Occupancy Sensor- Ceiling Mounted
[Mx-
]
EOSC
Package Contents:
- Occupancy Sensor.
- 2 screws, 2 wall anchors.
- Wire bracket.
Product Description:
The Magnum ceiling-mounted Occupancy Sensor saves energy and adds convenience
by accurately detecting when an area is occupied or vacant.
It is a wireless, solar-powered sensor that detects occupancy using passive infrared
(PIR) heat and motion sensing. The sensor transmits RF messages to Magnum lighting,
HVAC, and outlets to use energy more efficiently.
Features Include:
• Sends wireless messages to other devices whenever motion is detected
• Harvests ambient solar energy to power the sensor and wireless communication
• Mounts easily on any ceiling material
• Works with other sensors for enhanced occupancy tracking
• Built-in tests to confirm operation at installed location
• Supplemental battery option for extreme low-light fail-over
PLANNING:
Take a moment to plan for the sensor's successful operation and optimal communication with other system components. Remove the sensor from its packaging and place it in a strong light to
provide the required startup charge. (Tip: To quickly ensure the sensor energy storage is fully charged, insert a CR2032 battery for 30 seconds.)
• Ensure the location provides consistent and adequate light
• Locate the sensor in the center of the room with an unobstructed view of the space
• Avoid installed near ceiling fan or hanging fixtures
• Consider the area's traffic patterns and principal use, for example, walking, lounging or sleeping
Magnum Innovations
5675 Hudson Industrial Pkwy, Suite 3 -
Tools Required:
- Power drill, 3/16" bit.
- Screwdriver.
- Light meter.
- Battery (CR2032) for testing.
Proudly Made
In America
Hudson, OH 44236 -
phone 330.915.2382 - fax 330.529.5279 - www.magnum-innovations.com - info@magnum-innovations.com
SPECIFICATIONS:
Part Numbers (Frequency
M9-EOSC (902 MHz - North America)
Dependant)
M8-EOSC (868 MHz - Europe and China)
MJ-EOSC (928 MHz - Japan)
Power Supply:
Indoor light energy harvesting
Optional:
Supplemental battery (CR2032)
2-wire connector for external power or remote
solar cell (3-5 VDC)
RF Transmission Range
80 ft. (25 m)
Motion Sensing Range
40 ft. (12 m) diameter
(refer to coverage diagrams)
Startup Charge Times*
(operation from empty energy storage)
First motion transmission
5 minutes @ 200 lux
/ Linking
Motion LED blink
1.5 hours @ 2000 lux
Light Test / Walk Test
Sustaining Charge Time for
3 hours per 24 hours @ 200 lux
battery free operation
Time to Full Charge*
25 hours @ 200 lux
Operating Life in Total
80 hours
Darkness
(after full charge)
Minimum Operating Light
50 lux (for auto-off only)
Optional Battery Life:
• Infrequent Bright Light
20 yrs (with 200 lux for 2 hrs/day, 7days/week)
• Consistent Low Light
15 yrs (with 65 lux for 5 hrs/day, 7 days/week)
• Total Darkness
6.5 yrs
Motion Transmission Interval
2 minutes
Unoccupied Transmission
10 and 30 minutes since last motion
Heartbeat Transmission
Disabled by default
Interval (unoccupied)
Enabled = heartbeat @ 1 hr interval
(after unoccupied messages)
EnOcean Equipment Profile
A5-07-01 (EEP)
Dimensions
6.30" L x 2.35" W x 1.47" D
(160 mm x 60 mm x 37 mm)
Weight
4.4 oz. (125 g)
Mounting Height
7-10 feet (2-3m) recommended
Environment
Indoor use only
14° to 104°F (-10° to 40°C)
20% to 95% relative humidity
(non-condensing)
Agency Compliance
FCC, IC, RoHS, CE, R&TTE
*Natural bright light (2000 lux) or a battery can be temporarily used to significantly shorten startup charge
times. Specified lux values are for a typical fluorescent lighting. Lux level requirements for LED and other
types may vary. For lux reference, OSHA standards require a minimum of 323 lux for office areas.
• Confirm a location is suitable by temporarily mounting the sensor and testing
it, see Walk Test and Light Test sections
• Consider the construction materials in the space and obstacles that may
interfere with RF signals

Advertisement

loading

Summary of Contents for Magnum M9-EOSC

  • Page 1 6.30” L x 2.35” W x 1.47” D It is a wireless, solar-powered sensor that detects occupancy using passive infrared (160 mm x 60 mm x 37 mm) (PIR) heat and motion sensing. The sensor transmits RF messages to Magnum lighting, Weight 4.4 oz. (125 g) HVAC, and outlets to use energy more efficiently.
  • Page 2 Insert the first screw loosely and level the mounting plate. d. Insert the second screw and then hand-tighten the first screw. Magnum Innovations 5675 Hudson Industrial Pkwy, Suite 3 - Hudson, OH 44236 - phone 330.915.2382 - fax 330.529.5279 - www.magnum-innovations.com - info@magnum-innovations.com...
  • Page 3 (switching a light on or off for example). Transceivers can be linked to transmitters as well as other transceivers. A Magnum transceiver can have up to 30 devices linked to it. The Occupancy Sensor is a Transmitter To link devices, the transceiver must first be powered, within the transmission range, and set to accepts links using the 2-button interface on the transceiver.
  • Page 4 (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Magnum Innovations 5675 Hudson Industrial Pkwy, Suite 3 - Hudson, OH 44236 - phone 330.915.2382 - fax 330.529.5279 - www.magnum-innovations.com - info@magnum-innovations.com...

This manual is also suitable for:

M8-eoscMj-eosc