INSTALLATION INSTRUCTIONS
Modulinear (ML2 LED Fixture – New Construction)

Important Safety Instructions:

-
Read all instructions before installing this luminaire.
-
To prevent risk of electrical shock, turn off electricity at the fuse box before proceeding.
-
This product must be installed in accordance with the applicable NEC and Local codes by a person
familiar with the construction and operation of the product and the hazards involved.
-
Do not install insulation within 3 inches (76mm) of any part of this luminaire.
-
Blinking light of this thermally protected luminaire may indicate overheating.
-
Maximum of (6) 12AWG thru branch conductors suitable for 90°C permitted in wiring box.
-
Suitable for damp locations.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
Fixture Installation:
1. Locate tools included:
a. 3mm Hex Key
b. 6mm/7mm Hex Wrench
2. Cut appropriately sized opening in ceiling
3. Attach the two "L" Brackets to the bottom of the fixture (facing the room), using the two screws
located at either end. Larger "L" Bracket should be installed on the end with the wiring box, and
smaller "L" Bracket should be installed on the other end as shown. (Use the Hex Wrench to tighten
the Hex nuts if necessary)
4. Mount Butterfly Brackets to the vertical slots on the "L" Brackets. The mounting studs should pass
through the slots and assembled with the Wing Nuts and Washers provided. (For Flat hanger bar,
use the vertical slots along the two edges of the Butterfly Brackets. For ½" Conduit or "C" Channel
Bar, use the larger openings).
5. Use the 3mm Hex Key to adjust the mounting height of the LED compartment if necessary. Fixture
height can be adjusted by loosening the four socket head screws inside the fixture. Proper
mounting height is achieved when the edges of the LED compartment are flush with the bottom of
the ceiling.
6. Important: Attach the Safety Cables securely to the building, then connect the fixture wires to the
building wires. Ensure that the Thermal Protector is properly wired, since an improper connection
could result in the fixture overheating.
Model
Cutout (L x W)
ML2-1LT
6 ¼" x 4 ½"
ML2-2LT
10 ¼" x 4 ½"
ML2-3LT
14 ¼" x 4 ½"
ML2-4LT
18 ¼" x 4 ¼"
15 Harbor Park Drive • Port Washington • NY 11050
219 South 6th Avenue • City of Industry • CA 91746
Tel: 800.527.7796 Fax: 855.265.5768
Tel: 626.333.3661 Fax: 626.333.2955
jescolighting.com

Advertisement

loading

Summary of Contents for Jesco Modulinear ML2 Series

  • Page 1: Important Safety Instructions

    INSTALLATION INSTRUCTIONS Modulinear (ML2 LED Fixture – New Construction) Important Safety Instructions: Read all instructions before installing this luminaire. To prevent risk of electrical shock, turn off electricity at the fuse box before proceeding. This product must be installed in accordance with the applicable NEC and Local codes by a person familiar with the construction and operation of the product and the hazards involved.
  • Page 2 LED Module Installation: 1. Housing interior has two flanges on each end to install LED Module. Flanges on one end have tapped holes with two screws attached, and flanges on the other end have no holes. Remove the two screws and keep for later. 2.

This manual is also suitable for:

Modulinear ml2-1ltModulinear ml2-2ltModulinear ml2-3ltModulinear ml2-4lt