1-CHANNEL, ASTRONOMICAL DIGITAL TIME
PROGRAMMER ZCM-31, ZCM-31P/U
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamel.com, e-mail: marketing@zamel.pl
DESCRIPTION
TECHNICAL DATA
ZCM-31 digital time programmers are
used to realize time functions in automa-
tion and control systems. Switching on /
switching off the device is related to sun-
set and sunrise (official dawn and dusk).
The following information on geographic
coordinates of the clock's installation
place, current date, and time difference
with regard to the universal time (GMT)
is used to calculate the time of sunrise
and sunset. The system calculates the
so-called official time of sunrise and sun-
set and this is the phase when the upper
edge of the Sun touches the horizon. Ad-
ditionally, the system has the function of
a programmable night break and a pos-
Cooperation with external memory: ZCM-31: no
sibility to change the calculated sunrise/
sunset time in the range of ±120 min.
The device casing construction allows
the system to be installed on a TH35 rail
and additionally the casing can be sealed.
The system structure guarantees battery
backup of the settings in case of power
supply failure.
CAUTION:
Cross-section of connection cables: 0,2 ÷ 2,50 mm²
To protect the programmer's battery
during storage time, the ZCM-31 series
has a 'storage mode' default setting
with a minimum current consumption.
FEATURES
● control depending on current time in the
astronomical cycle,
● double modular casing with a protective
cover,
APPEARANCE**
● IN control input,
● LCD with backlight,
● mounting on a TH35 rail.
Input (supply) terminals:
The device is designed for sin-
(A1, A2)
gle-phase installation and must be in-
stalled in accordance with standards
valid in a particular country. The de-
CAUTION!
vice should be connected according
to the details included in this manual instruction.
Installation, connection and control should be
LCD
carried out by a qualified electrician staff, who
act in accordance with the service manual and
the device functions. In case of casing disman-
tling, the guarantee is lost and an electric shock
may occur. Before installation make sure the
connection cables are not under voltage. Im-
External memory*
proper transport, storage, and use of the device
influence its wrong functioning. It is not advis-
able to install the device in the following cas-
Control push buttons
es: if any device part is missing or the device
is damaged or deformed. In case of improper
functioning of the device contact the producer.
The symbol means selective collecting of elec
Relay output terminals
trical and electronic equipment. It is forbidden to
(12, 11, 14)
put the used equipment together with other waste.
* not applicable to ZCM-31
** applicable to ZCM-31P/U
MANUAL INSTRUCTION
ZAMEL Sp. z o.o.
Input (supply) terminals: A1, A2
Nominal supply voltage: ZCM-31: 230 V AC~(-15 ÷ +10 %)
ZCM-31P/U: 24 ÷ 250V AC, 30 ÷ 300 V DC
Nominal frequency: 50 / 60 Hz
Nominal power consumption: ZCM-31: 1,5 W / 16 VA – stand-by
/ switched on relay
ZCM-31P/U: 0,8 W / 1,4 VA – stand-by
ZCM-31P/U: 1,5 W / 2,9 VA - switched on relay
Number of channels: 1
Programme: astronomical (official dawn and dusk)
Operation modes: manual, automatic
Summer/winter time change: automatic, manual
LCD backlight colour: amber
External input: yes
ZCM-31P/U: yes
Time measuring accuracy: max. ± 1 s / 24 h for 25°C
Clock battery backup: 3 years
Programme battery backup: 10 years
Input (release) terminals: IN, IN, IN, IN
Output (load) terminals: 11, 12, 14
Relay contact parameters: 1 NO / NC 16 A / 250 V AC1 4000 VA
Number of connection terminals: 12
Operating temperature range: -20 ÷ +60°C
Operating position: free
Casing mounting: TH35 rail (acc. to EN 60715)
Casing protection degree: IP20 (EN 60529)
Protection class: II
Overvoltage category: II
Pollution degree: 2
Dimensions: double modular (35 mm) 90 x 35 x 66 mm
Weight: 0,17 kg
Reference standard: EN 60730-1; EN 60730-2-7,
EN 61000-4-2,3,4,5,6,11
Input (release) terminals:
(IN, IN, IN, IN)
Day of the week
Relay mode
Information field / date
Current time (hh:mm:ss)
Daytime / Night time
The symbol means selective collecting of
electrical and electronic equipment.
