1. Technical data

Type
TERRACE HEATER 10
TERRACE HEATER 15
2. Use
ECOSUN Terrace Heaters are designed for the zonal heating of winter gardens, enclosed and roofed balconies and terraces, garden
tents, churches, etc. – i.e., applications where they are protected against direct contact with the effects of the weather.
ECOSUN TH panels have a significantly lower surface temperature than halogen heaters, and they do not radiate unwanted light
when in operation.
It is possible to use panels at temperatures as low as +5 to +10°C; at lower temperatures the lamellas will become very cold and
the heat they radiate will be almost unnoticeable.
3. Installation
Tiltable brackets are used for the attachment of panels to the ceiling or wall. The brackets are supplied with the panel, disassem-
bled. Panels can also be hung from the ceiling using chains or cords.
Metal wall anchors must be used for the attachment of the brackets, chains or cords.
The radiant panel can be installed at an angle as well as vertically, but it mustn´t
be installed at an angle or vertically in such a way that the supply lead and termi-
nal are at the highest point of the panel. There is higher convection of heat when
the panel is tilted and this heat would irreversibly damage the electrical equip-
ment of the terminal.
TERRACE HEATER
Wattage
Voltage
[W]
[V]
1000
230 V 1N
1500
Protection
IP
class
1080x140x45
I
IP 45
1580x140x45
Dimensions
Weight
[mm]
[kg]
5
7,2

Advertisement

loading

Summary of Contents for Flexel TERRACE HEATER 10

  • Page 1: Technical Data

    Wattage Voltage Protection Dimensions Weight Type class [mm] [kg] TERRACE HEATER 10 1000 1080x140x45 230 V 1N IP 45 TERRACE HEATER 15 1500 1580x140x45 2. Use ECOSUN Terrace Heaters are designed for the zonal heating of winter gardens, enclosed and roofed balconies and terraces, garden tents, churches, etc.
  • Page 2 Horizontal installation: Vertical installation...
  • Page 3 Clearance distances. *there is a danger that the ceiling may be soiled by burnt particles in dusty and smoky environments Clearance distances from flammable objects: − min. 100 cm from the radiant surface • the panel mustn´t be placed directly under an electric socket 4.
  • Page 4: Important Information

    6. Important information During the first heating of the panel, burning out of the material takes place, which can cause a harmless smell (smoke) for a period of max. 60 minutes. Do not touch the heating segments in order not to make the radiant surfaces dirty (if necessary then only in clean textile gloves). The temperature of the surroundings of the heating panel (the temperature of the surrounding air) mustn´t exceed 30°C.

This manual is also suitable for:

Terrace heater 15