ITEMS
1
Nominal Output Voltage
2
Maximum Output Current
3
Nominal Output Power
4
Efficiency (Typ.)
5
Input Voltage Range
6
Input Frequency
7
Input Current
8
Power Factor
9
Output Voltage Accuracy
10 Output Voltage Range
11 Maximum Ripple & Noise
12 Maximum Line Regulation
13 Maximum Load Regulation
14 Over Current Protection
15 Over Voltage Protection
16 In-rush Current (Typ.)
17 Parallel Operation
18 Series Operation
19 Operating Temperature
20 Operating Humidity
21 Storage Temperature
22 Storage Humidity
23 Cooling
24 Temperature Coefficient
25 Withstand Voltage
26 Isolation Resistance
27 Vibration
28 Shock
29 Safety
30 Weight (Typ.)
31 Size (W x H x D)
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100VAC/200VAC and maximum output power.
(Baseplate Temperature = +25°C.)
*2. For cases where conformance to various safety specs
(UL, CSA, EN) are required, input voltage range
will be 100 - 240VAC(50 - 60Hz).
*3. Ratings - refer to Derating Curve on the right.
*4. Heatsink has to be chosen according to Instruction manual.
*5. External components are needed for operation.
(Refer to basic connection and instruction manual.)
*6. First inrush current. Not applicable for the inrush current to
Noise Filter for less than 0.2ms.
*7. Refer to Instruction manual.
*8. Ambient Temperature min=-40°C.
*9. Start-up at Vin=83VAC guaranteed.

SPECIFICATIONS

MODEL
PFE300SA-12
V
A
W
300
%
84 / 85
(*1)
-
(*2)(*5)(*9)
Hz
(*2)
A
3.8 / 1.9
(*1)
-
(*1)(*5)
%
(*1)
%
mV
120
(*5)
mV
mV
-
-
A
(*1)(*5)(*6)
-
-
(*7)
-
(*3)(*8)
-
-
-
-
(*4)
-
-
Input-Baseplate : 2.5kVAC, Input-Output : 3.0kVAC for 1min.
-
Output to Baseplate 500VDC more than 100MW (25°C,70%RH)
-
Amplitude 0.825mm Constant (Maximum 49.0m/s
-
-
g
mm
PFE300SA-28
12
28
25
10.8
302.4
87/ 89
85 - 265 VAC
47 - 63
3.7 / 1.8
0.95 min
+/-2
-20 / +20
280
48
56
48
56
105% - 140% (Automatic recovery method)
125% - 145% (Inverter shutdown method)
20A / 40A peak
Possible
-40°C - +100°C
20 - 95%RH (No Dewdrop)
-40°C - +100°C
10 - 95%RH (No Dewdrop)
Conduction Cooled
Less than 0.02% / °C
Output-Baseplate : 1.5kVDC for 1min.
At No Operating, 10-55Hz (Sweep for 1min.)
196.1m/s
Approved by UL60950-1,CSA60950-1,EN60950-1
200
61 x 12.7 x 116.8 (Refer to Outline Drawing)
Derating Curve
100
80
60
40
20
0
-40
-20
TDK-Lambda
PFE300SA-48
48
6.3
302.4
88 / 90
3.6 / 1.8
480
96
96
-
2
) X,Y,Z 1 hour each
2
0
20
40
60
80
Baseplate Temperature (℃)
100

Advertisement

loading

Summary of Contents for TDK-Lambda PFE300SA-28

  • Page 1: Specifications

    TDK-Lambda PFE300SA C274-01-01A SPECIFICATIONS MODEL PFE300SA-12 PFE300SA-28 PFE300SA-48 ITEMS Nominal Output Voltage Maximum Output Current 10.8 Nominal Output Power 302.4 302.4 Efficiency (Typ.) 84 / 85 87/ 89 88 / 90 (*1) Input Voltage Range 85 - 265 VAC (*2)(*5)(*9)
  • Page 2 TDK-Lambda PFE300SA C274-01-02 BASIC CONNECTION AC250V 15A 1000pF AC250V 1uF (Film) 12V: 25V 1000uF (Elec.) 4700pF 28V: 50V 470uF (Elec.) 4700pF 48V: 100V 220uF (Elec.) AC250V 1uF (Film) 100V 2.2uF (Ceramic) AC250V 1uF (Film) 12V: 25V 1000uF (Elec.) 1000pF 28V: 50V 470uF (Elec.) 1000pF 48V: 100V 220uF (Elec.)

This manual is also suitable for:

Pfe300sa-12Pfe300sa-48