Firepower Klover Bi-Fire Mid Operation And Maintenance

Advertisement

Quick Links

Bi-Fire, Bi-Fire Mid,
Bi-Fire Utility
Operation and Maintenance

Advertisement

loading

Summary of Contents for Firepower Klover Bi-Fire Mid

  • Page 1 Bi-Fire, Bi-Fire Mid, Bi-Fire Utility Operation and Maintenance...
  • Page 2 Klover Bi-Fire series – Operation and Mainteance This information leaflet must be read in conjunction with your Operation and Installation Manual. Introduction Your Klover Bi-Fire combined wood and pellet boiler should give you years of trouble free heating but there are certain things that you as the user need to do to keep the stove running cleanly and efficiently.
  • Page 3 needed and can cause problems with your appliance. Bear in mind that EN+A1 pellets are not all the same so it can be worth trying out different makes. Loading the boiler with logs It is very important that you burn only dry, well-seasoned wood (with a moisture content of 25% or lower) to get a good heat from your Bi-fire and ensure that you don’t build up tar residues in the stove and chimney.
  • Page 4 6. Clean the inside of the glass. On a less regular basis you will need to: 1. Remove the plate under the ash pan and vacuum under there – be careful not to damage the fan blades with the vacuum cleaner nozzle. 2.
  • Page 5 If you let the hopper run out of pellets then the display will read AL 6 – NO PELL. ALARM. The first things to do are fill up the hopper and check that the crucible is clean. If there are pellets in the crucible then empty it (not into the hopper) and check that the holes are clear.