IgniteNet MetroLinq ML1-60-35 Quick Start Manual

Outdoor 60ghz ptp + 5ghz + 2.4ghz

Advertisement

Quick Links

Q ui c k Sta r t G u id e
MetroLinq™ Outdoor 60GHz PTP + 5GHz + 2.4GHz
ML1-60-35 | ML1-60-19
Welcome to MetroLinq™
Interference-Free Gigabit Wireless
Unboxing
After opening the box, you will find...
MetroLinq™ (ML1-60-35, or ML1-60-19)
PoE Power Supply
Power Cable
Tools/Items Required
13 mm Socket Wrench
Flat-Head Screwdriver
Ethernet Cables
Options
Standard Bracket ICC-BRACKET-STD
Long Range Precision Bracket ICC-BRACKET-LR
Alignment Scope ICC-SCOPE-9x50
For helpful training and user-case information, please go to
ignitenet.com/support
Assembly
The MetroLinq™ Standard Bracket and Long Range Precision Bracket
(both ordered separately) are designed for wall and pole mounting
(25 mm - 80 mm pole diameter). Choose what is best for your
location and select hardware accordingly.
1
2
4
1
Ensure all four position-locking bolts on the Standard
Bracket are tight before installing.
www.ignitenet.com
3
2
Install the Standard Bracket onto MetroLinq™ using four M8
bolts, lock washers, and flat washers.
3
3
Ensure all four position-locking bolts on the Long-Range
Precision Bracket are tight before installing.
4
Install the Long-Range Precision Bracket onto the
MetroLinq™ using four M8 15 mm bolts, spring-lock
washers, and flat washers.
– 1 –
2
1
4
E052018-CS-R01
150200001975X

Advertisement

loading

Summary of Contents for IgniteNet MetroLinq ML1-60-35

  • Page 1 ◆ Alignment Scope ICC-SCOPE-9x50 Precision Bracket are tight before installing. For helpful training and user-case information, please go to ignitenet.com/support Assembly The MetroLinq™ Standard Bracket and Long Range Precision Bracket (both ordered separately) are designed for wall and pole mounting (25 mm - 80 mm pole diameter).
  • Page 2 Verify that there is a good electrical connection to a grounding point (no paint or isolating surface treatment). IgniteNet strongly recommends using the ICC-SCOPE-9x50 Use the included (M4) screw to attach a grounding wire (not included) to the grounding point on the unit, and then to Alignment Scope for alignment.
  • Page 3 The default IP mode is DHCP client, so if the device obtains an address from a DHCP server on the network, then use that IP (you can use the Discovery Tool from the IgniteNet support site to find the DHCP address). If the device does not obtain a DHCP address, it reverts to the fallback IP of 192.168.1.20 and you can access it on that IP.
  • Page 4: Safety And Regulatory Information

    Europe - EU Declaration of Conformity autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas Hereby, IgniteNet Inc. declares that the radio equipment type: produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout MetroLinq™ Outdoor 60GHz PTP + 5GHz + 2.4GHz, ML1-60-35 and brouillage radioélectrique subi, même si le brouillage est susceptible...
  • Page 5: Warnings And Cautionary Messages

    Quick Start Guide Warnings and Cautionary Messages Hardware Specifications Warning: This product does not contain any serviceable user Chassis parts. Warning: Installation and removal of the unit must be carried Size (L x W x H:) ML1-60-35: out by qualified personnel only. 350 x 350 x 200 mm (13.78 x 13.78 x 7.87 in.) Warning: When connecting this device to a power outlet,...

This manual is also suitable for:

Metrolinq ml1-60-19