VDH ALFA 802 User Manual

Off-delay timer-unit

Advertisement

Quick Links

VDH doc. 060350
Software: ALFA 802 Flash
* Operation.
The ALFA(NET) 802 is a panel mounting timer-unit, with a off-delay relay function. The off-delay time
is set by the keys on the front panel. The timer-unit has a range from 0-999 minutes, seconds or hours
(P01). The timer-unit has also a contact-input for starting, stopping or waiting the unit (P02).
The ALFANET 802 is provided with a RS 485 network connection, to readout or set the unit on the
PC with ALFANET software. by using a ALFANET PC-Interface.
* Installation.
On the topside of the ALFA(NET) 802 can be read how to connect this unit, such as powersupply,
relay-output, contact input and network.
After power up the ALFA(NET) 802 and the self test is finished the unit displays the off-delay time.
As the output relay is activated the LED 'on' in the display lits to indicate this.
* Control.
The ALFA(NET) 802 Timer-unit can by controlled by three pushbuttons on the front. These keys are:
[] SET
- view / change setting.
[] UP
- increase setting.
[] DOWN - decrease setting.
* Changing current off-delay time.
Push the SET key, the LED 'set' starts blinking. Release the SET key. Now push the SET key again
and together with the UP or DOWN keys the current off-delay time can by changed. A few seconds
after releasing the keys the timer-unit returns to it's normal operation, the LED 'set' switches off.
* Start, Stop and Wait function of the off-delay timer.
Push the UP key to start the timer, the LED 'on' lits and the relay will be activated. During the off-delay
time the timer unit can be set in a waiting mode by pressing the DOWN key. During this waiting mode
the relay will deactivate as P03=0 or stays active as P03=1. During the waiting mode the LED 'on' is
blinking and the remaining time is on hold. To continue the off-delay timer, push the UP key again.
As in the other hand the DOWN key is pressed again (second time), than the off-delay timer is
stopped, the display shows for 5 seconds '000' and the LED 'on' goes off. The timer stops completely
and after 5 seconds the display shows the set off-delay time again in the display. So the unit is ready
for the next start.
User manual
ALFA 802 and ALFANET 802
Off-delay Timer-unit
Version: v1.1
File: Do060350.wpd
1
Date: 26-05-2008
Range: 0-999

Advertisement

loading

Summary of Contents for VDH ALFA 802

  • Page 1 User manual ALFA 802 and ALFANET 802 Off-delay Timer-unit VDH doc. 060350 Version: v1.1 Date: 26-05-2008 Software: ALFA 802 Flash File: Do060350.wpd Range: 0-999 * Operation. The ALFA(NET) 802 is a panel mounting timer-unit, with a off-delay relay function. The off-delay time is set by the keys on the front panel.
  • Page 2 SET key and the UP or DOWN key the parameter value can be changed. If no key is pushed for 20 seconds, the ALFA(NET) 802 will return to it’s normal operation and the changes are saved. * Parameters ALFA 802. Para- Description Parameter...
  • Page 3: Error Messages

    In the display of the ALFA(NET) 802 the following error messages can appear: - Setting are lost. Solution: Reprogram the settings. * Technical details. Type :ALFA 802 Off-delay Timer-unit or ALFANET 802 Off-delay Timer-unit with network Range :0-999 min/sec/hrs Supply...
  • Page 4 * Connections. * Alfanet network connections.