Prior to Use
・ Please read this instruction manual carefully.
・ Please use product only as directed or severe damage to the product may occur.
・ Not properly following these guidelines may result in extremely hazardous conditions that could cause electrical shock or fire.
WARNING
・ Do not modify the product nor remove the protective enclosure. Under the protective enclosure are
contained high voltage and high temperature components during normal operation and after complete shutdown.
Avoid electric shock or burns by avoiding them.
・ Under the protective enclosure are contained high voltage and high temperature components during normal operation and
after complete shutdown. Avoid electric shock or burns by avoiding them.
・ Keep face and hands away at all times during operation to avoid unexpected injury.
・ DANGER. Risk of fire, electric shock, and injury. DO NOT continually operate if there is smoke, odor, or irregular noise. Instead
immediately turn off the power and contact us. Do not attempt to repair it yourself because it is dangerous to do so.
・ DANGER. Risk of fire, electric shock, and injury. DO NOT insert or drop any object in openings, this could cause unit failure or
severe hazardous conditions.
・ DANGER. Risk of fire, electric shock, and injury. DO NOT use the product with condensation present, this could result in electric
shock or fire.
CAUTION
・ This power supply is intended to be used as a component of a larger system of electrical equipment.
User is responsible for the safe design when this product is to be integrated in the equipment which requires
particularly high quality and reliability. There is a possibility to endanger persons or property by a failure or
malfunction of this product.
・ Avoid sharp and sudden impacts to this unit such as dropping or damage will likely result.
・ Ensure and maintain input voltage, output current, output power, ambient temperature, and humidity within specification or unit
may be damaged.
・ Safety standards for this product are based on the condition that the product is to be used with forced air cooling. To prevent
the temperature of internal parts from exceeding the specification, ensure that the product is exposed to proper airflow when
installing
・ Ensure that wires are properly secured to the input and output terminals as specified in this manual.
・ Be sure to turn off the power before making the output connection.
・ DO NOT use in a special environment (e.g. in the presence of strong electromagnetic field or erosive gas)
or environment where conductive foreign substance is present.
・ DO NOT use or store product where condensation may occur due to moisture or humidity. For use in such conditions,
waterproof protection is necessary and must be installed.
・ Do not operate under over current or short-circuit conditions for more than 10 seconds otherwise damage
and electrical insulation failure will likely result.
・ No stress (e.g. twist, deflection) should be applied to the print board when the product is installed.
・ Avoid impacts, such as dropping this product.
・ Do not apply the load to signal connector CN501.
・ DANGER. Output of this product is regarded as hazardous energy so this should not be accessible to end users.
・ Use appropriate connecters for the terminal connection.
For the crimping of the contact, use the crimping tool recommended by the manufacturer.
・ Prevent accidental contact with the output terminal of this product from dropped items such as tools by insuring proper
orientation and shielding/cover.
・ Turn off the input power and ensure that the input and output terminal voltage drops to zero.
・ This product uses fuses in the double pole/neutral line. When it is used for information processing equipment
(IEC/EN/UL60950-1), the following label must be provided for service engineers.
CAUTION DOUBLE POLE / NEUTRAL FUSING 】
Special Instructions for IEC/EN/UL60601-1
CAUTION
・ These products are not suitable for use in the presence of flammable anesthetic mixtures with oxygen or with nitrous oxide.
・ These products have not been assessed to IEC/EN/UL60601-1-2(EMC), but EMC test data is available from us.
PFS300A
Series
UL60950-1, #E237238
UL60601-1, #E320635
Instruction Manual
RoHS Compliant
10001-005WE-00

Advertisement

loading

Summary of Contents for Daitron PFS300A-12

  • Page 1 PFS300A Instruction Manual Series UL60950-1, #E237238 UL60601-1, #E320635 RoHS Compliant Prior to Use ・ Please read this instruction manual carefully. ・ Please use product only as directed or severe damage to the product may occur. ・ Not properly following these guidelines may result in extremely hazardous conditions that could cause electrical shock or fire. WARNING ・...
  • Page 2 . Terminal Explanation ・ Ensure AC power is off prior to connecting inputs and outputs. ・ Connect FG terminal to earth terminal of device or equipment. ・ Route AC and DC wires separately to minimize noise. ・ Be sure to use each terminal (pole) of the terminal block at 20A or less. ●...
  • Page 3 2.機能説明 Function explanation Input voltage Over-Voltage Protection(OVP) ・ AC input voltage range: 85-264VAC (47~63Hz) ・ During an over voltage fault OVP circuitry will disable output ・ To avoid damage, please use within recommended range until fault is removed and unit is allowed to reset. ・...
  • Page 4: Remote On/Off

    When the load line is long, the ripple on the load edge may become large unless a capacitor, such as an electrolytic capacitor or a film ・ This Daitron power supply unit is configurable in series capacitor is connected. The output ripple cannot be measured accurately if the ground lead of the oscilloscope is too long.
  • Page 5: Mounting Orientation

    .取付け方法 Mounting Method Mounting orientation ・To meet the requirement of 60950 PFS300A-12 ・ Four possible mounting configurations: Terminal Block Terminal Block Ambient Temperature(℃) PFS300A-15、24、30、48 Terminal Block Terminal Block Output derating Ambient Temperature (℃) ・ For the four possible mounting configurations and varying temperatures of operation, please refer to below curve: ・...
  • Page 6: Mounting Method

    Temperature limitation of each components surface If you need to calculate more in detail to choose suitable a far for your application, please refer to information below. ・ Please address specific temperature range of each component. ・ Please test under worst case conditions. ・...
  • Page 7: Troubleshooting

    4.Connections ・ Using twisted pairs for I/O and routing them separately from output load wire is ideal to minimize noise interference. ・ For improved noise filtering, add lower value of electrolytic capacitor (Section 2-11, 47µF) ・ Minimize length of output load wiring. ・...