Page 1
® N E W W O R L D P O W E R INSTRUCTION INSTRUCTION MANUAL MANUAL DC SERIES DC SERIES FIVE STAGE SMART CHARGER FIVE STAGE SMART CHARGER 30A - 12V 30A - 12V 15A - 24V 15A - 24V...
Page 2
Please remember to complete and return your registration card on the last page of this manual to validate your 2-year warranty. Please retain your receipt as proof of purchase. LATRONICS PO BOX 73 MOFFAT BEACH Q 4551 PH: 61 7 5491 6988 FAX: 61 7 5491 6792 technical@latronics.com EMAIL: WEB: www.latronics.com...
Latronics for a breach of condition or warranty that cannot be exposed to the open environment, and free from contaminates (i.e. excluded is limited (at Latronics option) to the replacement or repair of the goods Exhaust gases, sea air, battery gases, dust).
BATTERIES FAULT FINDING BATTERY SIZING Should the charger appear to be malfunctioning we suggest the following to eliminate any external problems. To ensure optimum performance, it is important to match the charger size according to the capacity of your batteries. Use this formula as a general Turn the charger OFF by disconnecting the AC plug and switching guide: the circuit breaker OFF to disconnect from the batteries.
12-Volt System radio and in unusual cases may interfere with TV reception. Over the years Latronics has continued to invest significant time and effort in the reduction of RFI related emissions from the entire product range, so that they comply with the appropriate International and/or Australian Standards.
In order to access these options you have to open the Charger. Before altering the settings switch Charger OFF, adjust the setting and switch All Latronics Chargers have an isolation rating of 3500V between AC Charger back ON again. We recommend these adjustments be carried and DC via the toroidal transformer, which ensures extremely safe and out by qualified personnel or your system installer.
CHARGER OPERATION When the charger is first switched on all LED’s light up for one second while the microprocessor performs a start up and system check procedure. INDICATOR LED is OFF when no AC power is present. LED is ON when AC power is present. LED will flash when charger enters silent mode cycle.