Caution
As this is a keyless digital door lock, damage may occur
to parts of the dead lock system if it is not used according
to the manual. Users should be fully aware of the manual
and how to operate this product.
Registering and changing the password
The door must be opened while registering the password.
Caution
1. Open the battery cover of the back ass'y, and
2. Check that the front keypad lamp is
short press the [Reg.] button one time.
turned on.
3. Enter the password of 3-20 digits.
4. Press the [Reg.] button. Then, the
4.
registration will be completed while a
sound is generated for checking the
registration.
If no password is entered within 14 seconds after the [Reg.] button is pressed, the
registration process will be cancelled. When a new password is registered (The above 1-4
steps), the previous one will be automatically deleted. If the registration mode is cancelled,
Caution
the previous password will be maintained.
Registering (again) the digital touch key / smart tag (card)
When it is needed to register digital touch keys, smart tags (cards) and remote control,
or registering them again, it is required to register them all together at once.
Remote control is optinal. purchasing it separetly.
Caution
1. Open the battery cover of the back ass'y, and short
2. Bring the digital touch keys into contact at the touch plate
press the [Reg.] button one time.
in order. (When each digital touch key is comes in contact at the
touch plate, the registration will be completed while a sound is
generated for checking the registration)
※ Bring the smart tag (card) into contact at the touch plate.
3. Press the [Reg.] button after registering all
4. Registering the remote control (option): Short press the
digital touch keys or smart tags (cards).
[Reg.] button of the back ass'y one time, and the press the
[Open] button for registration.
Safety precautions
The precautionary measures are for the safety of the user, for the prevention of property
damage, and for the avoidance of any inconveniences due to an accident. These must be read
and followed properly.
Warning
• Do not disassemble or alter the lock.
• Place the batteries carefully and correctly according
• Do not install where the distance over
to their polarity (+/-). If the batteries are inserted
5mm between the door and door frame.
in a wrong way, differently from the indicated
• Please do not expose the password and
direction or polarity, leakage or rupture could occur.
change the password in regularly.
Pay attention to it.
• Batteries should not be exposed directly to
• Please do not mix old with new batteries or use
heat sources or flames, or submerged in water,
different types.
because they may leak or explode, resulting in
Always use new alkaline batteries.
severe damage. Please do not use damaged
• Do not clean the product with flammable materials
batteries.
such as alcohol, benzene or thinners. Such materials
• Do not press using sharp tools or press
may damage the surface or cause a fire.
numeric button excessively.
• Replace the current batteries with new ones within
• Make sure the door is completely locked when
1 week after the battery replacement notification
going out.
melody sounded off for the first time.
Components
Rubber pad for
Front ass'y
Back ass'y
the back ass'y
screws
Battery 4pcs
Installation template
Components of each model
Model
Door opening type
6400D
2way / Password & Digital key
(2W)
6400S
(2W)
2way / Password & Smart key
6400SK
3way / Password & Digital key& Mechanical key cylinder
(3W)
6400DK
(3W)
3way / Password & Smart key& Mechanical key cylinder
The lifetime of the batteries is based on the result of the tests by the company and is not an absolute
measurement. It will vary depending on the temperature and humidity of the installed locations as well as
depending on the frequency of usage and the quality of batteries.
The functions, design, and composition of the product may change without prior notification for the purpose of
Caution
improving its quality.
When it is needed to register additional digital touch keys and smart tags (cards)
(totally 50pcs of keys can be registered), it is required to repeat the above process
2 before the keypad lamp is turned off.
Attention
If neither the digital touch key nor the smart tag (card) is contacted or if the [Open] button is
not pressed, in case of the remote control, for 14 seconds after the [Reg.] button is
pressed, the registration process will be cancelled. When a new digital touch key, smart tag
(card) or a new remote control is registered (The above 1–4 steps), the previous one will be
Caution
automatically deleted.
Deleting the digital touch key, smart tag (card),
and remote control
1. Open the battery cover of the back ass'y, and
short press the [Reg.] button one time.
2. Check that the front keypad lamp is turned on.
3. Press number [0] for 5 seconds. All the digital
touch keys, card keys and remote control
will be deleted while a sound will be gener
-
ated for checking.
For 5
seconds
Locking the door from the inside
When the auto lock function is set.
After 3 seconds
When the auto lock function is set, the door will be automatically locked 3 seconds
after the door is closed.
When the Manual lock function is set.
Press [Double locking] one time
Short press [Double locking] button one time.
then door will be closed.
Front ass'y
Smart key
Mortise
Strike
Handle shaft
Panic release function with handle
Handle shaft stop ring
The handle is a one-touch type product developed by the company. When it is installed successfully,
the user just needs to swing it down to open the door safely and conveniently when moving
from the inside area to the outside area.
User manual
User manual
Mechanical key
Option
Video phone
interface,
remote control
Mortise
Dead bolt
(locking section)
Latch bolt
This is fixed, the right-hand door mode is set to default, meaning that any additioanl
adjustment isn't needed for the right-hand users. If the door is a left-hand type, the latch bolt
should be adjusted. otherwise, the door will not be closed.
Opening the door from the inside.
If the user does not open the door within 7 seconds after pulling the
handle down, the door will be automatically locked.
Caution
▶ Pulling the back handle down
Pull the handle of the back ass'y down slightly. Then, the
disabling the locked state and opening the door.
Opening the door from the outside.
Opening the door by using the password.
Push the keypad up.
Enter the password.
When there is a sound for checking, the user just
needs to bring the handle down to open the door.
▶Opening the door by using the digital touch key, smart
tag (card) or the remote control.
1. Bring the registered digital touch key or smart tag key into contact at the touch plate, or press the
[Open] button in case of the remote control.
2. When there is a sound for checking. Then, the user needs to bring the handle down to open the door.
▶Opening the door by using
the mechanical key cylinder.
Insert the key into the key hole and turn
it to open the door.
Back ass'y
Keypad cover
Battery cover
Emergency power
supply terminal
Keypad
Wireless
6400D (2W)
communication
6400DK (3W)
receiver
Registration
button
Emergency key insertion
6400SK (3W)
Double locking
6400DK (3W)
Front handle
Back handle
Touch plate
6400S (2W) and 6400SK (3W)
※ In addition to 2 or 4 pcs of smart tag that are
provided basically, 13.56Mhz ISO 14443A
type RF tags, NFC cards and credit cards can
be also registered as card key
Panic release function
will be activated,

Advertisement

loading

Summary of Contents for Unicor 6400 Series

  • Page 1 (2W) 2way / Password & Smart key interface, 6400SK 3way / Password & Digital key& Mechanical key cylinder (3W) remote control UNICOR HIGHTECH CO., LTD Mortise 6400DK (3W) 3way / Password & Smart key& Mechanical key cylinder www.unicor.co.kr Dead bolt - This manual may change without notice in case of product improvement.
  • Page 2 If the warning sound continues or the deadbolt does not work normally, it is required The emergency power can be supplied when keeping the 9V battery into contact at the input terminal UNICOR HIGHTECH CO., LTD to adjust the position of the door lock, requiring the user to contact a shop that can...

This manual is also suitable for:

6400d6400s6400dk6400sk