Page 1
Gas concentration above the threshold level triggers visual and audible alarm signals. The detectors are intended to used as part of a security system. The DG-1 series of digital gas detectors includes the following products: DG-1 CO – carbon monoxide detector;...
Page 2
DG-1 SATEL COM – common ground – power supply input 2 – LED indicator. Indicates by blinking activation, trouble and alarm of the detector. Depending on the detector type, the following LED colors are used: - red – DG-1 CO (sensor type TGS2442) - green –...
Page 3
SATEL DG-1 3. Installation and commissioning The DG-1 digital gas detectors are designed for indoor installation. Considering specific character of the gases to be detected, the DG-1 TCM and DG-1 LPG detectors should be mounted in low position, just above the floor, the DG-1 ME detector in high position, just under the ceiling, and DG-1 CO detector at a height of about 1.5 meter.
Page 4
DG-1 SATEL Fig. 3. Alignment of the matchmarks when closing the detector housing. 4. Technical data Nominal supply voltage (±15%) ................... 12 V DC Current consumption, standby: DG-1 CO ............. 9-20 mA DG-1 LPG ............30-50 mA DG-1 ME ............30-50 mA DG-1 TCM ............