Pro-Source AW12H Installation And Operation Instructions

Air-over-water tanks

Advertisement

Available languages

Available languages

Quick Links

Rules For Safe Installation
and Operation
To prevent possible
serious or fatal injury and/or damage
to equipment, system pressure must
be less than 75 pounds per square
inch (PSI) under any circumstances.
Failure to follow this instruction can
result in tank blowup. Install relief
valve in system between pump and
tank capable of passing entire pump
output at 75 PSI.
Do not allow pump,
tank or piping system to freeze.
Freezing can severely damage
equipment and may lead to tank
explosion and serious injury.
Allowing tank to freeze voids warranty.
1. Follow local codes when installing
tank.
2. Test well water for purity before
using it.
3. Disconnect power to pump and re-
lease all pressure in system before
installing or servicing tank.
4. Drain all water from system before
performing any maintenance on
tank.
Installation
1. Use teflon tape on threaded pipe
joints to tank. DO NOT use pipe joint
compound on plastics, as it may
damage the plastic.
2. Install air volume control according
to instructions supplied with air vol-
ume control.
3. Connect inlet and outlet pipes as
shown in illustration.
4. When installing tank in a system
having a submersible well pump, be
sure that orifices are installed and
operating correctly. See Submer-
sible pump owner's manual for more
information.
Pro-Source, Delavan, Wisconsin 53115 USA • Ph. (262) 728-5551
Installation and Operation Instructions
Models AW12H, AW30H, AW42, AW42T, AW85, AW120
Typical Jet Pump Installation
Compression
To
Fitting
Service
Typical Jet Installation with Horizontal Tank
Pressure
Gauge
Pressure
Switch
To
Service
Typical Submersible Installation
Control Box
(3 Wire Models Only)
Union
From Well
Relief
Valve
Gate Valve
Air-Over-Water Tanks
Pressure
Gauge
AVC
Relief
Valve
Plastic
Tubing
Compression Fitting
Regulator
Screw
Relief
Valve
Pump
Plastic
Tubing
Compression
Fitting
Compression Fitting
Pressure
Gauge
Electrical
Disconnect
Air Volume
Control
(U238-14)
Pressure Switch
Pump
AVC
To House
Service
146 0893 SR
S515 (Rev. 3/30/05)

Advertisement

loading

Summary of Contents for Pro-Source AW12H

  • Page 1 To House Union operating correctly. See Submer- Service sible pump owner's manual for more information. From Well Relief Valve Pressure Switch Gate Valve 146 0893 SR Pro-Source, Delavan, Wisconsin 53115 USA • Ph. (262) 728-5551 S515 (Rev. 3/30/05)
  • Page 2 Réservoirs avec air au-dessus de l'eau Instructions d'installation et de fonctionnement Modèles AW12H, AW30H, AW42, AW42T, AW85, AW120 Consignes de sécurité pour Installation typique d'une pompe à éjecteur l'installation et le fonction- nement de l'équipement Manomètre Pour éviter les bles- Contrôleur...
  • Page 3 Tanques de aire sobre agua Instrucciones de instalación y operación Modelos AW12H, AW30H, AW42, AW42T, AW85, AW120 Reglas para una instalación Instalación típica de una bomba de chorro y una operación seguras Manómetro ADVERTENCIA Para evitar posibles lesiones graves o fatales...
  • Page 4: Limited Warranty

    LIMITED WARRANTY Pro-Source, warrants to the original consumer of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period from the date of original installation or manufacture as noted. Product Warranty Period Water Systems Products –...

This manual is also suitable for:

Aw42Aw42tAw30hAw85Aw120