Download Print this page

GE Interlogix ShatterPro Plus 5885 Installation Instructions

Motion sensitive acoustic sensor

Advertisement

Quick Links

ShatterPro
Motion Sensitive Acoustic Sensor
Model 5885
Installation Instructions
Wiring
Strip back the outer jacket on your wiring cable. This will
allow wires to flex in the case. Make sure the cable is slack in
the wall to avoid stressing the wires at their connections. The
unit should be connected to a UL listed power supply
capable of providing 4 hours of standby power.
Mounting
Ceiling Mount
1.
Mount unit in direct line of sight of windows to be
protected.
2.
Sensor can be mounted as close as 3.3 feet (1 m) from
glass and up to 12 feet (3.7 m) from glass.
3.
Select appropriate lens mask for field of view of PIR.
4.
Perform glassbreak and PIR walk test.
Note: When ceiling mounted, be sure to insert
"single spot" mask to reduce potential for false
alarms.
12'
Glassbreak
coverage
12'
PIR coverage
Ceiling Mount
ShatterPro Plus 5885
Plus
Microphone
Jumper J1 for
LED latch
Jumper J2 for
separate glassbreack
and PIR
Lens
Cover plate
Masking kit
-
Terminals for Power
9-16 VDC
Wall or Corner Mount
1.
Do not aim sensor directly at window - install so PIR
is covering the area of room you expect to have
occupied.
2.
Sensor can be mounted as close as 3.3 feet (1 m) from
glass and up to 12 feet (3.7 m) from glass.
3.
Select appropriate lens mask for field of view of PIR.
4.
Perform glassbreak and PIR walk test.
12'
PIR coverage
Wall Mount
Microphone
Jumper J1 for
LED latch
Jumper J2 for separate
glassbreak and PIR
PIR
GB
GB
PIR
+
NC
COM
NC
COM
Terminals for
Terminals for
PIR Relay
Glassbreak Relay
12' Glassbreak coverage
PIR coverage
Corner Mount
1

Advertisement

loading

Summary of Contents for GE Interlogix ShatterPro Plus 5885

  • Page 1 Note: When ceiling mounted, be sure to insert “single spot” mask to reduce potential for false alarms. 12’ Glassbreak coverage 12’ 12’ Glassbreak coverage 12’ PIR coverage PIR coverage PIR coverage Wall Mount Corner Mount Ceiling Mount ShatterPro Plus 5885...
  • Page 2 With Single Spot Mask Top View Top View 10° 10° 40’ 12.2m 40’ 12.2m Side View Side View 7’ 7’ 7° 2.1m 2.1m 10’ 20’ 30’ 40’ 10’ 20’ 30’ 40’ 3.0m 6.1m 9.1m 12.2m 3.0m 6.1m 9.1m 12.2m ShatterPro Plus 5885...
  • Page 3 Testing the Sensor The ShatterPro Plus provides two separate relays, one for GE Interlogix recommends testing the sensor to confirm that the glassbreak sensor and one for the PIR. This configura- the field of view is set correctly and that the glassbreak tion allows the ShatterPro Plus to be used in a variety of detector will detect at the desired mounting location.
  • Page 4 Listing ShatterPro Plus 5885-W White UL 639 Hand Held Tester 5709C GE Interlogix www.GE-Interlogix.com 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 Technical Service: 800-648-7424 FaxBack: 800-483-2495 12287 Rev F 09/03 © 2003 GE Interlogix...

This manual is also suitable for: