  • Page 1 USER GUIDE & SERVICE MANUAL Outdoor Collection UONB115 / UONP115 24” Convertible Freezer ● ●...
  • Page 2: Table Of Contents

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Contents Intro Safety Safety and Warning Disposal And Recycling Installation Environmental Requirements Electrical Cutout & Product Dimensions Side by Side Installation Anti-Tip Bracket General Installation...
  • Page 3: U-Line.com

    1. U-Line Customer Care must be contacted immediately at +1.800.779.2547. 2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
  • Page 4: Safety And Warning

    USER GUIDE u-line.com Safety and Warning WARNING NOTICE CALIFORNIA PROPOSITION 65 Please read all instructions before installing, This product contains chemicals known to the operating, or servicing the appliance. state of California to cause cancer and birth defects or other reproductive harm.
  • Page 5: Disposal And Recycling

    USER GUIDE u-line.com Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal,...
  • Page 6: Environmental Requirements

    USER GUIDE u-line.com Environmental Requirements This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models. For best performance, keep the unit out of direct sunlight and away from heat generating equipment.
  • Page 7: Electrical

    USER GUIDE u-line.com Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • Page 8: Cutout & Product Dimensions

    Cutout & Product Dimensions 23 15⁄16” (608 mm) PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or 34 1⁄8” 35 1⁄8”...
  • Page 9: Side By Side Installation

    USER GUIDE u-line.com Side-by-Side Installation 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Two units may be installed side-by-side. Tighten screws fully. Cutout width for a side-by-side installation is the cutout 4.
  • Page 10: Anti-Tip Bracket

    USER GUIDE u-line.com Anti-Tip Bracket 1. Slide unit out so screws on top of unit are easily accessible. 2. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below). 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver.
  • Page 11: General Installation

    USER GUIDE u-line.com General Installation INSTALLATION 1. Plug in the power/electrical cord. LEVELING INFORMATION 1. Use a level to 2. Gently push the unit into position. Be careful not to confirm the unit is entangle the cord or water and drain lines, if level.
  • Page 12: Grille Installation

    USER GUIDE u-line.com Grille Installation REMOVING AND INSTALLING GRILLE WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. Removing the grille 1. Disconnect power to the unit. 2. Loosen the two screws (1).
  • Page 13: Door Swing

    USER GUIDE u-line.com Door Swing Wall 2-1/8" Min. (54 mm) 90° Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless Steel models require 2-1/8" (54 mm) door clearance to accommodate the handle if installed next to a wall.
  • Page 14: Door Adjust

    USER GUIDE u-line.com Door Adjustments 6. Tighten top hinge screws and replace hinge cover. HINGE COVER Hinge cover included with the literature bag is optional. Reversing the Door To install hinge cover: Location of the unit may make it desirable to mount the 1.
  • Page 15 USER GUIDE u-line.com Prepare door for reinstallation: 1. Remove gasket. This will reveal mounting holes for the magnet assembly. 2. Remove magnet assembly from door with T-10 TORX driver. Be sure to only remove the two screws holding the assembly to the door. Reinstall on the opposite end 3.
  • Page 16: Free Standing Kit

    USER GUIDE u-line.com Free Standing Kit The free standing kit is an optional accessory, used when unit is freestanding - not built into a cabinet. To install the kit: 1. Remove grille (see GRILLE INSTALLATION section). 3. Align front hole with hole in shell accessory, hole in base, and hole in grille.
  • Page 17: First Use

    If the temperature displayed is different than selected, the unit is progressing towards the selected temperature. Time to reach set point varies based upon ambient temperature, temperature of product loaded, door openings, etc. U-Line recommends allowing the unit to reach set point before loading.
  • Page 18: Control Operation

    USER GUIDE u-line.com Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and release Unit will immediately turn ON or OFF Press and release to leave interior After 12 hours, factory default is restored; light will Leave interior light on light on for 12 hours;...
  • Page 19: Airflow And Product Loading

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency. Do not block the front grille, internal fans or vents at any time, or the unit will not perform as expected.
  • Page 20: Interior Adjustments

    USER GUIDE u-line.com NOTICE Interior Adjustments Do not remove the track rails from the cabinet. FREEZER BASKETS To reinstall: Freezer Basket Installation & Removal 1. Align the left and right basket channels with the tracks in the cabinet. Ensure an even track engagement on Freezer baskets are removable for cleaning.
  • Page 21: Cleaning

    USER GUIDE u-line.com Cleaning To clean integrated panels, use household cleaner per the cabinet manufacturer’s recommendation. Stainless Models Stainless door panels and handles can discolor when INTERIOR CLEANING exposed to chlorine gas, pool chemicals, saltwater or Disconnect power to the unit.
  • Page 22 USER GUIDE u-line.com NOTICE The drain pan was not designed to capture the water created when manually defrosting. To prevent water from overflowing the drain pan and possibly damaging water sensitive flooring, the unit must be removed from cabinetry. To defrost: 1.
  • Page 23: Cleaning Condenser

    USER GUIDE u-line.com Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary.
  • Page 24: Extended Non-Use

    If the unit will be exposed to temperatures of 40°F (5°C) or less, the steps above must be followed. For questions regarding winterization, please call U-Line at 800.779.2547. CAUTION Damage caused by freezing temperatures is not covered by the warranty.
  • Page 25 One Year Limited Warranty For one year from the date of original purchase, this U-Line product warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase.