nylon washer on the pin of the remaining hinge bracket and
insert hinge bracket(s) into hole(s) in bottom of frame.
5. Lift mirror door(s) and insert top hinge bracket(s) into hole(s) in top of
frame. (FIG. 4) Slide bottom of mirror door(s) into lower hinge bracket(s)
(FIG. 5) and lightly tighten screws against pressure plate(s). (FIG 6)
6. Remove the 1" diameter strike plate(s) from the parts bag. Peel off the
paper backing and affix plate(s) to rear of mirror door(s) at the lower
corner(s) opposite the magnetic catch(es).
7. Clear urethane discs are furnished to prevent finger marks on mirror
face. To mount: Remove paper backing and affix to mirror face ½" from
bottom and outside edge.
REFLECTOR
SHELF
TABS
LIGHT
SOCKET
SCREW
#6 x 3/8"
CUP
MIRROR
DOOR
HINGE
BRACKET
(Pressure plate
beneath
backside)
NYLON
WASHER
GREEN TO
GROUND
WIRE
FIG. 4
FIG. 6
A99042675C

Advertisement

loading

Summary of Contents for Broan PRESTIQUE Series

  • Page 1 PRESTIQUE WIRING REFLECTOR FIG. 1 SHELF ACCESS MEDICINE CABINET TABS HOLE ANGLE BRACKET MODEL NO. SIZE FINISH LIGHT 942224-P1 24” White SOCKET SCREW 942230-K1 30” White #8 x 1½” SCREW 942236-K1 36” White For help, call 947224-Q1 24” #6 x 3/8” SCREW 947230-Q1 30”...
  • Page 2 TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 3 PRESTIQUE FIG. 1 SOPORTES REFLECTOR PARA REPISA ORIFICIO DE ACCESO CABINA DE LA MEDICINA PARA LA CONEXIÓN SOPORTE MODELO No. TAMAÑO ACABADO ANGULAR 942224-P1 609 mm (24") Blanco RECEPTÁCULO 942230-K1 762 mm (30") Blanco Para la ayuda, DEL FOCO 942236-K1 914 mm (36") Blanco TORNILLO...
  • Page 4 Para que pueda recibir el servicio de la garantía, debe (a) notificar a Broan en el domicilio que se especifica a continuación o al teléfono 1-800-637- 1453, (b) dar el número de modelo y la identificación de la pieza y (c) describir la naturaleza de cualquier defecto del producto o parte del mismo. El en momento de solicitar servicio por la garantía, debe presentar un comprobante de la fecha original de la compra.

This manual is also suitable for:

Prestique 942224-p1Prestique 942230-k1Prestique 942236-k1Prestique 947224-q1Prestique 947230-q1Prestique 947236-q1