It is forbidden to put the used equipment
together with other waste.
plik: inst_ext_en_zcm-31_31PU | modyfikacja: 06.04.2016
DESCRIPTION
STORAGE MODE
• • The ZCM-31 programmers have a 'storage mode' default setting to protect the battery during storage.
• • During battery backup operation, the first programmer activation is realised by means of pressing the ( ) button shortly which causes the storage mode is
changed, next it is required to set the date and time.
• • During rated voltage operation, the first programmer activation is realised by setting the time and date.
• • The programmer can be readjusted to the storage mode by means of carrying out a device reset
• - in order to do it press the ( ) and ( ) buttons simultaneously for a shorter time in the main menu.
MAIN MENU
Automatic mode
Manual mode
OPERATION MODE CHANGE (AUTOMATIC, MANUAL)
Winter time
* not applicable to ZCM-31
** applicable to ZCM-31P/U
Description of elements and messages displayed
- days of the week
- relay mode
- automatic mode
- manual mode
- winter time
- summer time
- external input
- day
- year
- night break setting
- time correction setting
- current time setting and summer / winter time change
- current date setting
Description of buttons
• in the main window - enter the automatic mode;
• in other windows – go up one level without saving the entered data;
• in the main window – enter the manual mode or change the relay mode if the clock is in the manual mode;
• in other windows - go up one level without saving the entered data;
• in the main window –enter the main menu;
• in other windows – enter the submenu or confirm the settings;
• switching between windows / menu options or increasing /decreasing the pre-set parameters;
• right cursor ( ) in the main menu – sunrise and sunset time display.
**
Function
Description
NIGHT BREAK SETTING
SUNRISE / SUNSET TIME CORRECTION SETTING
CURRENT TIME SETTING
CURRENT DATE SETTING
SUMMER / WINTER TIME SETTING
GEOGRAPHICAL POSITION AND TIME ZONE SETTING
EXTERNAL INPUT SETTING
EXTERNAL MEMORY SETTING**
CALCULATED SUNRISE TIME
CALCULATED SUNSET TIME
MODE CHANGE INTO MANUAL - if the system is in the main window and the automatic mode ( ) is active,
press the ( ) button to change the system into the manual mode with a simultaneous change of the relay
mode;
Subsequent pressing of the ( ) button causes the relay switches to the opposite mode, but the operation
mode does not change;
MODE CHANGE INTO AUTOMATIC - if the system is in the main menu and the manual mode is active,
press the ( ) button to change the system into the automatic mode with a simultaneous change of the
relay mode.
- geographical position setting
- external input setting
- external memory operation **
- write to external memory **
- read from external memory **
- external memory usage**
- reading / saving error**
/
- sunrise / sunset time
/
- latitude / longitude
- automatic,
- user
- switched on /switched off
Press OK to enter from the main menu to the
menu; use cursors (
) to move in the menu.
It is possible to enter the main menu again by
pressing the ( ) or ( ) button. From the main
window you can also enter windows displaying
the calculated sunrise/sunset time by pressing
the ( ) cursor. Return is automatic after 10 s.

Advertisement

loading

Summary of Contents for Zamel Exta ZCM-31P/U

  • Page 1 - external input setting - automatic mode - external memory operation ** - manual mode - write to external memory ** ZAMEL Sp. z o.o. - winter time - read from external memory ** - summer time - external memory usage**...
  • Page 2 NIGHT BREAK SETTING WINTER / SUMMER TIME SETTING – setting the time of a night break; press OK to enter the setting view; by means of ) cursors choose the time to be changed whereas: The start time of the night break; press OK to enter the edition mode, The end time of the night break;...
  • Page 3 008:38:00 °E UK Southampton 50:55:00 °N 001:23:00 °E required for the product functioning, d) damage caused by Act of God or any other incidents independent of the manufacturer – ZAMEL Sp z o.o. Ireland Waterford 52:15:00 °N 007:06:00 °E Ukraine Kiev 50:28:00 °N...

This manual is also suitable for:

Exta zcm-31