Download Print this page

Lindsay LHA Series Instruction Manual

Catv distribution amplifier

Advertisement

Quick Links

LHA Series CATV Distribution Amplifiers
Model
LHA41RM-1GHz (42/54)
LHA41RM-1GHz (65/85)
LHA series CATV Distribution Amplifiers with active return are broadband indoor GaAs-PushPull, high output level
distribution amplifiers designed for RF distribution systems such as those in Cable Television Apartments, Hotels,
Hospitals and other applications where a high quality low noise figure amplifier is necessary to amplify the signals in
both the forward and return paths.
The LHA41RM fills out the selection of 1GHz Distribution Amplifiers giving you extra reach and higher output.
Designed with flat operational gain of 41 dB in the forward band and 18 dB in the reverse band. The LHA41RM has
sockets for JXP style plug-in controls, including input pad and equalizer and interstage equalizer for forward bandwidth
for balancing, and input pad plus output pad and equalizer for reverse path balancing.
The amplifiers are self powered and compatible with 117 and 230V systems
FEATURES
GaAs-Fet Push Pull
for
high
output
levels
with
low
distortions
Active reverse,
JXP style plug-in
controls,
RFI housing,
Surge protection on
all ports,
Diecast
aluminum
housing
for
heat
dissipation,
117/
230
Volt
powering.
Bandwidth
5-42 MHz / 54-1000 MHz
5-65 MHz / 85-1000 MHz
SPECIFICATIONS(Typical)
Typical, for T = 20degC, Zin = Zout = 75 ohms
Parameter
Notes
Bandwidth
Technology
Min Full Gain
Flatness
Return Loss, IN/OUT
Test Points, IN/OUT
directional coupler
Gain Control
JXP plug-in
Slope Control
JXP plug-in
Forward Distortions:
40/50dBmV (54/1000MHz) output level, 79 NTSC channels, digital at -6dB after 550MHz
CTB
on ch78
CSO
on ch78
Xmod
on ch2
Forward Distortions:
36/46dBmV (54/1000MHz) output level, 79 NTSC channels, digital at -6dB after 550MHz
CTB
on ch78
CSO
on ch78
Xmod
on ch2
Reverse Distortions:
52dBmV flat output, 4 ch
3rd on T10
2nd on T9
Xmod on T10
Noise Figure
with 0dB jumpers
Group Delay
ch2
41-42MHz
5-6MHz
Hum Modulation
RFI Isolation
Surge Withstand
IN / OUT
Powering
Power Consumption
Temperature
Enclosure
Weight
Dimensions
* Noise Figure at 5MHz is max.8dB
Instruction Manual
LHA Series 1 GHz
Powering
90-240VAC
90-240VAC
Forward
Reverse
54/85-1000
5-42/65
GaAs
GaAs
41
18
+/-1
+/-1
-16
-16
-20
-20
in
in / out
in / mid
out
-70
-72
-73
-83
-74
-80
-68
-65
-64
6
7 (*)
<40
<35
<40
-80
-100
IEEEC62.41 Cat.A3(6kV,200A)
Mains, 90-240
15
-10 to +55
IP54 Category, Diecast Aluminium
2.8 (6.2)
21 x 17 x 9 (7-5/8 x 5-3/8 x 3)
Units
MHz
dB
"
"
"
0 to 20dB, 2dB steps
Forward : 3 to 13dB
Reverse: 2 to 10dB in 2dB
steps
dBc
"
"
dBc
"
"
"
"
"
dB
nsec
"
"
dBc
"
Vac
Watts
degC
kg (lb)
cm(in)
LHA41RM_V1 July09

Advertisement

loading

Summary of Contents for Lindsay LHA Series

  • Page 1 5-65 MHz / 85-1000 MHz 90-240VAC LHA series CATV Distribution Amplifiers with active return are broadband indoor GaAs-PushPull, high output level distribution amplifiers designed for RF distribution systems such as those in Cable Television Apartments, Hotels, Hospitals and other applications where a high quality low noise figure amplifier is necessary to amplify the signals in both the forward and return paths.
  • Page 2: Block Diagram

    The exclamation point within an The Lightning flash with arrowhead symbol CAUTION equilateral triangle is intended to within an equilateral triangle is intended to alert you to the presence of alert you to the presence of uninsulated " important operating and dangerous voltage "...
  • Page 3 Instruction Manual LHA Series 1 GHz Ordering Information (LHA41RM-1GHz) Note Forward Equalizer Module All products are factory installed with 1 set of Diplex Filters (DF..), JXP Style – 1’’ EQL-1GHz-0xx 0dB Attenuator Pads(ATTxx) and 0dB Equalizer Modules (REQL XX: (Value in dB) : 3-5-7-9-11-13 and EQL, ) on the Reverse and Forward Paths.

This manual is also suitable for:

Lha41rm-1ghz (65/85)Lha41rm-1ghz (42/54)