Download Print this page

ray allen G405 Installation Instructions

Stick grips

Advertisement

Quick Links

The Ray Allen Company
1341 Distribution Way Suite 15, Vista, CA 92081 USA Phone 760 599 4720 FAX 760 599 4383
Your G4 series stick grip comes pre-wired with color coded, Teflon insulated, 24 gauge wire leads. Relays must be used to
actuate Ray Allen servos. See other side for REL-2 wiring instructions.
Secure the G4 switch module with set screws or pop rivets (not included). Caution! Make sure that these screws do not
interfere with any wires. If the foam grip fits too tight, try blowing compressed air to expand the foam as you slide the foam
grip down the stick tube. The following describes the different color wire functions:
White – PTT. This wire will connect to ground when the PTT button is depressed.
Black – Ground wire. Connect to ground. Shared with all G4 switches.
Red – "Down" (#1) trim switch. This wire will connect to ground when this button is depressed.
Blue – "Left" (#4) trim switch. This wire will connect to ground when this button is depressed.
Green – "Up" (#3) trim switch. This wire will connect to ground when this button is depressed.
Orange – "Right" (#2) trim switch. This wire will connect to ground when this button is depressed.
Grey* – Auxiliary "Right" pushbutton. This wire will connect to ground when this button/toggle is activated.
Yellow* – Auxiliary "Left" pushbutton. This wire will connect to ground when this button/toggle is activated.
Blue/White
* There is a
attached to the upper terminal of the
optional type 3, 4 or 5 toggle switches.
Blue (#4)
Green (#3)
Black - Connect to ground
G405-G407 version 0416
www.rayallencompany.com
G405 and G407 Stick Grips
Installation Instructions
Yellow
, 26 gauge wire
Warning: Installation and use of Ray Allen Company products is the responsibility of the aircraft designer and builder.
Use of Ray Allen products in any application which will exceed their capability can cause failure leading to injury or death.
Inc.
Red (#1)
Grey
Orange/White
* There is a
wire attached to the upper terminal of the
optional type 3, 4 or 5 toggle switches.
Orange (#2)
White (PTT)
, 26 gauge

Advertisement

loading

Summary of Contents for ray allen G405

  • Page 1 Warning: Installation and use of Ray Allen Company products is the responsibility of the aircraft designer and builder. Use of Ray Allen products in any application which will exceed their capability can cause failure leading to injury or death. G405-G407 version 0416...
  • Page 2 REL-2 Servo Relay Deck Installation Instructions Secure the REL-2 Servo Relay Deck to the airframe or simply tie it onto a bundle of wires. Wire according to diagram below. Do not install the REL-2 where it is exposed to excessive heat or vibration. The REL-2 is rated at 1 amp. Fuses and circuit breakers are not included.

This manual is also suitable for:

G407