Download Print this page

Neteon EH2305-1Fm Hardware Installation Manual

5/6/8-port industrial din-rail unmanaged ethernet switch

Advertisement

Quick Links

Industrial DIN-Rail Unmanaged Ethernet Switch
5/6/8-port Industrial Unmanaged Ethernet Switch
Hardware Installation Guide
Version 1.4
Updated on March, 2012
Introduction
Thank you for purchasing Atop EH-series Industrial Ethernet Switch.
This document intends to provide customers with brief descriptions about
the product and to assist our customers to get started using our devices.
Inside the Package
- Main Product
One EH2305-1Fm, EH2305-1Fs, EH2306 or EH2308 device
- Standard Accessories
Terminal block for power input
The hardcopy of EH-series Hardware Installation Guide
- Optional Accessories
US315-12(US), AC100V~240V 50/60HZ 12V/1.25A, US Plug (optional)
→ Atop PN:50500151120009G
US315-12(EU), AC100V~240V 50/60HZ 12V/1.25A, EU Plug (optional)
→ Atop PN:50500151120019G

Product Description

EH2305-1Fm
P1
P2
Fault
5-Port Unmanaged Fast Ethernet Switch
with Multi-mode Optical Fiber
F.G.
V-
4 ports of 10/100Base-TX with RJ-45 connector
P1
V+
1 port of 100Base-FX Multi-mode Optical Fiber
with ST connector
F.G.
V-
P2
V+
3
P1
P2
Fault
Data Link
F.G.
V-
P1
Rx
1
V+
5
Tx
F.G.
V-
P2
45.4mm
V+
3
4
EH2305-1Fs
5-Port Unmanaged Fast Ethernet Switch
1
2
with Single-mode Optical Fiber
4 ports of 10/100Base-TX with RJ-45 connector
1 port of 100Base-FX Single-mode Optical Fiber
with SC connector
45.4mm
EH2306
6-Port Unmanaged Fast Ethernet Switch
6 ports of 10/100Base-TX with RJ-45 connector
P2
P1
V+
V-
V+ V- F.G.
P2
P1
7
8
5
6
3
4
EH2308
1
2
Data Link
8-Port Unmanaged Fast Ethernet Switch
8 ports of 10/100Base-TX with RJ-45 connector
Rx
45.4mm
5
Tx

Hardware Installation

Step1: Installation on "DIN-Rail"
All EH23xx Switches are equipped with a DIN-Rail bracket attached
4
onto the rear panel. Please follow the below steps to fasten the
switch to the DIN-Rail correctly.
Tip the switch forward and press it against the DIN-Rail after align
the bracket springs to the DIN-Rail.
2
Press the bracket against the upper ledge of the DIN-Rail until it
clicks.
Notice :
The EH23xx series switch is designed to be mounted on a
well-grounded place, such as a metal panel.
Step2: Connecting the Power
P1
P2
Fault
Prepare the suitable power source and connect it into EH Switch
by Terminal Blocks (TB3/TB5).
F.G.
DC 9-30V for EH2305-1Fm, EH2305-1Fs and EH2306 switch
V-
P1
6
V+
products.
DC 9-48V for EH2308 switch product.
F.G.
You can connect two DC inputs for EH switch power if auto-backup
V-
P2
5
needed.
V+
Check P1/P2 power LED. The LED(s) will be lighted when the
device is ready.
3
4
3-pin Terminal Block for Power Input
1
2
Pin
V+
Signal
DC9-30V
45.4mm
5-pin Terminal Block for Power Input
Pin
V+
Signal
DC9-48V
Warning:
Before connecting EH23xx to the DC power input, please make sure
the DC voltage supplied by the power source is correct and stable.
Step3: Connecting the Network Devices
Connect your devices using standard UTP/STP cable with RJ-45
connectors to EH switch. (For the cable wiring diagrams, please
refer to section 7)
The corresponding RJ-45 or Fiber SC/ST LED will be lighted if the
Ethernet connection is linked successfully.
The LED will be blinked during data transfer by EH switch.
※UL Notice for Power supplier
All the series of EH products are intended to be supplied by a Listed
Power Unit marked with "LPS", "Limited Power Source" or "Class 2"
with output rate 9-30VDC 0.6A for EH2305-1Fm, EH2305-1Fs and
EH2306; 9-48V 0.35A(max) for EH2308.
Or, use the recommended power supplies in "Optional Accessories".
F.G.
V-
V+
V-
F.G.
0V
Frame Ground
P2
P1
V+
V- V+ V- F.G.
V-
F.G.
0V
Frame Ground

Advertisement

loading

Summary of Contents for Neteon EH2305-1Fm

  • Page 1: Product Description

    All the series of EH products are intended to be supplied by a Listed clicks. F.G. Power Unit marked with “LPS”, “Limited Power Source” or “Class 2” with output rate 9-30VDC 0.6A for EH2305-1Fm, EH2305-1Fs and 45.4mm EH2306; 9-48V 0.35A(max) for EH2308. Or, use the recommended power supplies in “Optional Accessories”.
  • Page 2: Led Indicators

    LED Indicators Warranty Policy 100Base-Fx Fiber SC/ST Port Connection SC Connectors ST Connectors There are four LED indicators located at the front panel of EH series. Warranty Conditions Name Status Description Fiber Port Both P1 and P2 on or off Fault Green Either P1 or P2 on...

This manual is also suitable for:

Eh2305-1fsEh2306Eh2308