Beckett water submersible pump service and maintenance

Advertisement

Available languages

Available languages

Quick Links

These Beckett Submersible Pumps are direct-driven. All electrical parts and connections are completely encapsulated with epoxy (not oil-
filled) and are environmentally safe and energy-efficient. These features, combined with very low energy consumption, make for a safe
and convenient pump that is economical to operate. Beckett pumps will circulate and aerate your pond's water. They will also keep your
pond from becoming stagnant. In addition, it is essentially maintenance-free.
INDOOR AND OUTDOOR USE.
These pumps are for
of the inlet screen can be reduced by placing the pump on a brick or patio stone in the water to raise it above the level of the debris,
which accumulates on the bottom.
1. RISK OF ELECTRICAL SHOCK - Always disconnect from power outlet before handling the pump or putting your
hands into the water.
2. RISK OF ELECTRICAL SHOCK - This pump is supplied with a grounding conductor and a grounding-type
attachment plug (3-prong plug). To reduce the risk of electric shock, be certain that it is connected only to a properly
grounded, grounding-type receptacle. Do not remove the grounding pin.
3. RISK OF SEVERE ELECTRICAL SHOCK - Connect only to a grounded receptacle protected by a ground-fault
circuit-interrupter (GFCI). A GFCI must be provided in accordance with Section 680-51 of the National Electric Code.
Contact a qualified electrician if you cannot verify that the receptacle is protected by the GFCI.
4. TO REDUCE THE RISK OF ELECTRICAL SHOCK –
Never use an extension cord to connect unit to electrical supply; provide a properly located GFCI outlet.
A.
Never bury the 3-prong plug of the cord, it is not waterproof and severe electric shock will occur.
B.
IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING:
Check the circuit breaker and try another outlet to ensure the pump is getting electrical power.
Check the pump discharge and tubing for kinks and obstructions. Algae build up can be flushed out with a garden hose.
Check the inlet screen to ensure it is not clogged with debris.
Remove the inlet screen and volute to access the impeller area. Turn the impeller to ensure it is not broken or jammed.
If the impeller area is encrusted with minerals or corrosion, gently scrape the area clean, being careful not to damage the shaft
seal, and apply a drop of light oil to the shaft.
Never attempt to disassemble the impeller assembly. If it becomes worn or broken, simply replace the entire assembly.
If the pump is taken out of service for a period of time (such as during winter), flush the pump out with clean fresh water and drain
thoroughly before storing.
Monthly maintenance will add to your pump's life.
Ensure that the cord is protected from wear and abrasion.
Never attempt to replace or shorten the cord
CAUTION:
If the pump is allowed to run dry, it will sustain permanent heat damage after 30 minutes. Your Beckett
pump is intended to pump fresh water only. Do not use to pump oils, solvents, fuels, or salt water. Do not allow to freeze.
BECKETT SUBMERSIBLE PUMPS
MODELS: G210, G325 & G535
SERVICE AND MAINTENANCE
!
These Pumps are designed to operate completely submerged. Cleaning
WARNING
CY8143
Rev. D

Advertisement

loading

Summary of Contents for Beckett G325

  • Page 1 If the pump is allowed to run dry, it will sustain permanent heat damage after 30 minutes. Your Beckett pump is intended to pump fresh water only. Do not use to pump oils, solvents, fuels, or salt water. Do not allow to freeze. MODELS: G210, G325 & G535 These Pumps are designed to operate completely submerged. Cleaning...
  • Page 2: For Your Records

    Each Beckett Corporation (“Beckett”) product is warranted to be free from defects in material and workmanship for the applicable Warranty Period (herein so called) set forth below. The Warranty Period for each product commences on the date of purchase by the original purchaser. The Warranty Periods are as follows: Product Type or Name Warranty Period Pump Models:...
  • Page 3 BOMBA SUMERGIBLE BECKETT MODELOS: G210, G325 y G535 Las Bombas sumergibles de Beckett son manejadas totalmente con epoxy (no llenadas con aceite), y son ambientalmente seguras y economizan energía. Éstas características, combinadas con el consumo de energía muy bajo, hacen que ésta bomba sea segura, conveniente y de funcionamiento económico. Las Bombas de Beckett circularán y airearán el agua de su estanque para que el agua no quede estancada.
  • Page 4 Cada uno de los producto de Beckett Corporation (“Beckett”) esta garantizado por el Periodo de Garantía (como se define en esta garantía) que se menciona abajo, contra defectos en material y manufactura. El Periodo de Garantía para cada producto comienza en el día de compra por el comprador original. El Periodo de Garantía es el siguiente: Tipo de Producto o Nombre Modelos de Bombas: Serie G;...
  • Page 5 SUBMERSIBLES DE POMPE DE BECKETT MODÈLES : G210, G325 et G535 Ces pompes submersibles Beckett sont à entraînement direct. Toutes les pièces et connexions électriques sont entièrement encapsulées dans de l’époxyde (non pas remplies d’huile) en plus d’être écologiques et à bon rendement énergétique. Ces fonctions, combinées à...
  • Page 6: Garantie Limitée

    Chaque produit de Beckett Corporation (Beckett) est garanti contre les défauts de matières et de fabrication pour la période de garantie applicable (ainsi appelée dans les présentes) indiquée ci-dessous. Pour chaque produit, la période de garantie commence à la date de l’achat par l’acheteur initial. Les périodes de garantie sont les suivantes : Produit Période de garantie Modèles de pompes :...

This manual is also suitable for:

G535Pond pump g210