PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation, these instructions must be read carefully and understood.

TABLE OF CONTENTS

Product warranty ................................................ 1
1
About the manual..................................... 2
2
Introduction ............................................. 2
2.1 Features and specifications ........................ 2
2.2 Design ratings at max. and min.
operating temperatures .............................. 2
2.3 Application data ........................................... 2
3
confirmation ............................................ 2
3.1 Receiving inspection .................................... 2
3.2 User's rating inspection .............................. 2
4
Installation ............................................... 3
5
Operation ................................................. 3
5.1 Pre-operational check ................................. 3
5.2 Operating ...................................................... 3
6
Maintenance ............................................ 4
6.1 Preventative maintenance ........................... 4
6.2 Troubleshooting ........................................... 4
7
Disassembly - reassembly ...................... 4
8
Disposal at end of useful life ................... 4
9
Telephone assistance .............................. 5
10 Exploded parts drawing ........................... 5
Tables and figures
Table 1 - Design ratings at max. and min.
operating temperatures ................... 2
Table 2 - Troubleshooting ................................ 4
Figure 1 - Typical installation schematic
gas operated pumping gases ........... 3
Figure 2 - Typical installation schematic
steam operated pumping water ...... 3
Figure 3 - Exploded parts drawing ................... 5
Emerson.com/FinalControl

PRODUCT WARRANTY

Emerson warrants its Penberthy products
as designed and manufactured to be free
of defects in the material and workmanship
for a period of one year after the date of
installation or eighteen months after the date
of manufacture, whichever is earliest. Emerson
will, at its option, replace or repair any products
which fail during the warranty period due to
defective material or workmanship.
Prior to submitting any claim for warranty
service, the owner must submit proof of
purchase to Emerson and obtain written
authorization to return the product. Thereafter,
the product shall be returned to Emerson with
freight prepaid.
This warranty shall not apply if the product has
been disassembled, tampered with, repaired
or otherwise altered outside of the Emerson
factory, or if it has been subject to misuse,
neglect or accident.
The responsibility of Emerson hereunder
is limited to repairing or replacing the
product at its expense. Emerson shall not be
liable for loss, damage or expenses related
directly or indirectly to the installation or use
of its products, or from any other cause or
for consequential damages. It is expressly
understood that Emerson is not responsible
for damage or injury caused to other products,
buildings, personnel or property, by reason of
the installation or use of its products.
This is Emerson's sole warranty and in lieu of
all other warranties, expressed or implied which
are hereby excluded, including in particular all
warranties of merchantability or fitness for a
particular purpose.
This document and the warranty contained
herein may not be modified and no other
warranty, expressed or implied, shall be made
by or on behalf of Emerson unless made in
writing and signed by the company's general
manager or director of engineering.
© 2018 Emerson. All Rights Reserved.
VCIOM-04057-EN 19/04

Advertisement

loading

Summary of Contents for Emerson PENBERTHY GL

  • Page 1: Table Of Contents

    Disposal at end of useful life ....4 Telephone assistance ......5 This is Emerson's sole warranty and in lieu of 10 Exploded parts drawing ......5 all other warranties, expressed or implied which...
  • Page 2: About The Manual

    Under no circumstances should these design IMPORTANT ratings or application data be exceeded. Emerson does not have any control over the Exceeding design ratings or application data may manner in which its jet pump is handled, installed cause severe physical injury or property damage.
  • Page 3: Installation

    PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 4 INSTALLATION FIGURE 1 Typical installation schematic gas operated pumping gases Note: The user should refer to the relevant technical data sheet or product proposal to obtain dimensional information for the specific size and model of jet pump.
  • Page 4: Maintenance

    PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 6 MAINTENANCE 7 DISASSEMBLY - REASSEMBLY 8 DISPOSAL AT END OF USEFUL LIFE WARNING WARNING Penberthy jet pumps are used in a variety of Maintenance should only be undertaken by Do not proceed with removal of the jet pump fluid applications.
  • Page 5: Telephone Assistance

    Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Penberthy is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co.

This manual is also suitable for:

Penberthy gh