Download Print this page

Firestone 2097 Manual

Level command kit

Advertisement

Quick Links

PERFORMANCE SUSPENSION PARTS
I
NSTALLATION INSTRUCTIONS
Congratulations on your purchase of a new Level Command
kit. This kit was designed to provide inflation control of your
air helper springs. This kit will be an asset to your vehicle,
meeting nearly all of your air supply needs.
Please take a few minutes to read through the instructions,
identify the components, and learn how to properly install your
Level Command kit.
N
:
OTE
The Level Command kit can be used with all air helper
spring products. If you are installing an air suspension system,
do not install the air line tubing to the air springs as stated in
the suspension system instruction manual. If you are adding
the Level Command kit to an existing air suspension system,
you will need to deflate the air springs and remove the air line
tubing.
P
ARTS LIST
SINGLE AIR CONTROL PANEL
COMPRESSOR
RELAY HARNESS
30 FT. AIR LINE TUBING
STRAIGHT FITTING
T-FITTING
30
200
psi
0
L
C
EVEL
1
9285
1
9307
1
1
3055
1
3025
2
60
90
600
400
120
800
1000
kPa
PSI
150
OMMAND
N
C
OTE ON
ONNECTING THE AIR LINE TUBING
Cut the air line tubing as squarely as possible. To connect
the air line tubing to the fittings, push the tubing into the fittings
as far as possible. If for any reason the tubing must be removed,
first release the air pressure from the air helper spring. Push the
collar toward the body of the fitting and the pull out the tubing.
To reassemble, make sure the tubing is cut squarely and push
the tubing back into the fitting.
T
:
OOLS REQUIRED
• 3/16"
DRILL BIT
• 1/4"
DRILL BIT
• W
/
IRE CRIMPER
STRIPPER
• P
HILLIPS SCREW DRIVER
• (2) 7/16"
WRENCHES
10 -32 x 1" MACHINE SCREW
10 -32 LOCK NUT
#10 FLAT WASHER
RING TERMINAL
WIRE CONNECTOR
NYLON TIE
2097 / 2227
:
• 3/8"
DRILL BIT
• P
OWER DRILL
• P
LIERS
• U
TILITY KNIFE
• C
ENTER PUNCH
7
7
14
1
2
15

Advertisement

loading

Summary of Contents for Firestone 2097

  • Page 1 2097 / 2227 PERFORMANCE SUSPENSION PARTS 1000 EVEL OMMAND NSTALLATION INSTRUCTIONS OTE ON ONNECTING THE AIR LINE TUBING Congratulations on your purchase of a new Level Command Cut the air line tubing as squarely as possible. To connect kit. This kit was designed to provide inflation control of your the air line tubing to the fittings, push the tubing into the fittings as far as possible.
  • Page 2 CHECK VALVE BACK OF CONTROL PANEL FROM COMPRESSOR AIR SPRINGS...
  • Page 3 1 - S ELECT A MOUNTING LOCATION FOR THE CONTROL PANEL Select a mounting surface under the dashboard or other protected location. Using the control panel as a template, mark each of the mounting points with a center punch. Drill a 3/16" diameter hole on each center mark see Figure "B".
  • Page 4 7 - R OUTE THE ELECTRICAL WIRE Install the relay within three feet of the compressor. Nylon ties can be used to secure any excess wire and the relay neatly into place. Route the white wire labeled “Switch Panel” to the control panel.

This manual is also suitable for:

2227