1. PARTS
A.
Foamer Assembly
B.
Plastic chemical supply tubing w/ foot valve and ceramic weight
C.
Metering tip kit
D.
Outlet hose 25' long (optional accessory)
E.
Shut-off valve (optional accessory)
2. MOUNTING
Hold the unit in position on the wall and locate the positions for the mounting screws. Drill holes in wall
approximately 1" deep and insert mounting anchors. Install top 2 mounting screws, leaving approximately
1/8" extension between the wall and screw head. Mount the Foamer unit by inserting the screw heads through
the keyhole slots in the cover and tighten the screws. Screw the bottom 2 screws into the wall to secure.
Note: Attach proper air supply fittings before mounting unit to wall. See caution warning in Section 3
for air inlet.
3. INSTALLATION
This product is designed only to be used as described in this instruction sheet. Adhere to all warnings and
cautions identified in this document.
A.
Water inlet is 3/4" garden hose swivel.
B.
Air inlet is 1/4" NPT. CAUTION: When tightening air supply fittings into the ball valve, be sure to
secure the ball valve with a wrench or other similar tool. Avoid rotating ball valve when tightening
air supply fittings.
C.
Foam outlet is 3/4" garden hose. Attach shut-off valve to the end of the hose. See Table 1 for hose
limitations.
D.
Detergent can be drawn directly from any chemical container, which may be set on the floor. The unit
should be mounted no more than 6' above the chemical container; greater lifts reduce injection capacity.
Form I-739
Rev. F-40211
STATION FOAMER
INSTALLATION INSTRUCTION
WARNING: Installations must conform to all local and national plumbing codes and use
approved backflow prevention and pressure relief devices where required.
ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER
IS NOT IN USE.
Always read SDS for all chemicals used and follow personal protective guidelines.
Page 1 of 7

Advertisement

loading

Summary of Contents for DEMA 294DC

  • Page 1 MODEL 294DC FOAMER & 294DC-DS DROP ® STATION FOAMER INSTALLATION INSTRUCTION NOTE: 294DC-DS is intended for use with another mixing device and to be used as a foaming drop station. 1. PARTS Foamer Assembly Plastic chemical supply tubing w/ foot valve and ceramic weight Metering tip kit Outlet hose 25’...
  • Page 2: Operation

    DEMA MODEL 294DC FOAMER & 294DC-DS DROP ® STATION FOAMER INSTALLATION INSTRUCTION 4. CHEMICAL ADJUSTMENT Caution: Use care when handling hazardous chemicals. Chemical dilution rates are set with a tip screwed into the inlet barb on the metering block. Select the proper tip using Table 3 as a guide.
  • Page 3 DEMA MODEL 294DC FOAMER & 294DC-DS ® DROP STATION FOAMER INSTALLATION INSTRUCTION TABLE 3 Induction Rates for Viscosities Shown Metering Tip 1 cps 75 cps 200 cps 500 cps Color Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio Clear 0.84 152-1 0.65...
  • Page 4 DEMA MODEL 294DC FOAMER & 294DC-DS ® DROP STATION FOAMER INSTALLATION INSTRUCTION POSSIBLE SITUATIONS SITUATION CAUSE SOLUTION Chemical tube not immersed in chemical Immerse tube in chemical or replace. or chemical depleted. Air pressure is too high for water. Adjust air regulator down.
  • Page 5 DEMA MODEL 294DC FOAMER & 294DC-DS ® DROP STATION FOAMER INSTALLATION INSTRUCTION 294DC Assembly OPTIONAL ACCESSORIES PART NO. DESCRIPTION PART NO. DESCRIPTION 16-11 Ball Valve (1/4” NPT) 65-2 Ball Valve (3/8” NPT) 25-137-9U Close Nipple (1/4” NPT) 93-104-1 Swivel Adapter Stem...
  • Page 6 DEMA MODEL 294DC FOAMER & 294DC-DS ® DROP STATION FOAMER INSTALLATION INSTRUCTION 294DC-DS Assembly PART NO. DESCRIPTION PART NO. DESCRIPTION 16-11 Ball Valve (1/4” NPT) 65-2 Ball Valve (3/8” NPT) 25-137-9U Close Nipple (1/4” NPT) 93-104-1 Swivel Adapter Stem 93-1...
  • Page 7 “O”- rings, diaphragms, squeeze tubing and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty will be void.

This manual is also suitable for:

294dc-ds