Aalborg OSV1-6-P Operating Manual

Optical sensor switch for p style meters; s style meters; t style meter

Advertisement

Quick Links

Technical Data Sheet No. TD-OSS-052018
Date of Issue: May 2018

OPERATING MANUAL

Optical Sensor Switch
PICTURE SHOWING
OPTICAL SENSOR SWITCHES
INSTALLED ON A
TYPICAL ROTAMETER
aalborg
®
20 CORPORATE DRIVEORANGEBURG, NY 10962PHONE: 845.770.3000FAX: 845.770.3010
e-mail: info@aalborg.comtoll free in usa or canada: 1.800.866.3837web site: www.aalborg.com

Advertisement

Table of Contents
loading

Summary of Contents for Aalborg OSV1-6-P

  • Page 1: Operating Manual

    Technical Data Sheet No. TD-OSS-052018 Date of Issue: May 2018 OPERATING MANUAL Optical Sensor Switch PICTURE SHOWING OPTICAL SENSOR SWITCHES INSTALLED ON A TYPICAL ROTAMETER aalborg ® 20 CORPORATE DRIVEORANGEBURG, NY 10962PHONE: 845.770.3000FAX: 845.770.3010 e-mail: info@aalborg.comtoll free in usa or canada: 1.800.866.3837web site: www.aalborg.com...
  • Page 2 CAUTION: This product is not intended to be used in life support applications! NOTE: Aalborg® reserves the right to change designs and dimensions at its sole Discretion at any time without notice. For certifi ed dimensions please contact Aalborg®.
  • Page 3: General Description

    NOTE: To order a fl ow meter with a single Optical Sensor Switch add “O1-” to P, S, or T Model Numbers. Example: O1-P11A4-BA0-032-41-ST-VN. ORDERING INFORMATION FOR OPTICAL SENSOR SWITCH ACCESSORY PART NUMBER DESCRIPTION OSV1-6-P Optical Sensor Switch for 65mm P Style Meters OSV1-1-P Optical Sensor Switch for 150mm P Style Meters OSV1-6-S...
  • Page 4: Troubleshooting

    OPTICAL SENSOR SWITCH CONNECTION WIRE LEAD COLOR CONNECTION BLACK Positive Power Lead (+10 to 30 VDC) YELLOW Negative Power Lead GREEN NPN output #1 NPN output #2 (Complementary to Output #1) The sensor consists of two parts: transmitter and receiver. When power is properly connected the power supply indicator (green LED) on the transmitter is constantly on.
  • Page 5 PR-F Stable operation Output indicator (green) indicator (orange) Power supply indicator (green) ø3.2 mm Receiver 8 mm Transmitter Output Wiring Diagram Brown/(1) 10 to 30 VDC Black/(4) Load Output 1 White/(2) Load Output 2 Blue/(3)
  • Page 6: Warranty

    Shipping charges are borne by the customer. This warranty is void if the equipment is damaged by accident or misuse, or has been repaired or modifi ed by anyone other than Aalborg ® or factory authorized service facility. This warranty defi nes the obligation ®...
  • Page 7 ANALYT_MTC@T-online.de e-mail: info@analyt-mtc.de AALBORG ® a registered trademark of Aalborg Instruments and Controls, Inc. Aalborg reserves the right to make changes to information and specifi cations in this manual without notice. © Copyright 2001 Aalborg Instruments. All rights reserved.
  • Page 8: Peristaltic Pumps

    Products Manufactured By Aalborg ROTAMETERS Single Tube Aluminum / Brass / Stainless  Interchangeable Glass Flow Tubes  Optional Valves Multiple Tube Two to Six Channels  Aluminum or Stainless PTFE Single and Multiple Tube   Chemically Inert 1 to 4 Channels...