Download Print this page

Gantner GAT NET.Controller 7000 Series Manual

Control unit for the gat net.lock 7000

Advertisement

Quick Links

GAT N ET.Controller 7000
Control unit for the GAT N ET.Lock 7000
Application
The GAT NET.Controller M 7000 (master controller) and S 7000 (slave
controller) control units are used to connect and control the GAT NET.
Lock 7000 electronic locker locks from GANTNER.
The control units operate in online mode and communicate with a host
PC/server. The GAT NET.Controller M 7000 master controller serves as
the communication bridge between the host PC/server and the GAT NET.
Controller S 7000 slave controllers.
For system flexibility, different slave controllers are available to suit the
leading RFID technologies (see order information).
Functional description
The correct type of slave controller must be used to suit the RFID technology
in operation. The slave controllers are connected to the master controllers
via a serial RS 485 interface. Each master controller can control up to 8
slave controllers and 192 locks over a maximum cable length of 200 m.
For smaller MIFARE
®
/ISO systems, a light version of the slave and master
controllers is available (see functionality table).
In online operation, the slave controllers receive data carrier information
via the connected locks. This information is sent via the master controller
to the PC/server for authorization. The current status of the locker system
is also forwarded to the PC/server, thereby allowing the status of each
locker to be visualized using, for example, GANTNER PC software. An
emergency mode function for online mode ensures operation continues if
communication to the PC/server is temporarily interrupted.
Highlights
• Connection of locks via industry-standard MOLEX plugs
• LED status display
• Simple configuration with GANTNER software tools
• Firmware update via host interface possible
• Diagnostic system for detecting lock problems
• Integration into alarm system (locker break-in alarm)
Accessories
Description
GAT NET.Lock 7000
Electronic locker lock
GAT NET.Lock Cable 5m
5 m connection cable for the GAT NET.Lock 7000, 4-pin
MOLEX plug on both ends
GAT NET.Lock Cable Extension 3m
3 m extension cable for the GAT NET.Lock 7000
GAT NET.Power Supply 230V
Power supply unit
GAT NET.Power Cord xxx
Power cord for power supply unit. 494181 (EU), 494282
(UK), 511474 (AUS), 636835 (US), 636734 (IND)
GAT NET.Power Plug
Plug to forward the power supply
GAT Patch Kabel 5805
5 m, shielded Ethernet patch cable with 8-pin RJ45 plugs
www.gantner.com
Order information
Description
GAT NET.Controller M 7000
Master controller for max. 8 GAT NET.Controller S 7000 slave
controllers
GAT NET.Controller M 7000 Light
Master controller for max. 3 GAT NET.Controller S 7000 slave
controllers, no relays and no optocouplers
GAT NET.Controller M 7000 Light ext.
GAT NET.Controller M 7000 Light extension license for max.
8 GAT NET.Controller S 7000 slave controllers
GAT NET.Controller S 7000 F/ISO
MIFARE
/ISO 15693 slave control unit for max. 24 GAT
®
NET.Lock 7000 electronic locks
GAT NET.Controller S 7000 F/ISO Light
MIFARE
®
/ISO 15693 slave control unit for max. 12 GAT
Part No.
NET.Lock 7000 electronic locks
368534
GAT NET.Controller S 7000 B
LEGIC
slave controller for max. 24 GAT NET.Lock 7000
®
734430
GAT NET.Controller S 7000 ICLS
iCLASS
slave control unit for max. 24 GAT NET.Lock 7000
®
Controller functionality table (F/ISO)
810021
369434
Number of
relays
See
Number of
description
optocouplers
Max. no. of
slave units
370426
Max. no. of
NET.Locks
909321
*expandable to 8 with additional license (Part No. 978440)
Valid from September 15
th
DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835
GAT NET.Controller M 7000
GAT NET.Controller S 7000
Master
Master
Standard
Light
4
0
4
0
8
3*
192
36
(via slaves)
(via slaves)
2015 • Technical data subject to modification without notice!
Part No.
253224
978541
978440
253426
429730
253325
768538
Slave
Slave
Standard
Light
-
-
-
-
-
-
24
12
1

Advertisement

loading

Summary of Contents for Gantner GAT NET.Controller 7000 Series

  • Page 1 PC/server, thereby allowing the status of each Master controller for max. 8 GAT NET.Controller S 7000 slave locker to be visualized using, for example, GANTNER PC software. An controllers emergency mode function for online mode ensures operation continues if GAT NET.Controller M 7000 Light...
  • Page 2: Technical Data

    GAT NET.Controller S 7000 GAT NET.Controller S 7000 GAT NET.Controller S 7000 Plug GAT NET.Lock 7000 Identification with RFID data carrier Lockers Valid from September 15 2015 • Technical data subject to modification without notice! www.gantner.com DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835...
  • Page 3: Installation

    4. Screw the third screw into the bottom mounting hole and tighten firmly. 5. Ensure the controller is secured firmly and cannot be removed. Valid from September 15 2015 • Technical data subject to modification without notice! www.gantner.com DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835...
  • Page 4 1. Reset of controller (see manual) 2. Delete configuration = reset to default (see manual) - MODE: Perform automatic antenna adjustment (see manual) Valid from September 15 2015 • Technical data subject to modification without notice! www.gantner.com DB_GAT-NETCONTROLLER7000--EN_23.indd • Part No.: 573835...
  • Page 5 Ethernet: min. CAT 5 (STP) RS 485: min. CAT 5 (STP), 200 m max. cable length per RS 485 line. The WEEE symbol on GANTNER products and their packaging indicates that the corresponding material must not be disposed LED signaling of with normal household waste.

This manual is also suitable for:

Gat net.controller m 7000Gat net.controller m 7000 light ext.Gat net.controller m 7000 lightGat net.controller s 7000 f/isoGat net.controller s 7000 f/iso lightGat net.controller s 7000 b ... Show all