129-145 REMOTE MOUNTING KIT
The 129-145-1, -2 and -3 mounting kits provide an easy, efficient method to panel mount the ED510
display module. Each kit contains a mounting plate, gasket, two (2) 8-32 x 1 1/4" mounting screws,
and connection cable: ED580-4 (4 foot cable) with the 129-145-1, ED580-8 (8 foot cable) with the
129-145-2, and ED580-2 (2 foot cable) with the 129-145-3.
ED610 MULTI-PORT CABLE CONNECTOR WITH TERMINAL STRIP
The ED610 is a multi-port adapter with two RJ45 and one RJ12 (4P4C) telephone jack connectors
and a 10-connector terminal strip. It facilitates remote cable connections between the E110 control,
ED510 Display Module, and the E500 Communication Interface. The ED610 is mounted on a flat
surface with two screws and is recommended where cable runs greater than eight (8) feet are required.
ED580 REMOTE DISPLAY CABLES
The ED580 remote display cable is a cable in varying lengths (2', 4', and 8') with an RJ45 connector
on each end of the cable. The ED580 is used to mount the ED510 display module remote from the
Flame-Monitor control (with EP programmers, Engineering code 28 or later or EPD programmers,
Engineering code 02 or later).
ED512 REMOTE MOUNTING CABLES
The ED512 remote mount cable is a cable in varying lengths (2', 4', and 8') with an RJ12 (4P4C) con-
nector on each end of the cable. The ED512 is used with the ED610 multi-port connector for connect-
ing the Flame-Monitor control (with EP programmers, Engineering code 28 or later or EPD
programmers) to the E500 Communication Interface. The ED512 cables are also used to customize
E300 messages. Refer to bulletins E-3001 and EC-3451.
ED150 REMOTE RESET CABLES
The Remote Reset Cables are 10 conductor flat ribbon cables with a connector on one end and with
two stripped and tinned conductors on the opposite end. Maximum length available is 25 feet
(7.62m). A momentary contact switch connected to the stripped end of the cable will allow for remote
reset of the FLAME-MONITOR.
See CAUTION on Page 3.
FLAME-MONITOR™
SYSTEM ACCESSORIES
129-145 Remote Display Mounting Kit
ED610 Multi-port Cable Connector
ED580 Remote Display Cables
ED512 Remote Mounting Cables
ED150 Remote Reset Cables
®
E-8002
MARCH 27, 2015
and Terminal Strip
1

Advertisement

loading

Summary of Contents for Fireye 129-145-1

  • Page 1 ED150 Remote Reset Cables 129-145 REMOTE MOUNTING KIT The 129-145-1, -2 and -3 mounting kits provide an easy, efficient method to panel mount the ED510 display module. Each kit contains a mounting plate, gasket, two (2) 8-32 x 1 1/4" mounting screws, and connection cable: ED580-4 (4 foot cable) with the 129-145-1, ED580-8 (8 foot cable) with the 129-145-2, and ED580-2 (2 foot cable) with the 129-145-3.
  • Page 2: Ordering Information

    Insert the mounting screws into the threaded inserts and tighten. Insert the 2 foot cable (129-145-3), 4 foot cable (129-145-1) or 8 foot cable (129-145-2) into the RJ45 style connectors on both the ED510 display and the EP Programmer Module (Engineering code 28 or later).
  • Page 3 Fireye does not recommend remote reset locations beyond sight and sound of the burner.
  • Page 4  FIGURE 2. Wiring Connections for ED610 and ED510 Remote Display NOTE: To disable the reset function on the remote display, move the jumper ED580-2, -4, -8 on EITHER ED610 multi-port connec- ED580-2, -4, -8 ED580-2, -4, -8 tor from position 1-2 to position 2-3. ED610 ED610 FLAME ON...
  • Page 5: Flame-Monitor

    ® FIGURE 3. Wiring for E500 Communication Interface TO RJ12 (4P4C) CONNECTOR TO RJ12 (4P4C) CONNECTOR ON EP/EPD PROGRAMMER EP/EPD PROGRAMMER E110 E110 FERRITE FLAME-MONITOR FERRITE FLAME-MONITOR CORE CORE E500 COMMUNICATION INTERFACE ED512-2, -4, -8 ED512-2, -4, -8 ED610 ED610 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 BLACK...
  • Page 6  FIGURE 4. Wiring for Modbus Protocol TO RJ12 (4P4C) CONNECTOR TO RJ12 (4P4C) CONNECTOR ON EP/EPD PROGRAMMER ON EP/EPD PROGRAMMER E110 E110 FERRITE FLAME-MONITOR FERRITE FLAME-MONITOR CORE CORE OPTION 1 TO PC, PLC, ETC. EC485 ED512-2, -4, -8 ED512-2, -4, -8 RS485 TO RS232 ED610...
  • Page 7 (e.g. daisy-chain) wiring configuration. The Fireye communication software program (P/N E720) running on an IBM compatible PC is required for communication with the E340 controls. Fireye recommends using the E500 Communication interface when communicating with the E340 controls, since the E500 provides communication with the Flame-Monitor™ flame safeguard con- trols as well.
  • Page 8 Fireye warranty, as stated in its General Terms and Conditions of Sale, pertains only to the Fireye products and not to any other equipment or to the combined system or its overall performance.

This manual is also suitable for:

129-145-2129-145-3Ed610Ed512-2Ed512-4Ed512-8 ... Show all