Download Print this page

EL EL4855 Installation Instructions

Wireless 2-way pir / pet camera detector

Advertisement

Quick Links

 
Wireless 2-Way PIR / PET
Camera Detector
Models: EL4855/EL4855P  
EN
 
Installation Instructions
Description
The EL4855/EL4855PI is a battery powered 2‐Way 
wireless PIR/PET detector that includes an integrated 
camera for visual verification and is compatible with all 
Electronics Line 2‐Way security systems. 
Features include:
14m coverage (wide angle) with 90° field‐of‐view 
Installation height 2.4m 
VGA or QVGA camera resolution 
Discreet IR flash allows imaging in complete 
darkness, up to 10m (33') 
Sequence of images upon event, configurable 
number and fps 
During disarm, events are ignored to save battery 
and for privacy 
On‐demand images initiated from authorized 
Smartphone or web browser 
Two RF channels with separate antennas: One for 
control, second channel for image transmission 
Images stored on detector until transmission to panel 
complete 
2 long‐life lithium batteries for extended battery life 
Frequency: 868Mhz or 433Mhz 
PET Immunity option (45Kg animals) 
Installation
Step1: Selecting a Mounting Location
Select the mounting location for best coverage of the area 
that is to be protected (see Preliminary Considerations and 
Coverage Patterns). 
Step 2: Registering the Detector in the
System
The detector must identify itself to the system's receiver 
(control panel) during the registration process. 
1. 
Set the system to registration mode. 
2. 
Go to the main menu and select  
[9] Programming > [1] Devices > [1] Zones. 
3. 
Select a zone and press ʹʹ. The system enters into 
Learn mode. 
4. 
Unlock and remove the mounting bracket from 
the detector (see Figure 1 and Figure 3). 
Insert the supplied batteries into the battery 
holders paying attention to the correct polarity or 
remove the plastic protector strip if the batteries 
are already in place (see Figure 3). The detector 
sends a transmission to the system.  
If the transmission is successfully received by the 
system it plays a confirmation sound. 
If no confirmation sound is heard, send another 
transmission by pressing and releasing the tamper 
switch of the device (see Figure 3). 
Once the detector is successfully registered the 
system display shows: Save? 
5. 
Press  to confirm and continue entering other 
parameters for the chosen device (see Parameter 
Configuration). 
Step 4: Mounting the Detector
The detector must be tested on the exact mounting 
position before permanently mounting. 
1. 
Open the knockout holes of the mounting bracket, 
and use them as a template for mounting (see 
Figure 2). 
For Pet friendly model: In order to optimize pet 
immunity, always mount the detector vertically at a right 
angle to the floor. Make sure that an animal cannot get 
above the height of 1.5m (5ʹ) by climbing on furniture, 
shelving or stairs. 
2. 
Once the bracket is installed, slide and lock the 
detector onto the mounting bracket. 
3. 
Perform a Walk Test (see Performing a Walk Test). 
4. 
Insert and fasten screw into the hole located at the 
bottom of the detector to lock the detector to the 
mounting bracket (see Figure 4). 
Step 5: Performing a Walk Test
NOTE: The detector needs approximately 90 seconds to 
warm up after applying power. 
Go to the systems main menu and select [7] Service > [6] 
Walk Test and press ʹ. 
During Walk Test mode, walk through the entire field of 
view of the detector and confirm that the LED activates 
and deactivates accordingly (see LED Indication).  
 
Verify that the system receiver also receives the signals. 
NOTE: Wait for ten seconds, after each detection, before 
continuing the test. 
After completing the walk test, reset the system to 
Normal mode. 
LED Indication
The LED indicator is lit every time a transmission is 
made. To enable/disable LED indication, refer to 
Parameter Configuration section. 
Parameter Configuration
2‐Way parameters can be modified from the system. 
Go to the main menu and select [9] Programming > [1] 
Devices > [1] Zones > [11].Sensor Par. 
LED: 
Enable* / Disable 
PIR Sensitivity: 
Low* / High 
Alarm Delay: 
1‐20 minutes (3 mins.*) 
Camera Resolution:  
QVGA (320X240)*,  
VGA (640X480) 
Color: 
Color* / B&W 
Compression: 
Low* / High 
Flash: 
Enable / Disable* 
# of Pictures: 
1‐9 (3*) 
# of Different Pictures. 
1‐9 (0*) 
Picture Delay: 
0‐450 ms (480 ms*) 
User Monitor: 
Enable* / Disable 
Zone Assignment: 
Any of up‐to four zones 
can trigger a picture 
capture (00‐00‐00‐00*). 
Medical Trigger: 
Enable / Disable* 
Panic Trigger: 
Enable / Disable* 
Fire Trigger: 
Enable / Disable* 
* = default 
For additional information refer to the System Installer 
Manual. 
Camera Test and Snapshot Events
A camera test image can be taken using web/smartphone 
apps on systems supporting these applications. 
Snapshot events detected by the PIR camera are recorded 
into the camera's memory. The event record consists of 
the date and time stamp, a detailed description of the 
event including its source and an image record. 
Diagnostics
You can perform diagnostic tests on your detector using 
the system receiver. Diagnostics includes testing the 
detector battery status and communication between the 
detector and the system.  
For additional information refer to the System Installer 
Manual. 
Battery Replacement
1. 
Unlock and slide the detector from the mounting 
bracket. 
2. 
Replace the batteries paying attention to the 
correct polarity. 
3. 
Slide and lock the detector to the mounting 
bracket. 
CAUTION – Risk of explosion if battery is replaced by 
an incorrect type. Dispose of used batteries according to 
local regulations. 
 
Specifications
Electrical
Battery Type: 
2 x CR 123, 3V Lithium 
Battery Life: 
2 batteries – 3 year typical 
lifetime 
Current 
58 A standby; 
Consumption: 
200 mA max. peak at capture 
with flash 
Supervision 
10 minutes 
Transmission: 
RF transmitting 
868MHz, 433MHz ‐ models 
frequencies: 
EL5855 and EL5855PI 
Optical
Filtering: 
White Light Protection 
Pet friendly: 
Up to a 45 kg animal 
immunity (pet model) 
Physical
Size (L x W x D): 
120 x 65 x 35 mm (4.7 x 2.6 x 
1.8 in) 
Weight: 
100 grams (3.52 oz.) 
Environmental
RF Immunity: 
According to EN50130‐4 
Operating 
‐10C a 55C (14F a 140F) 
Temperature: 
Storage 
‐20C a 60C (‐4F a 140F) 
Temperature: 
Camera
Type: 
CMOS digital image sensor 
Lux: 
0 Lux (total darkness) 
View Angle: 
H 90 V 73 
Preliminary Considerations
 
Do not install outside 
Do not install near 
windows 
 
 
Do not install near 
Do not install near 
vents (air, heat, or AC) 
ceiling fans 
 
 
Do not install in 
Do not install in direct 
extreme temperatures 
sunlight 
 
Ok for sites with small pets 
 
 
 
PIR Coverage Patterns
PIR Model 
 
PET Model 
 
 
 
Camera Coverage
Side View 
Top View 
 
 
 

Advertisement

loading

Summary of Contents for EL EL4855

  • Page 1 Enable* / Disable  Once the detector is successfully registered the  Temperature:  Zone Assignment:  Any of up‐to four zones  system display shows: Save?    Storage  ‐20C a 60C (‐4F a 140F)  can trigger a picture  Temperature:  PET Model  5.  Press  to confirm and continue entering other  capture (00‐00‐00‐00*).  Camera parameters for the chosen device (see Parameter  Models: EL4855/EL4855P   Medical Trigger:  Enable / Disable*  Configuration).  Type:  CMOS digital image sensor  Panic Trigger:  Enable / Disable*  Lux:  0 Lux (total darkness)  Step 4: Mounting the Detector   Fire Trigger:  Enable / Disable*  View Angle:  H 90 V 73  Installation Instructions The detector must be tested on the exact mounting ...
  • Page 2 Ordering Information E8USX45PIR0A  EL5845 1&2Way  PIR,  E4USX45PIR0A  868MHz / 433MHz  E8USX45PET0A  EL5845PI 1&2Way  PET,  E4USX45PET0  868MHz / 433MHz    RTTE Compliance Statement: Hereby, Electronics Line 3000 Ltd. declares that this  product is in compliance with the essential requirements  and other relevant provisions of Directive 1999/5/EC. The  declaration of conformity may be consulted at  www.electronics‐line.com  Electronics Line 3000 Ltd. Limited Warranty EL and its subsidiaries and affiliates (ʺSellerʺ) warrants  its products to be free from defects in materials and  Figure 1  workmanship under normal use for 24 months from the  date of production. Because Seller does not install or  connect the product and because the product may be  Corner used in conjunction with products not manufactured by  Mount the Seller, Seller cannot guarantee the performance of the  security system which uses this product. Sellersʹ  obligation and liability under this warranty is expressly  limited to repairing and replacing, at Sellers option,  within a reasonable time after the date of delivery, any  product not meeting the specifications. Seller makes no  Wall Mount other warranty, expressed or implied, and makes no ...

This manual is also suitable for:

El4855p