Download Print this page

VDH ALFA 801 User Manual

Pulse/pause timer-unit

Advertisement

Quick Links

VDH doc. 060344
Software: ALFA 801 Flash
* Operation.
The ALFA(NET) 801 is a panel mounting timer-unit, with a pulse/pause relay function. The pulse and
pause time are set by parameters (P01 and P02). The timer-unit has a range from 0-999 minutes or
seconds (P03). The timer-unit has also a contact-input for starting the unit with pulse or pause (P05).
The ALFANET 801 is provided with a RS 485 network connection, to readout or set the unit on the PC
with ALFANET software. by using a ALFANET PC-Interface.
* Installation.
On the topside of the ALFA(NET) 801 can be read how to connect this unit, such as powersupply,
relay-output, contact input and network.
After power up the ALFA(NET) 801 and the self test is finished the unit displays the pulse or pause
time. As the output relay is activated the LED 'on' in the display lits to indicate this.
* Control.
The ALFA(NET) 801 Timer-unit can by controlled by three pushbuttons on the front. These keys are:
[] SET
- view / change setting.
[] UP
- increase setting.
[] DOWN - decrease setting.
* Changing current pulse/pause time.
Push the SET key, the LED 'set' starts blinking. Release the SET key. Now push the SET key again
and together with the UP or DOWN keys the current pulse or pause time can by changed. A few
seconds after releasing the keys the timer-unit returns to it's normal operation, the LED 'set' switches
off.
User manual
ALFA 801 and ALFANET 801
Pulse/pause Timer-unit
Version: v1.0
File: Do060344.wpd
1
Date: 02-02-2006
Range: 0-999

Advertisement

loading

Summary of Contents for VDH ALFA 801

  • Page 1 User manual ALFA 801 and ALFANET 801 Pulse/pause Timer-unit VDH doc. 060344 Version: v1.0 Date: 02-02-2006 Software: ALFA 801 Flash File: Do060344.wpd Range: 0-999 * Operation. The ALFA(NET) 801 is a panel mounting timer-unit, with a pulse/pause relay function. The pulse and pause time are set by parameters (P01 and P02).
  • Page 2 SET key and the UP or DOWN key the parameter value can be changed. If no key is pushed for 20 seconds, the ALFA(NET) 801 will return to it’s normal operation and the changes are saved. * Parameters ALFA 801. Para- Description Parameter...
  • Page 3: Error Messages

    In the display of the ALFA(NET) 801 the following error messages can appear: - Setting are lost. Solution: Reprogram the settings. * Technical details. Type : ALFA 801 Pulse/Pause Timer-unit or ALFANET 801 Pulse/Pause Timer-unit with network Range : 0-999 min/sec pulse time 0-999 min/sec pause time...
  • Page 4 * Connections. * Alfanet network connections.

This manual is also suitable for: