Dual Bank Control Battery Switch
772-DBC
400A Dual Bank Control (Retail Packed)
772-DBC-B
(Bulk Packed)
This innovative (patent pending) switch combines the functionality of three battery switches (House,
Start & Emergency Parallel) into one by simultaneously controlling two battery banks and two loads.
In the unlikely case of engine malfunction, a unique safety position isolates one load (e.g. House
ON/Start OFF) so emergency radios call can be made. With improved access for cabling and three
mounting options, the 772-DBC battery switch offers signifi cant savings in space and installation time.
Features & Benefi ts:
• Industry standard footprint
• Three mounting options – surface, rear-panel and front-panel
• Compatible with metric and imperial mounting fasteners
• User friendly design
• Improved access for cables
• Removable knob for isolation/safety
• Includes back cover and three side panels for security and cable protection
• Designed to withstand harsh marine environments
• High temperature reinforced plastics
Specifi cations:
• Continuous rating: 400A*
• Intermittent rating: 600A* (5min)
• Cranking rating: 1500A* (10sec)
• 12-48V DC (Higher voltage applications on request)
• Connection stud size: M10 (3/8")
• IP66 – protection from powerful water jets
• Ignition protected
• Independently tested to meet UL1107 standards
• CE marked
*Electrical ratings achieved using cable size 120mm²
Mounting Template
Installation Instructions: IMPORTANT! Read before installing
• It is recommended that electrical terminations and connections are
carried out by a marine electrical technician.
• Negative terminations, and Positive terminations must be to the same
numbered studs i.e. both Negatives must be connected to studs num-
bered "1", or both Negatives connected to studs numbered "2". Failure
to do this will result in short circuit or fi re!
• These battery switches are for isolation purposes and are not designed
for switching under load. Ensure there are no circuits with high
ure:
inductive loads directly connected to the switch in order to prevent any
ve clipping
recess panel
panel mounting
Surface Mount Screw Holes
91.9 [3.62]
38.0 [1.50]
53.9 [2.12]
30.4 [1.20]
47.7 [1.88]
13.9 [0.55]
55.0 [2.17]
www.bepmarine.com
For Backplate
Loads
Loads
Positive
Bus
House
Battery
Fuse
-
+
House
Battery
5
Use 3
"
8
holesaw
sudden in-rush of current which may cause damage to the switch.
• Although specially selected chemical resistant materials have been
used, it is recommended that for maximum product life only plastic
safe corrosion inhibiting sprays are used.
• Ensure all cables are sized correctly for the loads they carry - refer to
www.bepmarine.com to calculate correct cable sizes.
• Ensure all electrical connections are correctly tightened to prevent any
damage to the battery switch.
|
www.mastervolt.com
Isolated Safety
Position: "1
Dual Bank Control Switch
1
+
1
Battery
Loads
Engine
1
2
DVSR (710-140A)
DVSR
provides automatic
battery charging
of second bank
Optional
Start
Batt
Fuse
-
+
Negative
Start
Bus
Battery
|
www.marinco.com
5 YEAR WARRANTY
Loads
Engine
2
+
2
Battery
Example System:
NOTE -This
diagram is a
guide only showing
Dual Bank Control
Switch onnections
and is not intended
as a full electrical
systems wiring
diagram.