Download Print this page

Flash MONOTRON 300 C User Instruction

2 channels electronic time switch

Advertisement

Quick Links

Réf. 23842
Réf. 23852
2 channels electronic
time switch
weekly cycle
MONOTRON 300
MONOTRON 300 C
User instruction
Major characteristics
Product delivered with current time and date set.
Automatic change of winter / summer time
Programming key
(23852 version).
- for permanent waivers,
- for program copy or save.
Programming for day or group of days.
56 program steps On, Off.
Permanent overrides On or Off (
on).
Temporary overrides On or Off (
Display bar graph of daily profile for both channels.
Keyboard locking possible
.
Programmable with power off.
Réf.23852
Réf.23842
9419.063.02/01.03
Keys
menu
:
selection of operating mode
auto : mode of running according to the pro-
gram selected.
prog : new for programming mode.
C
prog : modif to modify an existing
program.
: checking of the program.
: modification of time, date and
selection of the winter / summer time
change mode
+and-
: navigation or setting of values.
C1
: in auto, mode, selection of
C2
.
enter
: to validate flashing information
on display.
: to return to the previous step.
You may return into auto mode at any moment
using menu.
permanent light
If no action is taken for 1 min, the switch returns
flashing).
into auto mode.
Reset
● Program reset:
the program may be completely cleared by
simultaneously pressing the 3 following keys:
menu, ok,
be kept.
● Total:
pressing simultaneously the -, +, ok, menu,
keys lets you clear the entire contents of the
product.
Following a total reset it is necessary to reset
the time and day of the device.
.
overrides, or waivers.
. The time and the date will
FLASH s.a.s. - 33, rue Saint Nicolas - BP 152 - 67704 Saverne Cedex France - http://www.flash.fr

Technical specifications

Electrical characteristics
● Supply voltage:
● Frequency
● Power consumption :
max. 0,5 VA à 50 Hz
● Output: 2 changeover volt free contacts
● Maximum load:
AC1
Cos φ = 0,6
Incandescent lighting
Halogen lighting 230 V
Compensated fluorescent tubes //
(max. 45 µF)
Non compensated fluorescent tubes,
compensated in series
Compact fluorescent lamps
● Minimum current.
AC1
● Galvanic insulation between power supply and
output = 4 kV
● Degree of pollution :
Functional characteristics
● Programming capacity: 56 pas
● Minimum time between 2 steps: 1 minute
● Running accuracy: ± 1,5 sec / 24h
● Operating reserve: lithium battery provides
5 years of backup.
● The product is set into standby state
(display switched-off) after 1 minute with
power off.
It switches back into auto mode as soon as
power is back or when pressing any key.
● Protection degree: IP 20
Environment
● Operating temperature:
● Storage temperature:
-20 °C to +70 °C
Connection
● Flexible capacity:
● Rigid capacity:

Connection diagram:

230 V AC ± 15%
50/60 Hz
µ16A 250 V~
µ10A 250 V~
2300 W
2300 W
400 W
1000 W
500 W
100 mA 250 V~
standard
-5 °C to +45 °C
1 to 6 mm
2
1,5 to 10 mm
2

Advertisement

loading

Summary of Contents for Flash MONOTRON 300 C

  • Page 1: Technical Specifications

    Connection diagram: product. Following a total reset it is necessary to reset the time and day of the device. Réf.23852 Réf.23842 9419.063.02/01.03 FLASH s.a.s. - 33, rue Saint Nicolas - BP 152 - 67704 Saverne Cedex France - http://www.flash.fr...
  • Page 2 Two types of operation: Days: 1 = Monday, 2 = Tuesday, 3 = pressure: temporary waiver. Off and Wednesday... 7 = Sunday. flash. The next program A. Permanent override: step will let you return to the auto- Insert the key into the switch.

This manual is also suitable for:

Monotron 300