Download Print this page

HANYOUNG NUX PB-T10RN Instruction Manual

General purpose photo sensor

Advertisement

Quick Links

PB series
General Purpose Photo Sensor
INSTRUCTION MANUAL
Thank you for purchasing Hanyoung Nux products.
Please read the instruction manual
carefully before using this product, and use the product correctly.
Also, please keep this instruction manual where you can see it any time.

▍ Safety information

Please read the safety information carefully before use, and use the product correctly.
The alerts declared in the manual are classified into Danger, Warning and Caution according to their importance
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or property damage
CAUTION
DANGER
• The input/output terminals are subject to electric shock risk. Never let the input/output terminals come in contact with your body or
conductive substances.
WARNING
• This product is not for outdoor use (it may shorten the product lifetime and cause electric shock)
• Do not use this product in places with flammable or explosive gases (it does not have an explosion-proof structure, so there are fire
or explosion risks)
• Do not use the product in places where vibrations or shocks exceed the reference values (it has a double insulation
structure, but the components may be damaged)
CAUTION
• Never use it on AC power.
• Be careful of wiring. It may cause explosion, fire, or machine breakdown.
• Do not use the product in a state where the product body or
cable is crashed.
• Do not disassemble, repair or modify the product.
• When the lens of the photo sensor is contaminated by foreign
substances, use a dry piece of cloth and wipe off the
substance lightly. Never use thinner or organic solvents.
• Separate high voltage cable and power line from the sensor wire.
Be cautious since using the same pipe during wiring could cause
malfunction.
• If the cable needs to be extended, use over 0.3 ㎟ and be
cautious because of a possible sudden voltage drop.
• When using the sensor under lights with high frequency, such as
fluorescent lamps or mercury lamps, block it with a light
shading plate and avoid the lens from facing the light directly.
• Malfunction can occur due to mutual interference when using
▍ Suffix code
NPN
PB-T7N
PB-T10RN
Model
PNP
PB-T7P
PB-T10RP
Sensing
Through-beam
mode
Sensing distance
7 m
10 m
Hysteresis distance
Detecting object
Opaque Ø12 mm or more
Light source
IR(860nm) RED(640nm) IR(860nm)
(wavelength)
Emitter: max. 20 mA,
Current consumption
Receiver: max. 20 mA
Power voltage
Control output
▪ Load current - max. 100 mA (26.4 VDC standard)
▪ Residual voltage - NPN: max. 1 V, PNP: max. 1 V
Operation mode
Power reverse connection protection, Output reverse connection protection,
Common
Protection
Output short-circuit over-current protection, Output short-circuit alarm (Note 2)
circuit
Individual
Response time
Insulation Resistance
Noise immunity
Square wave noise by noise simulator (pulse width 1 s) ± 240 V
Dielectric strength
Vibration resistance
10 - 55 Hz, Double amplitude : 1.5 mm, X·Y·Z 2 in each direction for 2 hours
Shock resistance
Ambient illumination
Sunlight : max. 11,000 lx / Incandescent: max 3,000 lx
Ambient temperature
During operation : -25 ~ +55 ℃, During storage : -40 ~ +70 ℃ (Without condensation or icing)
Ambient humidity
Degree of protection
Certification
Case
Material
Display
Lens
Common
Accessory
Individual
Optional
Weight
Approximately 90g
(※Note 1) When using HY-M5S 0.1 to 4 m
(※Note 2) Red LED flashes in case of overload. (ON Time: 200 ㎲, OFF Time: 40 ㎲)
▍ Output circuit
※ Diffuse-reflective, distance-settable, retro-reflective, receiver of through-beam types only
NPN TYPE
NPN TYPE
(however, the emiiter of through-beam type has 12 - 24 VDC power input only.)
■ NPN TYPE
1.2
Brown (BRN)+V
Load
Black
(BLK)OUT
100 mA Max.
Overcurrent
protection
circuit
Blue (BLU) 0 V
Internal circuit
External connection example
HANYOUNGNUXCO.,LTD
28, Gilpa-ro 71beon-gil,
Michuhol-gu, Incheon, Korea
TEL : +82-32-876-4697
http://www.hynux.com
more than 2 pairs of through-beam type photo sensors. Therefore,
leave enough space for the mutual separation distance and install
the light emitters and the light receivers in alternating positions.
• Using inductive load (relay, coil) for the output can cause an
instantaneous increase in load by more than two times and damage
the TR of the output. Therefore, please set half of the maximum load.
• There is an over-current protecting circuit within the output side
that breaks the output when the current is higher than the rated
load current. Therefore, please set within 70% of the maximum load.
• Do not use the product in places with heavy dust or debris that
can contaminate the lenses and consequently cause malfunctions.
• The contents of this manual may be changed without prior notification
• Any use of the product other than those specified by the
manufacturer may result in personal injury or property damage.
• When using the Switching Power Supply as power source,
ground the Frame Ground (F.G.) terminal and be sure to connect
the noise-cancelling condenser between OV and F.G. terminals
PB-T15N
PB-M3RN
PB-R01N
PB-R04RN PB-R1N
PB-T15P
PB-M3RP
PB-R01P
PB-R04RP PB-R1P
Retroreflective
Diffuse-reflective
(mirror)
0.1 ~ 3 m
15 m
0.1 m
0.4 m
(※Note 1)
20% or less of detection distance
Ø75 mm
White non-glossy paper (100 x 100 mm)
more (Opaque)
RED(640nm)
IR(860nm) RED(640nm) IR(860nm)
Max. 30 mA
12 - 24 VDC ±10 % (Ripple max. 10 %)
NPN or PNP open collector output
Light ON / Dark ON switch
Mutual interference prevention function
1 ms or less
More than 20 MΩ (500 VDC mega)
1,000 VAC (50/60 Hz for 1 minute)
500
, X·Y·Z each direction 3 times
35 ~ 85 % RH (Without condensation)
IP65 (IEC standard)
PBT GF30 %
PC
PC
Brackets A, volt (M3 X 12 mm), Volume driver
Mirror (HY-M5)
29
Brackets B, Brackets C, Mirror (HY-M5S)
4.5
Approximately
Approximately 50g
60g
6
NPN TYPE
22.23
NPN TYPE
16
1.2
■ PNP TYPE
Brown (BRN)+V
100 mA Max.
Overcurrent
protection
Black
circuit
(BLK)OUT
12 - 24
VDC
Blue (BLU) 0 V
Internal circuit
External connection example
▍ How to set sensitivity and operation mode
■ Sensitivity adjustment
- min. rotation direction (counterclockwise): Minimum sensitivity
- max rotation direction (clockwise): Maximum sensitivity
■ Operation mode
- D rotation direction (counterclockwise): Dark ON mode
- L rotation direction (clockwise): Light ON mode
※Turn the volume switch all the way
MK2101KE181126
when switching modes.
▍ Motion chart
Operation mode

