Download Print this page

LDK Solar LDK-160D-24s Installation Manual

Photovoltaic modules

Advertisement

Quick Links

LDK SOLAR CO. LTD.
1、 、 、 、 INTRODUCTION
This guide contains information regarding the installation and safe handling of
module. All instructions should be read and understood before attempting to install. If there are any
questions, please contact LDK Solar Technical Service department for further explanation.
The following document refers to the following crystalline modules manufactured by LDK Solar:
Mono-crystalline:
• LDK-160D-24(s) to LDK-200D-24(s), LDK-200D-20(s) to LDK-250D-20(s).
• LDK-200D-20 to LDK-250D-20.
Poly-crystalline :
• LDK-160P-24(s) to LDK-200P-24(s), LDK-200P-20(s) to LDK-250P-20(s) and LDK-250P-24(s)
to LDK-290P-24(s).
• LDK-200P-20 to LDK-250P-20 and LDK-250P-24 to LDK-290P-24.
1.1 Disclaimer of liability
Because the use of this manual and the conditions or methods of installation, operation, use and
maintenance of photovoltaic (PV) product are beyond LDK Solar's control, LDK Solar does not accept
responsibility and expressly disclaims liability for loss, damage, or expense arising out of or in any way
connected with such installation, operation, use or maintenance.
No responsibility is assumed by LDK Solar for any infringement of patents or other rights of third
parties, which may result from use of the PV product. No license is granted by implication or otherwise
under any patent or patent rights.
The information in this manual is based on LDK Solar's knowledge and experience and is believed to
be reliable; but such information including product specification (without limitations) and suggestions
do not constitute a warranty, expresses or implied. LDK Solar reserves the right to change the manual,
the PV product, the specifications, or product information sheets without prior notice.
1.2 Product identification
Each module provides the following information:
Nameplate: describes the product type, rated power, rated current, rated voltage, open circuit voltage,
short circuit current, all as measured under standard test conditions, weight, dimension etc. the
maximum system voltage is shown on the nameplate.
Bar code: each individual module has a unique serial number. There is only one bar code on module. It
is permanently attached to the interior of the module visible when viewing from the front of the module.
This bar code is inserted at the beginning of laminating.
INSTALLATION GUIDE FOR
LDK SOLAR PHOTOVOLTAIC MODULES
Version: April 2011
LDK Solar
photovoltaic
Figure 1. Example of LDK module label
1.3 Quality and Safety Standards
LDK Solar photovoltaic modules meet all the requirements by the following
official Standards in terms of Quality and Safety:
IEC 61215: Design qualification and type approval
IEC 61730-1 and 2: Photovoltaic module safety qualification
UL1703-2002
ULC/ORD-C1703-01
ULand Canadian Standard for safety flat-plate Photovoltaic modules and
panels
ISO 9001:Quality management system for manufacture and sales of
Photovoltaic solar modules

Advertisement

loading

Summary of Contents for LDK Solar LDK-160D-24s

  • Page 1 No responsibility is assumed by LDK Solar for any infringement of patents or other rights of third parties, which may result from use of the PV product. No license is granted by implication or otherwise under any patent or patent rights.
  • Page 2: Installation

    61730 with Application Class A, and as Safety Class II according to the IEC 61140. Fire safety has LDK Solar PV modules should be installed in a location where they will receive the maximum amount been rated as Class C, reaching all requirements to be mounted on Class A roofs.
  • Page 3 3.2 Mechanical installation The clips must only fix the modules by the contact with the frame. Do not allow contact between clip and glass. Do not mount the modules by pressure clips out of the specified area. Module mechanical resistance Use always structures and materials specifically developed and certified for photovoltaic modules could be affected.
  • Page 4 Modules are fitted with pre-assembled cable leads and safe plug & socket connectors to use for the terminals or defective bypass diodes. Please, contact the LDK Solar Technical Service if the system electrical connections; these cable leads and connectors must not be removed or cut off problem could not be resolved.