Download Print this page
olympia electronics MLD-28D/w/MAR Manual

olympia electronics MLD-28D/w/MAR Manual

Advertisement

Quick Links

MAINTAINED EMERGENCY ILLUMINATION SIGNS (for ships)
TECHNICAL CHARACTERISTICS
Mains voltage
Maximum power consumption
Battery (Ni-Cd)
Battery protection
Recharging time
Minimum emergency duration
Light source intensity (Mains / Emerg)
Degrees of cover protection
Class of cover protection
Produced in accordance with
Operation temperature range
Relative humidity
External panel's dimensions
External dimensions (LxWxH)
Typical weight
Guarantee
Thank you for purchasing this product of Olympia
Electronics. A European manufacturer.
GENERAL
These sign illumination luminaires use a new
technology, friendly to the environment , with high
illuminated L.E.D.s. L.E.D. technology has very
low power consumption.
These luminaires are used on ships (indoors) (ta
o
40 C) where emergency light is needed.
In this type of marking panels, the PVC overlay is
mounted on the marking panel with 4 plastic screws,
and it can be changed by change the PVC overlay in
accordance with the desired result.
Each model combines modern, aesthetics, together
with
functionality. The exit illumination
used in every public area where clear direction and
good appearance are important.
All models must be permanently connected to the
mains power supply as shown on page 2.
The legend is screened on to a clear acrylic sheet
which has the marking on the marking panel with the
light that comes from the top of the luminaire and
diffracts, giving light to the marking panel.
The luminaire has an indication (CHARGE) for the
charging of the battery and a (TEST) button to TEST
the emergency circuit and the LEDs for
operation only when the luminaire is powered by the
mains power supply. The unit must be mounted in a
clearly visible area and can either be hung on a
ceiling or mounted on a wall depending on the
requirements of the installation. The
includes all the required materials for mounting on
the wall or on the ceiling. The pages 2 and 3 show
us the mounting methods.
WARNING !!
1. Read carefully this instruction manual.
2. Before service interrupt the mains power supply.
3. The device must be connected to the mains power
supply thru a fuse dependent by the total amount of
Page 1 from 5
High Quality European based Manufacturers
MLD-28D/w/MAR
3W / 7.5VA
Overcharging and full discharging protection
85lm/85lm
class II + IEC 60092-306
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3, EN 1838 + IEC 60092-306
280x100mm
305x25x155mm
520gr.
3 years (1 year for the battery)
the line's power load.
4. It is sugested to check every month the indication
LED for battery charging, and by pushing briefly the
TEST button to check the emergency cirquit. The sign
should light for a few seconds powered by the battery
and then, will turn to normal
condition contact the installer.
5.
Every six months, a
carried out
Count the autonomous duration of the luminaire and
in case of no correspondence to stated emergency
duration replace the battery The replacement of the
battery must be done using parts of the same type, by
the manufacturer or by a competent person.
signs are
6. In case of inactive use for a period greater than 2
months, disconnect the battery by pulling out the
battery's connector.
7 Replaced batteries must not be thrown into
.
trash bins. They must be returned to special
battery disposal points. Do not incinerate.
NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
1: Maintained (*)
good
A: Including test device
180: 3 hour duration
(*) Maintained operation: The luminaire lights its
illumination source, when it is powered by the mains
power supply or not.
package
Non-Maintained operation: The luminaire lights its
illumination source, only in power supply's failure.
MLD-34D/w/MAR
220-240V AC/50-60Hz
3.6V/1Ah
24h
3h
105lm/85lm
IP 40
ο
0-40 C
up to 95%
340x170mm
365x25x225mm
operation. In the opposite
full
duration check should be
by disconnecting the mains power supply
.
3W / 8VA
850gr.
.
922503465_09_001

Advertisement

loading

Summary of Contents for olympia electronics MLD-28D/w/MAR

  • Page 1 High Quality European based Manufacturers MAINTAINED EMERGENCY ILLUMINATION SIGNS (for ships) MLD-28D/w/MAR MLD-34D/w/MAR TECHNICAL CHARACTERISTICS Mains voltage 220-240V AC/50-60Hz Maximum power consumption 3W / 7.5VA 3W / 8VA Battery (Ni-Cd) 3.6V/1Ah Battery protection Overcharging and full discharging protection Recharging time...
  • Page 2: Mounting Methods

    Mounting methods Preparation procedure Connection of the included terminal block for ceiling mounting BROWN 230V AC BLUE Attention!!! Interrupt the mains power supply. Hanging installation on suspended ceilings using the special mounting brackets 1. Open the pre-etched knock out and pass the cable thru.
  • Page 3: Wall Mounting

    1,5mm². Install the electrical box in an appropriate area in the ceiling. Install securely the 3 pole terminal block and perform the connection according to figure 3. The electrical box and the 3 pole terminal block are not provided by olympia electronics. Page 3 from 5 922503465_09_001...
  • Page 4 Battery replacement process Before service interrupt the mains power supply. 1 Remove the plastic cover from each side. (figure 1, step 2). 2 Unfasten the mounting screws to unmount the illumination sign (figure 1, step 4). 3 You have to disconnect the power supply wires of the sign from the terminal block. 4 Unfasten the mounting screw of the bracket and remove it.
  • Page 5: Troubleshooting

    Troubleshooting Trouble Solution The battery has lost it’s energy Wait at least for 1 hour for the battery to be charged. The battery is not connected 1. The illumination sign does not light when the TEST Attach the battery’s connector to the appropriate button is pressed.

This manual is also suitable for:

Mld-34d/w/mar