Download Print this page
State Water Heaters Gas Specification Sheet
State Water Heaters Gas Specification Sheet

State Water Heaters Gas Specification Sheet

State water heaters gas, oil & dual fuel commercial water heaters specification sheet

Advertisement

Quick Links

Large Volume Power Burner: Gas, Oil & Dual Fuel Commercial Water Heaters
Limited Warranty Outline
– If the tank should leak any time during the first three years, under
the terms of the warranty, State Water Heaters will repair or replace
heater; installation, labor, handling and local delivery extra.
– NOTE: This Outline Is NOT A Warranty. For complete information,
consult the written warranty or State Water Heaters.
TPO – Oil Fired Models: No. 1 or 2 Oil
– Multi-annular fuel containment combustor head
– Available for firing light fuel oils including diesel
– Oil ignition transformer
– Integral 2-stage fuel unit
– Squirrel cage blower
– Oil safety valve
TPD – Dual Fuel Gas/Oil: Natural Gas or Propane & No. 1 or 2 Oil
– Multi-annular fuel containment combustor head
– Gas electric pilot and gas ignition transformer
– Pilot and main pressure regulators
– Air safety switch
– Manual fuel selector switch
– Integral 2-stage fuel unit
– Squirrel cage blower
500 Lindahl Parkway, Ashland City, TN 37015 • www.statewaterheaters.com
COMMERCIAL
The Expert's Choice
®
Meets or exceeds current edition of ASHRAE/IES-90.1-1999.
Low NO
– TPX Low NO
models meet or exceed current Texas and
X
X
California SCAQMD air quality standards.
UL – Entire unit UL listed (File No. MH11631).
Glass-Lined Tank – Exclusive corrosion protection with glass-
lining on all interior surfaces. Multiple anodes provide even more
corrosion protection.
ASME Construction Standard – 160 PSI working pressure on all models.
Powered Gas Burner – Powered burner has electronic flame
safeguard control with intermittent spark ignition. Also included are
main and pilot automatic gas valves plus gas pressure regulators,
diaphragm air switch for proof of blower operation.
– TPX Low NO
Models are factory standard with modulating fire.
X
The burner automatically adjusts the firing rate and the Btu output
to maintain precise system temperature control.
Fully Automatic Controls With Safety Shutoff – High temperature
limit control (manual reset). ASME rated temperature and pressure
relief valve. Hinged door control compartment for ease of access. Two
thermostats, upper and lower, for accurate temperature control.
Standard control is for 120˚F - 180˚F water service.
Jacket And Insulation – Heavy gauge steel with baked powder coat
finish. Insulated with high-density foam insulation that meets or
exceeds all required standards.
Professional Start-Up Service Furnished To Assure Most Efficient
Combustion And Safe Initial Start-Up.
Other Features
– Two layers of high temperature ceramic fiber insulation in
combustion chamber
– Flame inspection port opening
– Mounted on rugged channel iron skids
– Combination temperature and pressure gauge
– Low water cutoff
– ASME rated temperature and pressure relief valve
– Barometric draft regulator
– Two cleanout inspection openings
– 120 volt control circuit
– Drain valve
– Removable lifting lugs
Options
– Factory Mutual approved control arrangement
– Industrial Risk Insurance (IRI Gas Train)
– 5 year or 10 year limited warranty
– High or low water pressure switch
– 180°F water service thermostats
– A.G.A. rated T & P Valve
– Modular graphic burner systems management on heaters with
270,000 Btu input and over
– Combustion Air intake Adapter

Advertisement

loading

Summary of Contents for State Water Heaters Gas

  • Page 1 – Squirrel cage blower – Oil safety valve ■ TPD – Dual Fuel Gas/Oil: Natural Gas or Propane & No. 1 or 2 Oil – Multi-annular fuel containment combustor head – Gas electric pilot and gas ignition transformer – Pilot and main pressure regulators –...
  • Page 2 A negative draft of -0.02˝ to -0.07 is required in the vent. TPG models are available in both natural gas and propane. To order propane, change the “N” to “P” in the model number. Example: TPG 150 140 PEA 500 Lindahl Parkway, Ashland City, TN 37015 •...
  • Page 3 Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type “B” venting material is recommended. A negative draft of -0.02˝ to -0.07 is required in the vent.
  • Page 4 Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type “B” venting material is recommended. A negative draft of -0.02˝ to -0.07 is required in the vent.
  • Page 5: Specifications

    Category I negative draft appliances per the latest addition of the National Fuel Gas Code. An approved/listed Type “B” venting material is recommended. A negative draft of -0.02˝ to -0.07 is required in the vent.
  • Page 6: Suggested Specifications

    flame safeguard, intermittent ignition, main and pilot automatic gas valves, redundant solenoid gas valve, gas pressure regulator, diaphragm air switch for proof of blower operation, and flame inspection port. Maximum supply gas pressure to heater 13˝ W.C. Heater(s) shall have an input rating of ____________ and a recovery rating of ________ GPH at a temperature rise of 100°F with a minimum actual storage capacity of ________.

This manual is also suitable for:

Oil & dual fuel commercial water heaters