  • Page 1 Solid Fuel Heating Unit Types FHSPN35 and FHSPN70 INSTRUCTION MANUAL...
  • Page 2 1. General information additional burner - pellets) directly from the heat exchanger tube to the outside environment, The Original Instruction Manual constitutes an without any intermediate liquid. During integral and material part of the product, and is to be combustion, smoke and other gases are transferred to the user with the transfer of generated, which are ventilated by the chimney ownership.
  • Page 3 The NPS series heater is not a furnace for burning waste, and fuel that is forbidden may not be burned in it. NOTE! Permanent use of certain wet fuel types, with FHSPN 35 FHSPN 70 Air heater simultaneous maintenance of low combustion Rated power...
  • Page 4 Ventilation HINT! The heater should be transported in a vertical It is forbidden to use forced ventilation in the position! installation room of the heater, taking in air for combustion from its room, and with a gravitational FHSPN series heaters may be stored in unheated combustion gas removal, and in the room in which rooms that are necessarily covered with a roof and the intake ducts for the combustion gas lines are...
  • Page 5  formula was devised that enables one to choose a for combustible materials with a flammability heater properly. rating of C3, which burn away quickly and easily even after the flame source is P = [qv W (tw - tz)] 0.001 removed, this distance increases twofold, i.
  • Page 6 The electric grid, to which the heater shall be connected, should terminate in an earthed socket. Grid voltage values required by the heaters Heater FHSPN35 FHSPN70 Minimum chimney height (m) FHSPN 35 230 V / 50 Hz Dimensions (cm x cm) 18x18 25x25 FHSPN 70...
  • Page 7 Where: HINT! F - chimney cross-section (sq m) The conclusion of installation and the Q - heater thermal capacity (kW) execution of a heating trial need to be noted in h - height of chimney measured from the burner the warranty card. The completed warranty level to the exit (m) card should be sent by the user, as copy, to the address of the manufacturer so the user is...
  • Page 8 NOTE! Components of the heater - in particular outer covers - are hot during operation. Appropriate caution is advised! NOTE! Never stand straight before the boiler when In the grid chamber of the heater, pay particular opening doors. Risk of burns! attention to the precise removal of ash and slag from the grid grooves and chamber walls.

This manual is also suitable for:

Fhspn 70