QUBINO ZMNHND1 User Manual

Flush 1d relay

Advertisement

Quick Links

Qubino
The INNOVATIVE and SMALLEST
Flush 1D relay
ORDERING CODE
Z-WAVE FREQUENCY
ZMNHND1
868,4 MHz
ZMNHND2
921,4 MHz
ZMNHND3
908,4 MHz
ZMNHND4
869,0 MHz
ZMNHND5
916,0 MHz
This Z-Wave module is used for switching on or off
the electrical device (e.g. light or fan). The module
can be controlled either through Z-wave network or
through the wall switch.
The module is designed to be mounted inside a
"flush mounting box", hidden behind a traditional
wall switch.
Module supports connection of digital temperature
sensor. It is designed to act as repeater in order to
improve range and stability of Z-wave network.
Supported switches
Module supports mono-stable switches (push
button) and bi-stable switches. The module is
factory set to operate with bi-stable switches.
Installation
Before the installation disconnect power
supply.
Connect the module according to electrical
diagram.
Locate the antenna far from metal elements
(as far as possible).
Do not shorten the antenna.
Danger of electrocution!
Module installation requires a great degree of
skill and may be performed only by a qualified
and licensed electrician.
Even when the module is turned off, voltage
may be present on its terminals. Any work on
configuration changes related to connection
mode or load must be always performed by
disconnected power supply (disable the fuse).
Note!
Do not connect the module to loads exceeding
recommended values. Connect the module only in
accordance to the below diagrams. Improper
connections may be dangerous.
Electrical installation must be protected by over
current protection fuse 10A, Tag lag T, rated
breaking capacity 1500V (ESKA 522.7..) according
to wiring diagram.
Package contents
Flush 1D relay
Electrical diagram 230VAC
Option for different load power supply - DPLS:
Notes for the diagrams:
N
Neutral lead
L
Live lead
Q
Input for electrical device power supply
Q
Output for electrical device
I2
Input for switch /push button or sensor
I1
Input for switch /push button
TS
Terminal for digital temperature sensor
(only
for
Flush
1D
relay
module
compatible digital temperature sensor,
which must be ordered separately).
Electrical diagram 24VDC
Option for different load power supply - DPLS:
Notes for the diagrams:
N
+ VDC
L
- VDC
Q
Input for electrical device power supply
Q
Output for electrical device
I2
Input for switch /push button or sensor
I1
Input for switch /push button
TS
Terminal for digital temperature sensor
(only
for
Flush
1D
relay
module
compatible digital temperature sensor,
which must be ordered separately).
NOTE!
Output contact is voltage free (dry contact), so also
loads
with
different
power supply can
be
connected to the module.
S
Service button (used to
add or remove module
from the Z-Wave
network).
NOTE: Service button S can't be used when
module is connected to 110-230V power supply.
Durability of the module depends on applied load.
For resistive load (light bulbs, etc.) and 10A
current consumption of each individual electrical
device, the durability exceeds 100.000 switches of
each individual electrical device.
Module Inclusion (Adding to Z-wave
network)
Connect module to power supply (with
temperature
sensor
connected
-
if
purchased),
auto-inclusion (works for about 5 seconds
after connected to power supply) or
press service button S for more than 2 second
or
press push button I1 three times within 3s (3
times change switch state within 3 seconds).
NOTE1: For auto-inclusion procedure, first set
main
into inclusion mode and then connect
controller
module to power supply.
NOTE2: When connecting temperature sensor to
module that has already been included, you have
to exclude module first. Switch off power supply,
connect the sensor and re-include the module.
Module Exclusion/Reset (Removing from
Z-Wave network)
Connect module to power supply
bring module within maximum 1 meter (3 feet)
of the main controller,
enable add/remove mode on main controller
press service button S for more than 6 second
or
press push button I1 five times within 3s (5
times change switch state within 3 seconds) in
the first 60 seconds after the module is
connected to the power supply.
By this function all parameters of the module are
set to default values and own ID is deleted
If service button S is pressed more than 2 and less
than 6 seconds (or if push button I1 is pressed
three times within 3s) module is excluded, but
configuration parameters are not set to default
values
.
Associations
Associations enables Flush 1D relay module to
transfer commands inside Z-Wave network directly
(without main controller) to other Z-Wave modules.
Associated Groups:
Root device:
Group
1:
Lifeline
group
(reserved
for
communication with the main controller), 1 node
allowed.
Group 2: basic on/off (triggered at change of the
output state and reflecting its state) up to 16
nodes.
Group 3: basic on/off (triggered at change of the
input I2 state and reflecting its state) up to 16
nodes.
Group 4: Binary Sensor Report (triggered at
change of the input I2 state and reflecting its state)
up to 16 nodes.
Group 5: Notification Report (triggered at change
of the input I2 state and reflecting its state) up to
16 nodes.
Endpoint 1:
Group 1: Lifeline group, 0 nodes allowed.
Group 2: basic on/off (triggered at change of the
output state and reflecting its state) up to 16
nodes.
Endpoint 2:
Group 1: Lifeline group, 0 nodes allowed.
Group 2: basic on/off (triggered at change of the
input I2 state and reflecting its state) up to 16
nodes.
Group 3: Binary Sensor Report (triggered at
change of the input I2 state and reflecting its state)
up to 16 nodes.
Group 4: Notification Report (triggered at change
of the input I2 state and reflecting its state) up to
16 nodes.
Configuration parameters
Parameter no. 1 – Input 1 switch type
Available configuration parameters (data type is 1
Byte DEC):
default value 1
0 - mono-stable switch type (push button)
1 - bi-stable switch type
Parameter no. 2 – Input 2 contact type
Available configuration parameters (data type is 1
Byte DEC):
default value 0
0 - NO (normally open) input type
1 - NC (normally close) input type
Parameter no. 10 - Activate / deactivate
functions ALL ON/ALL OFF
Available configuration parameters (data type is 2
Byte DEC):
default value 255
255 - ALL ON active, ALL OFF active
0 - ALL ON is not active ALL OFF is not active
1 - ALL ON is not active ALL OFF active
2 - ALL ON active ALL OFF is not active
Flush 1D relay module responds to commands
ALL ON / ALL OFF that may be sent by the main
controller or by other controller belonging to the
system.
Parameter no. 11 - Automatic turning off output
after set time
When relay is ON it goes automatically OFF after
time defined by this parameter. Timer is reset to