INSTALLATION INSTRUCTIONS

Flow Switch
&
Temperature/
Pressure
Gauge
For Atmospheric
Models C-R206AE-406AE
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids or other
combustible materials in the vicinity of this or any other appliance. To do so may result in an explosion or fire.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
NOTE: Not for use with millivolt units.
Catalog No. 6000.59.1B
Effective: 03-08-12
For Low NOx
Models C-R207AE-407AE
Replaces: 03-28-07
P/N 241309 Rev. 3

Advertisement

loading

Summary of Contents for Raypak C-R206AE-406AE

  • Page 1: Installation Instructions

    Gauge For Atmospheric For Low NOx Models C-R206AE-406AE Models C-R207AE-407AE FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance. To do so may result in an explosion or fire.
  • Page 2 Before Starting NOTE: These instructions are intended primarily for use by qualified personnel specifically trained and experienced in the installation of this type of heating 1) Turn off power to the heater at the circuit breaker. equipment and related system components. Installation and service personnel must be licensed 2) Turn off gas supply.
  • Page 3 7. Locate and install the 2” CPVC manifold adapter 12. Locate and install the flow switch cover, if not onto the Outlet side (see Fig.1). Careful not to strip already installed. the threads on the manifold adapter. 13. Locate and install the T&P gauge on the side of 8.
  • Page 4 26. Cycle the heater a few times to verify flow switch operation. FLOW SWITCH WIRES Fig 5: Completed Assembly CONNECTED TO “SPARE” JUMPER Fig 4: “Spare” Jumper Connections www.raypak.com Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 Litho in U.S.A.