Download Print this page

Qlight S80R Quick Start Manual

Bulb revolving warning light

Advertisement

Quick Links

Bulb Revolving Warning Light
S80R/ S80U
90dB
20
50
44
Thank you for purchasing Qlight's products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to fire, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, fire, electric shock and loss of life.)
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the
product that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product's specification.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Ordering Specifications
S80U
-
BZ
-
[Model
[Buzzer]
number]
|
|
• S80R
• (Blank)
• 12 - DC12V
• S80U
- No buzzer type
• 24 - DC24V
• BZ
• 110 - AC110V
- Built-in buzzer
• 220 - AC220V
type
S80R
S80U
220
-
R
number
[Voltage]
[Color]
|
|
R-Red
A-Amber
G-Green
B-Blue
• Protection rating : IP44
• Ambient operating temperature : -20°C to +50°C
Please scan the QR
code for more detailed
product information.
www.qlight.com
Product Specifications
Model
Voltage
Current
Volts/
Watts
DC12V Max. 0.484A 12V5W
DC24V Max. 0.310A 24V5W
S80R
S80U
AC110V Max. 0.080A 12V5W
AC220V Max. 0.040A 12V5W
1
Bulb specifications
Certificate Weight
Configuration Part#
5
6
T16x35 15S
5
-
5
Color
0.28kg
R-Red
A-Amber
G-Green
B-Blue
0.48kg

Advertisement

loading

Summary of Contents for Qlight S80R

  • Page 1 3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to follow these instructions may lead to fire, electric shock, or product damage.) 4.
  • Page 2 Lens(AS) 3-Ø5 HOLES Ø10 HOLES Reflector (Heat resistant ABS) Light bulb PCD 50 S80R/ S80U Housing(ABS) Rubber spacer Flat washer Flange nut • First, remove the flange nuts from bolts and place the product through the mounting surface holes. • Fasten the flange nuts on the opposite side of the...
  • Page 3 • In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside- down positions where water can potentially penetrate into the product and impact it’s operation. • For further information, please visit our website (http://www.qlight.com). Product Operation Inquiry / Customer Support +82-55-328-4082 You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.