Download Print this page

AARC Systems EVAC ARX43E52 Installation & Operation Manual

Indoor standalone wireless linked message player & message player/repeater units

Advertisement

Quick Links

AARC-EVAC Indoor Standalone
Wireless Linked Message Player
& Message Player/Repeater Units
Installation & Operation Manual
Components Supplied
2 Speaker
1 x ARX43E52
Message Player Unit
OR
1 x ARX43E52R Message Player/
Repeater Unit
1 x 15 VDC Power Supply
2 x 15 Watt Speakers*
1 x AARC Antenna
*A combination of Horn and Box Speakers as required.
The AARC-EVAC Wireless Emergency and S.O.S. Assist
Message Player is a standalone system incorporating a
backup battery system. The Message Player/Repeater is the
same as above plus incorporates a signal repeater.
A wireless radio linked signal from a system Alert Panel or a
wireless Signal Repeater unit triggers standard emergency
alert sirens, a lockdown message and up to 7 unique S.O.S.
assistance zoned messages.
Audio outputs include standard emergency alert sirens
including "Alert" and "Evacuation". "Evacuation" also includes
and if applicable a "Lockdown" message.
"Alert" activation outputs the Australian Standard alert tone
(complying to AS1670.4). Units can be ordered with 2 options:
1) Alert will continue until cancelled.
2) Unit can be factory set to sound for between 1–255
seconds and if not cancelled before the set time, the unit
will automatically trigger the Evacuation Alert.
"Evacuation" activation outputs the Australian Standard
evacuation tone (complying to AS1670.4). To comply with
Australian Standards for evacuation tones, a custom message
aarcsystems.com
3 Speaker
1 x ARX43E53
Message Player Unit
OR
1 x ARX43E53R Message Player/
Repeater Unit
1 x 15 VDC Power Supply
3 x 15 Watt Speakers*
1 x AARC Antenna
4 Speaker
1 x ARX43E54
Message Player Unit
OR
1 x ARX43E54R Message Player/
Repeater Unit
1 x 15 VDC Power Supply
4 x 15 Watt Speakers*
1 x AARC Antenna
may be played after every third cycle providing evacuation
instructions to occupants. Voice message could be
something like "please evacuate the building by the closest
exit and assemble at the designated assembly point".
If used, "Lockdown" activation outputs an audio custom
message to suit your application, chimes, tones, music
track or voice message or any combination thereof.
Up to 7 unique "S.O.S" zoned messages can also be
triggered. (e.g. "[ding...dong] assistance to front desk" etc.)
Multiple Alert Panel transmitters can be used within the
same "S.O.S." zones, if required. Multiple message
message player units can be used within the same system
to increase the coverage area. A wireless "Cancel" activation
(hidden button located on transmitters with "Lockdown"
function) will stop any of the alerts and reset the system.
Alternatively, Standalone Message Player units can also
be used in conjunction with the rack mount PA System
covered by the PA System. (Note: An adequately-sized UPS
is always recommended to power the PA system in case of
mains failure.)

Advertisement

loading

Summary of Contents for AARC Systems EVAC ARX43E52

  • Page 1 AARC-EVAC Indoor Standalone Wireless Linked Message Player & Message Player/Repeater Units Installation & Operation Manual Components Supplied 2 Speaker 3 Speaker 4 Speaker 1 x ARX43E52 1 x ARX43E53 1 x ARX43E54 Message Player Unit Message Player Unit Message Player Unit 1 x ARX43E52R Message Player/ 1 x ARX43E53R Message Player/ 1 x ARX43E54R Message Player/...
  • Page 2 AARC-EVAC Wireless Alert Transmitters Installation & Operation Manual Installation Diagram Plastic Screw Locks Speaker Connection SPK1 Speaker Connection SPK2 Speaker Connection SPK3 (if applicable) Speaker Connection SPK4 (if applicable) Speaker Volume Control SPK1 Speaker Volume Control SPK2 Speaker Volume Control SPK3 (if applicable) Speaker Volume Control SPK4 (if applicable) 1 of 4 Wall Mounting holes, these are pre-drilled.
  • Page 3 AARC-EVAC Wireless Alert Transmitters Installation & Operation Manual Installation Instructions 1. Removing Front Cover pushed on the Alert Panel the Red Light will come on and stay on while button is pushed. turning anti clockwise quarter of a turn from “1” to “0” as indicated on front cover embossed around individual screws.
  • Page 4 AARC-EVAC Wireless Alert Transmitters Installation & Operation Manual Maintenance Guide to Setting Sound Levels The UPS Battery condition should be checked regularly for correct Precheck the normal background noise level (the Base noise level) in operation. This can be done by observing the battery condition indicator each area to be covered by the AARC-EVAC system.

This manual is also suitable for: