8
Configure and Wire to Match
Serial Devices
Configure serial settings on the Basic Modem Settings tab to match your serial
device.
Configure the DIP Switch to match your serial device.
Figure 5. Serial Settings - DIP Switch Configuration
(Wiring examples are located in the manual. See Step 4 for terminal block layout.)
Terminal Block Signal Direction:
o RS-232 (modem is a DCE device):
TD – Input, RD – Output, RTS – Input, CTS – Output.
o RS-422/485 Four Wire:
TDA(-)/TDB(+) – Output, RDA(-)/RDB(+) - Input
o RS-485 2-Wire :
A(-) and B(+) Signals are tied together by
the DIP Switch and are bi-directional.
You are now ready for field installation.
9
UL Class 1 / Division 2
Operating Voltage – 10 to 30 VDC
WARNING- SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C
AND D HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF ANY COMPONENT
MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.
WARNING - EXPLOSION HAZARD – WHEN IN HAZARDOUS LOCATIONS,
TURN OFF POWER BEFORE REPLACING ANTENNA.
Intended Use of Equipment – please see the B+B SmartWorx Data Sheets and
Quick Start Guides for each Zlinx Xtreme product for explanations of the intended
use of this equipment.
Wiring Terminals – Use Copper Wire Only, one conductor per terminal.
Wire Range 30 – 12 AWG.
Maximum Surrounding Ambient Air Temperature: 74°C
UL Class I, Division 2 Wiring Methods. The Zlinx Xtreme enclosure is provided with
two conduit knockouts that serve as wiring provisions for Class I, Division 2 wiring
methods per the National Electrical Code (NEC).
Document Number: 710-11426-00_ZXTx-RM_2117qsg
The following instructions include procedures to be followed in order to ensure UL
"separation between circuits" as defined in the NEC:
The low-voltage (LV) wiring – DC power, analog & digital signals – must be separated
from the high voltage (HV) wiring for the relay contacts. In all cases HV wiring must be
rated minimum 250V.
Separation between circuits can be accomplished by using one of the three following
methods:
a. Use one conduit knockout to route LV wiring and the second conduit knockout to
route the HV wiring, OR see methods 2 and 3 below.
The remaining two methods use one conduit knockout for all wiring. In this case, a
UL Recognized (UL type QCRV2) conduit plug must be used per the NEC to plug
the second conduit knockout.
b. Enclose LV wiring in a 250V rated insulated sheath to separate it from the HV
wiring, OR
c. Use 250VAC rated wires for both LV and HV wiring.
Temperature rating of field installed conductors - Field conductors shall be rated
60°C/75°C minimum (either are acceptable) and sized accordingly.
When conduit openings are not being used, a UL Recognized plug (type QCRV2)
shall be used.
The following is UL-required information regarding the Sealed Relay Devices:
WARNING – Exposure to some chemicals may degrade the sealing properties of
materials used in the Sealed Relay Device.
RECOMMENDATION – It is recommended to inspect the sealed relay device
periodically and to check for any degradation of the materials and to replace the
component product, not the sealed device, if any degradation is found.
Sealed Relay Device Information:
Sealed Device: Relay Models G6RL-14-ASI-DC5, G6RL-14-ASI-DC6, G6RL-14-SR-
ASI-DC5 or G6RL-14-SR-ASI-DC6 manufactured by Omron Corp.
MANUFACTURER TYPE
Relay Case and Base
Mitsubishi Engineering
Plastics Corp.
Sealant
Three Bond Ltd.
Recommended Accessories
IP67 Power Supply, 24VDC, 60W
Panel Mount
# CLG-60-24
Conduit Mounting Kit
# ZXTMT
1-888-948-2248 | Europe: +353 91 792444
advantech-bb.com
707 Dayton Road | PO Box 1040 | Ottawa, IL 61350
Phone: 815-433-5100 | Fax: 815-433-5109
www.advantech-bb.com | E-mail: support@advantech-bb.com
QUICK START
GUIDE
5010GN6-30M8AM
TB2225G
Before you begin, be
sure you have the following:
+ Zlinx Radio Modem (ZXT24-RM or ZXT9-RM)
+ CD (w/Zlinx Manager Software, Manual)
+ Mounting Ears and Hardware
Required - sold separately:
+ 10-30 VDC Power Supply (not included)
+ USB Cable (not included)
+ Conduit Mounting Accessories (not included):
_Conduit Accessories
_Cable Gland
Fast and easy on the web:
ZXT24-RM
ZXT9-RM
Zlinx™ Xtreme Radio Modem
www.advantech-bb.com

Advertisement

loading

Summary of Contents for B+B SmartWorx ZXT24-RM

  • Page 1 + 10-30 VDC Power Supply (not included) TURN OFF POWER BEFORE REPLACING ANTENNA. + USB Cable (not included) Intended Use of Equipment – please see the B+B SmartWorx Data Sheets and Conduit Mounting Kit + Conduit Mounting Accessories (not included):...
  • Page 2 Install Zlinx™ Manager Software Insert the CD into your CD ROM Drive. The Zlinx™ Manager Install Wizard should start. Follow the on-screen instructions to install the software. If Auto Run is disabled, locate the ZlinxMgr.exe file on the CD-ROM drive and double click to launch it.

This manual is also suitable for:

Zxt9-rm