Download Print this page

HySecurity MX2890-01 Installation Instructions

Advertisement

Quick Links

Battery Charger Replacement
Review the illustrations and follow the steps to replace the battery charger.
• MX2890-01 DC Charger 230V replacement
• MX2890-02 DC Charger 115V replacement
Tools required
Box end wrenches: 7/16 and 9/16 inch
Crescent wrench
Phillips head screwdriver
Socket wrenches: 7/16 and 9/16 inch
1/4 - inch Hex key
WARNING
Prevent Electrical Shock! Do NOT touch both poles of the battery at the same time!
Serious injury and shock will occur. Be sure the black wire on the negative terminal of the
battery is disconnected. Read and follow step 2.
1. Use two 7/16-inch box end wrenches and remove the two hex head
bolts that secure the lip to the battery shelf. Loosen the third bolt, but
do not remove it.
2. Pull the battery out to access the negative terminal. Disconnect the
wire from the battery using a crescent and 9/16-inch wrench.
3. Using a 9/16-inch wrench, remove the white/tan battery charger wire
from the backside/base of the ON/OFF disconnect switch. Return the
red battery wire to the terminal and tighten the nut securely.
4. Remove the black battery charger wire from the upper lug on the
circuit breaker.
www.SecureOpeners.com | (800) 878-7829 | Sales@SecureOpeners.com
Installation Instructions
DANGER
Turn OFF AC Power at the source (circuit breaker panel) before accessing the wires in the UPS
cabinet. Follow facility Lock Out/Tag Out procedures. Make sure all power switches are in the OFF
position. Follow all electrical code standards and regulations.
24V Fuse (5A)
12
4
Remove black
(-) LUG
charger wire.
12
3
(-)
(+) LUG
Disconnect
white/tan wire.
12
2
Disconnect
battery wire.
12
1
MX2890-01, MX2890-02
Wires to the
Smart Touch Controller
AC Power
Line Voltage Fuse
(15A)
+ -
JUMPER CABLE
Remove two of the fasteners
that secure the shelf.
Loosen, do
NOT remove.

Advertisement

loading

Summary of Contents for HySecurity MX2890-01

  • Page 1 Installation Instructions MX2890-01, MX2890-02 Battery Charger Replacement DANGER Turn OFF AC Power at the source (circuit breaker panel) before accessing the wires in the UPS Review the illustrations and follow the steps to replace the battery charger. cabinet. Follow facility Lock Out/Tag Out procedures. Make sure all power switches are in the OFF • MX2890-01 DC Charger 230V replacement...
  • Page 2 Disconnect All DC Charger Wiring AC Power (-) LUG (+) LUG www.SecureOpeners.com | (800) 878-7829 | Sales@SecureOpeners.com...
  • Page 3 Replace Battery Charger with HyCharger Place foam insulation around fan portal to protect it and provide weather stripping. Remove charger. Remove 4 fasteners. Align the HyCharger with the rear mounting holes and secure it to the shelf with the two fasteners provided.
  • Page 4 Finalize the installation by taking the following steps: • Double check the wiring connections. Make sure they are correctly For technical support, call your installer or authorized HySecurity attached and secured. See illustrations. distributor. Obtain the serial number of your operator before calling. It’s located near the power label on the operator.