Hanwei GE-201 Operating Manual

Ge series gas detector with battery backup design

Advertisement

Quick Links

河南汉威电子有限公司
GE Series Gas Detector with Battery Backup Design
Introduction
GE series Gas leak alarm is a kind of wall-hung household gas alarm designed to detect
the concentration of combustible and toxic gases or vapors. It provide a visual and audible
signals when the gas concentration reaches presetting level, remind you take prompt
favorable action, you may start up other link equipment, ventilate gas or shut off gas supply
to avoid Fire, explosion, suffocation, and other evil accident. The alarms are available for
liquefied petroleum gas (LPG), natural gas (Methane), propane, Hydrogen, town gas,
smoke, etc. They are not only installed at home, but also used at any other potentially
hazardous areas.
MCU control, Reliable without false alarming
Locale sound and light alarming,Drive Long-distance Alarming System
Ventilate good air circulation or shut off gas supply link equipment
 
Technical Conditions
Operating Voltage: AC220±10% / AC110v±10% or DC12V
Power Consumption:≤3W Size
Operating Time: -10℃~50℃
 
Model
GE - 201
GE - 221
GE - 401
GE - 601
GE - 501
GE - 701
GE- 801
GE - 901
Automatic Resume
Optional Function: Gas Shut Off VALVE□ Output pulse 10Hz DC8V/Max200mA, When alarming appears;
Relay Output □N.O Max AC220V 3A
Battery Backup□ 4 hours lasting without other power supply
 
Operating Manual
、 Fix gas alarm on the wall or Roof near the gas cooker or other sources within 2-4m interval. according to gas sources
1
Character, Choose alarm location as follows:
・LPG:Fix it within 0.3 meters above the ground (LPG is heavier than Air)
・Coal Gas, Natural Gas :Fix it within 0.3 meters below the Roof ( Combustible gas is lighter than Air)
・Avoid such installation:Windows with strong wind, Exit、water fog and drop place;easy polluted or high tem
environment near Oven, covering around。
2、Connect the Power supply, (If need ventilate fan, electrovalve other link equipment, please connect corresponding
circuit firstly.) Preheat the alarm 1 min, the alarm without detecting function.1 MIN later, the alarm enter into
detecting status.
3、If the flammable gas in the air reaches the preset alarming concentration, the alarm enter into alarming status, the
Alarm red LED light or flash, the buzzer give sound alarming, drive the relay or valve shut off gas supply, If the
alarm connect the ventilation fan or other relative electronics, it also open automatically, ; At the same time, please
cut off gas supply promptly, open the window, ask professional worker to remove the fault, The alarm with gas cut
off valve type shall output one close pulse signal.
 
In the interest of continued product improvement, we reserve the right to change design features without prior notice
TEL: 86-371-65333098 65333099 FAX: 86-371-65333090
Hum:<95%RH
Detecting Gas
Response time
LPG
Combustible gas
Natural Gas
Combustible gas
Coal Gas
CO
Hydrogen
CO+Combustible gas
 
Alarming Preset Level (Optional)
≤20S
10%LEL ±30%
≤20S
10%LEL ±10%
≤20S
5000ppm CH
≤20S
2000ppm LPG ±30%
≤20S
1000ppm Coal Gas ±30%
≤2.5min
150ppm CO ±30%
≤20S
1000ppm H
≤2.5min
150ppm CO/1000ppmLPG ±30%
HANWEI ELECTRONICS CO.,LTD 2002/2       
E-mail: sensor@371.net
http://www.hwsensor.com
±30%
4
±30%
2
Can be specified
  
 