Banner SureCross DX99 FlexPower Series Manual

Polycarbonate housing

Advertisement

Quick Links

SureCross DX99 FlexPower Node (Polycarbonate Housing)
Switch configurable Node with two discrete inputs and two analog inputs (powered by external battery module only)
For additional information, updated
documentation, and accessories, re-
fer to Banner Engineering's website,
www.bannerengineering.com/sure-
cross.
Model (0 to 20 mA)
DX99N9X2S2N0M2X0A2
DX99N2X2S2N0M2X0A2
DX99N9X2S2N0M2X0A1
DX99N2X2S2N0M2X0A1
Model (0 to 10V)
DX99N9X2S2N0V2X0A2
DX99N2X2S2N0V2X0A2
DX99N9X2S2N0V2X0A1
DX99N2X2S2N0V2X0A1
Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
P/N 142496 Rev. F
The SureCross® wireless system is a radio frequency network with integrated I/O that can oper-
ate in most environments and eliminate the need for wiring runs. DX99 wireless networks are
formed around a Gateway, which acts as the wireless network master device, and one or more
Intrinsically Safe Nodes.
• Wireless industrial I/O device with two selectable discrete inputs and two analog inputs
• FlexPower® power input requires power from the DX81H Battery Supply Module
• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Access
(TDMA) control architecture ensure reliable data delivery within the unlicensed Industrial, Sci-
entific, and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node, including
fully acknowledged data transmission
• Lost RF links are detected and relevant outputs set to user-defined conditions
• DX99 Polycarbonate housings are certified for use in Class I, Division 1, Groups A, B, C, D;
and Zone 0 (Category 1G) when properly installed in accordance with the National Electrical
Code, the Canadian Electrical Code, or applicable local codes/regulations
Frequency
Boost Voltage
900 MHz ISM Band
18V
2.4 GHz ISM Band
900 MHz ISM Band
10V
2.4 GHz ISM Band
Frequency
Boost Voltage
900 MHz ISM Band
18V
2.4 GHz ISM Band
900 MHz ISM Band
10V
2.4 GHz ISM Band
Inputs and Outputs
Discrete Mode
Inputs: Two selectable discrete
Switch Power: Two, Configurable
Inputs and Outputs
Discrete Mode
Inputs: Two selectable discrete
Switch Power: Two, Configurable
7/1/2013
Analog Mode
Inputs: Two selectable discrete, two
0 to 20 mA analog
Switch Power: One, Configurable
Analog Mode
Inputs: Two selectable discrete, two
0 to 10V analog
Switch Power: One, Configurable
0 142496
6

Advertisement

Table of Contents
loading

Summary of Contents for Banner SureCross DX99 FlexPower Series

  • Page 1 DX99N2X2S2N0V2X0A1 2.4 GHz ISM Band Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death.
  • Page 2: Setting Up Your Wireless Network

    The UCT requires a special USB to RS-485 (model number BWA-UCT-900 for 1 Watt radios, BWA-HW-006 can be used for all other radios) converter cable to pass infor- mation between your computer and the Gateway. Download the most recent revi- sions of the UCT software from Banner Engineering's website: http://www.banneren- gineering.com/wireless.
  • Page 3 SureCross DX99 FlexPower Node (Polycarbonate Housing) DIP Switch Settings Switches Device Settings Rotary dial address mode OFF* Extended address mode Analog Configuration OFF* Discrete Configuration * Default configuration Address Mode The SureCross wireless devices may use one of two types of addressing modes: rotary dial addressing or extended addressing. In rotary dial address mode, the left rotary dial establishes the network ID and the right rotary dial sets the device ID.
  • Page 4 SureCross DX99 FlexPower Node (Polycarbonate Housing) * Default positions Analog Configuration - Switch 2 OFF (18V Boost Models) For analog configuration, DIP switch 2 is in the OFF position (factory default). Analog configuration has analog IN 1 linked to switch power 1 (SP1) and is programmable using switches four through eight.
  • Page 5 SureCross DX99 FlexPower Node (Polycarbonate Housing) Discrete Configuration, Switch 2 ON DIP Switches Descriptions Sample/Report Rate 1 second Sample/Report Rate 2 seconds Sample/Report Rate 16 seconds Modbus or UCT configured (overrides DIP switches) Discrete IN 1 uses switched power 1 (SP1). Discrete IN 2 uses switched power 2 (SP2). Analog inputs 1 and 2 are disabled. * Default positions Discrete Input Type Select the type of discrete input sensors to use with this device: sourcing (PNP) sensors or sinking (NPN) sensors.
  • Page 6: Modbus Register Table

    SureCross DX99 FlexPower Node (Polycarbonate Housing) LED 1 LED 2 Node Status Radio Link Ok (flashing green) Device Error (flashing red) (flashing red) No Radio Link (flashing red, 1 per 3 sec) Modbus Register Table Modbus Holding Register I/O Type I/O Range Holding Register Represen- Terminal Block...
  • Page 7 SureCross DX99 FlexPower Node (Polycarbonate Housing) Radio General 2.4 GHz Compliance Interface FCC ID UE300DX80-2400 - This device complies with FCC Indicators: Two bi-color LEDs Part 15, Subpart C, 15.247 Buttons: Two ETSI/EN: In accordance with EN 300 328: V1.7.1 (2006-05) Display: Six character LCD IC: 7044A-DX8024 Wiring Access...
  • Page 8: Banner Engineering Corp Limited Warranty

    ER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.

This manual is also suitable for:

Surecross flexpower dx99n9x2s2n0m2x0a2Surecross flexpower dx99n2x2s2n0m2x0a2Surecross flexpower dx99n2x2s2n0m2x0a1Surecross flexpower dx99n9x2s2n0m2x0a1Surecross flexpower dx99n9x2s2n0v2x0a2Surecross flexpower dx99n9x2s2n0v2x0a1 ... Show all

Table of Contents