▍ How to install

PB-D04N
PB-D04P
Distancesettable
1 m
0.4 m
IR(860nm)
▍ Accessory
■ Bracket A
36
6
6
6
6
25.4
14
14
■ Bracket C (sold separately)
12 - 24
VDC
Load
Sensitivity
adjustment volume
Operating mode
switching volume
※However, the emitter has one red power indicator at the center
Stable Light ON area
Unstable Light ON area
Unstable Dark ON area
Stable light Dark ON region
Operation indicator
Light ON
Output
Stability indicator
Operation indicator
Dark ON
Output
Stability indicator
▍ Dimensions
Brackets B
M3 X 12mm
Tightening torque should
be max. 0.5N.m
36
6
6
6
6
3.5
25.4
3.5
1.2
1.2
5
6
13
36
9.5
21
Stability indicator
Operation indicator
unit : mm
2-M3 TAP
20
3.8 Ø
12
■ Bracket B (sold separately)
29
29
4.5
4.5
6
6
22.23
22.23
16
1.2
16
■ Mirror HY-M5, HY-M5S (sold separately)
40.3
34
7.5
7.0
2-Ø3.5
1.6
2.7
■ Volume driver
5.5
1.2

Advertisement

loading

Summary of Contents for HANYOUNG NUX PB-T10RN

  • Page 1: Safety Information

    28, Gilpa-ro 71beon-gil, Michuhol-gu, Incheon, Korea - D rotation direction (counterclockwise): Dark ON mode TEL : +82-32-876-4697 Thank you for purchasing Hanyoung Nux products. - L rotation direction (clockwise): Light ON mode Operation indicator http://www.hynux.com Please read the instruction manual Sensitivity carefully before using this product, and use the product correctly.
  • Page 2 • 투과형 포토 센서를 2조 이상 사용할 경우 상호 간섭으로 오동작 단위:mm 할 수 있으므로 상호 이격 거리를 충분히 띄워 주시고 투광기와 수광기의 위치를 엇갈리게 설치하여 주십시오. 2-M3 TAP ▍ 정격 / 사양 브라켓 B M3 X 12mm PB-T7N PB-T10RN PB-T15N PB-M3RN PB-R01N PB-R04RN PB-R1N PB-D04N 체결 토크는 형명...

This manual is also suitable for:

Pb-t7nPb seriesPb-m3rnPb-t15nPb-r01nPb-r04rn ... Show all