Download Print this page

3P Technik TCS5JBLA Installation And Operation Manual

Low-voltage top-up switch

Advertisement

Quick Links

3P Technik
TCS5JBL & TCS5JBLA
Low-Voltage Top-Up
Switch
Installation and Operation Manual
3P TCS5JBL/TCS5JBLA
Page 1
11/09/16

Advertisement

loading

Summary of Contents for 3P Technik TCS5JBLA

  • Page 1 3P Technik TCS5JBL & TCS5JBLA Low-Voltage Top-Up Switch Installation and Operation Manual 3P TCS5JBL/TCS5JBLA Page 1 11/09/16...
  • Page 2: Table Of Contents

    Table of Contents Description Of Operation......................2 Installation...........................2 Safety Precautions...........................2 Included Components........................3 Layout...............................3 Control Panel Mounting........................3 Connections.............................4 Float Switch..........................4 Solenoid............................4 Mains Supply 230Vac........................4 Operation............................4 Safety Precautions...........................4 Adjustments.............................5 Specifications..........................5 3P TCS5JBL/TCS5JBLA Page 2 11/09/16...
  • Page 3: Description Of Operation

    45deg, thereby ensuring a measured quantity of water is introduced to the tank and avoiding unnecessarily frequent top-ups. The float switch and solenoid circuits are both powered by a safe low-voltage, either 24Vdc (TCS5JBL) or 24Vac (TCS5JBLA) with limited current and over-voltage protection. Installation Safety Precautions Mains Voltage –...
  • Page 4: Control Panel Mounting

    The polarity of the solenoid connection is unimportant if you have the AC version of this unit (TCS5JBLA). If using the DC version, the pole marked L in the plug will be positive, and the pole marked N will be negative, although it is good practice to verify this with a multimeter during...
  • Page 5: Mains Supply 230Vac

    The level around which the system starts and stops the top-up cycle can be adjusted by moving the point at which the float cable is attached within the tank. The top-up duration can be adjusted by increasing or decreasing by the length of free cable to the 3P TCS5JBL/TCS5JBLA Page 5 11/09/16...
  • Page 6: Specifications

    Specifications Dimensions (W x H x D) 130mm x 94mm x 57mm Enclosure Material Polystyrene Ingress Protection IP66 UV Resistant Output TCS5JBL 24Vdc 0.63A max TCS5JBLA 24Vac 1.25A max 3P TCS5JBL/TCS5JBLA Page 6 11/09/16...

This manual is also suitable for:

Tcs5jbl