Key No.
Part No.
Product Description
1
03018009
Pin for handle
2
01013036
Handle for 1.5" 4-way Valve
3
03011003
Ø4*12 Self-drilling screw
4
01013040
Pressing Ring
5
01013041
Fixation for 1.5" 4-way Valve Handle
6
01181003
Washer for 1.5" 4-way Valve Handle
7
02011017
O-Ring for Rotor
8
89280104
Sight Glass with O-Ring
9
01111048
Connector for Pressure Gauge/Stopper
10
06021013
Plastic pressure gauge With O-Ring(40Psi)
11
02311005
Spider Gasket
01013098
Lid for for 1.5" 4-way Valve Rotor
12
01021003
Rotor for 1.5" 4-way Valve
13
01013039
1.5" 4-way Valve Rotor Connector
14
02011021
O-Ring
for Rotor Connector
15
02011018
O-Ring
Base for 1.5" 4-way Valve (Clamp)
16
01013038
O-Ring for 1.5" 4-way Valve (Thread)
02011027
17
02011028
O-Ring for 1.5" 4-way Valve (Clamp)
18
89281301
1.5" 4-way Valve Body
19
02020013
O-Ring for 1.5" Connector
1.5" Connector (black)
20
01013015
21
02011003
O-Ring for 1.5" Union
1.5" Union (A/E)
22
01171153
1.5" Union Nut (black)
23
01013017
Valve Position
Function
Normal Filtration and Vacuuming
FILTER
BACKWASH
Cleaning Filter by reversing the flow
RINSE
Used after backwash to flush dirt from valve
Shuts off all flow to filter or pool
CLOSED
!
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING
SYSTEM (e.g., CLAMP, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE
SYSTEM AND BECOME PRESSURIZED . PRESSURIZED AIR CAN CAUSE THE LID OR VALVE TO
BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE
TURN PUMP OFF BEFORE CHANGING VALVE POSITION.
!
TO PREVENT DAMAGE TO THE PUMP AND FOR PROPER OPERATION OF THE SYSTEM,
!
CLEAN PUMP STRAINER AND SKIMMER BASKETS REGULARLY.
!
DO NOT UNSCREW SCREWS OF FLANGE CLAMP WHILE PUMP IS RUNNING.
Qty
1
1
5
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
3
2
3
WARNING
4
FSP350-4W / FSP400-4W / FSP450-4W / FSP500-4W / FSP650-4W
INSTALLATION
* Install filtration system including pump,filter tank and multiport valve.
* The filter system should be installed as close as possibie to the swimming pool and preferably at a level
of 0.50 metres below the surface of the water in the swimming pool. Make sure there is drainage available
at the place where the filter is to be installed.
* PUMP
1) Only qualified,licensed personnel should install pump and wiring.
2) Electrical Contractors Please Note:All 220 volt 50Hz pump must be wired to the main power supply
trough an approved and correctly rated contractor.
3 Allow for gate valve in suction piping.
)
4 Pump suction and discharge connections have moulded in
)
beyond these stops.
* FILTER TANK and MULTIPORT VALVE
1 Loading the sand media.Filter sand media is loaded through the top opening of the filter.
)
a Loosen the plastic clamps from tank neck.
)
b Cap internal pipe with plastic cap to prevent sand from entering it.
)
c We recommend filling tank approximately 1/2 way with water to provide a cushion effect when the filter
)
sand is poured in. This helps protect the under-drain laterals from excessive shock.
d Carefully pour in correct amount and grade of filter sand.Be sure center pipe remains centered in
)
Sand surface should be leveled and should come to about the middle of the filter tank.Remove
plastic cap from internal pipe.
2 Assemble filter control valve to filter tank.
)
a Insert filter control valve(with O'ring in place)into the tank neck,taking care that the center pipe
)
slips into the hole in the bottom of the valve.
b Place two plastic clamps around valve flange and tank neck and tighten just enough so that the
)
valve may Be rotated on tank for final positioning.
c Carefully screw pressure gauge(with O'ring in place)into tapped hole in valve body.Do not over-tighten.
)
d Connect pump to control valve opening marked PUMP with hose.After connections are made,tighten
)
clamps with screwdrive,tapping around clamp with screwdrive handle to help seat valve flange clamp.
3 Make return to pool pipe connection to control valve opening marked RETURN and complete other
)
necessary plumbing connections,suction lines to pump,waste,etc.
4 To prevent water leakage,be sure all pipe connections are tight.
)
FILTER & PUMP COMBO
Installation & Operating Instruction
thread stops,do not try to screw pipe in
1
opening.
EMFS16030901

Advertisement

loading

Summary of Contents for emaux FSP350-4W

  • Page 1 1.5" VALVE REPLACEMENT PARTS FSP350-4W / FSP400-4W / FSP450-4W / FSP500-4W / FSP650-4W Key No. Part No. Product Description 03018009 Pin for handle 01013036 Handle for 1.5" 4-way Valve FILTER & PUMP COMBO 03011003 Ø4*12 Self-drilling screw 01013040 Pressing Ring Installation &...
  • Page 2 Diffuser 89022306 Motor SD/SQ/SS/ST033(110V/60HZ) 02011026 Sleeve for Hose 01311014 Impeller SS120(220V/50HZ) 89022301 Motor SD/SQ/SS/ST050(110V/60HZ) 89030301 FSP350-4W Plastic Hose with Nut 89030401 FSP400-4W Plastic hose with Nut 01311015 Impeller SD020/SD50/SQ20/SQ50/SS20/SS50/ST20/ST50 89022302 Motor SD/SQ/SS/ST075(110V/60HZ) 89030501 FSP450-4W Plastic hose with Nut 01311016 Impeller SD33/SD75/SQ33/SQ75/SS33/SS75/ST33/ST75...

This manual is also suitable for:

Fsp500-4wFsp450-4wFsp650-4wFsp400-4w