SMF PUMP OWNER'S MANUAL

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS • SAVE THESE INSTRUCTIONS
WARNING: Before installing this product, read and follow all warning notices and instructions accompanying this
pump. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage.
ATTENTION INSTALLER: This manual contains important information about the installation, operation, and safe
use of this product. This information should be given to the owner/operator of this equipment.
NOTE: When pump is mounted permanently within 5 ft. of the inside walls of a swimming pool, you must use
No. 8 AWG or larger conductor to connect to bonding conductor lug.
WARNING: To reduce the risk of injury, do not permit children to use this product unless they are closely
supervised at all times.
CAUTION: For hot tubs and spas, do not install within an outer enclosure or beneath the skirt of a hot tub or spa
unless so marked.
Designed,
Engineered &
Manufactured
in the USA.
2200 East Sturgis Road, Oxnard, CA 93030 • Phone 805.981.0262 • Fax 805.981.9403
www.waterwayplastics.com • waterway@waterwayplastics.com
810-0226.0315
©2015 Waterway Plastics

Advertisement

loading

Summary of Contents for Waterway SMF-115

  • Page 1: Important Safety Instructions

    CAUTION: For hot tubs and spas, do not install within an outer enclosure or beneath the skirt of a hot tub or spa unless so marked. Designed, Engineered & Manufactured in the USA. 2200 East Sturgis Road, Oxnard, CA 93030 • Phone 805.981.0262 • Fax 805.981.9403 www.waterwayplastics.com • waterway@waterwayplastics.com 810-0226.0315 ©2015 Waterway Plastics...
  • Page 2 WIRING WARNING: RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or damage to property.
  • Page 3: Pump Strainer Basket

    PUMP STRAINER BASKET This unit, sometimes referred to as the “Hair and Lint Pot”, is the unit in front of the volute. The lint pot must be installed using only teflon tape on the threads. Do not use liquid chemical thread sealant. The basket inside the chamber must be kept clean of leaves and debris at all times. View basket through the “See Through Lid”...
  • Page 4 WINTERIZING CARE OF ELECTRIC MOTOR PROTECT FROM HEAT If the air temperature drops below 35º F. the water in the pump can freeze and cause damage. Freeze damage is not warrantable. 1. Shade the motor from the sun. 2. Any enclosure must be well ventilated to prevent overheating. 3.
  • Page 5: Pump Disassembly

    PUMP DISASSEMBLY CAUTION: Be sure not to scratch or mar the polished seal faces. Seal will leak if faces are damaged. All moving parts are located in rear sub-assembly of this pump. 5. Remove the diffuser. Tools required: 6. Hold the impeller securely in place and remove the impeller lock •...
  • Page 6 SMF PUMP REPLACEMENT PARTS FIGURE 3 Part No. Qty Description Part No. Qty Description 3310330 Motor, 48-FRAME SQ FLG 3/4HP 115/230V 60HZ 319-1420 Diffuser Plate 819-0035 715-1200 3/8” Quarter Slot Plug (Sd Wet End) Bolt .375-16 X .875 Long 672-1350 Neoprene Motor Support Strip 805-0014 O-Ring, -014...
  • Page 7: Troubleshooting

    1. Air pockets or leaks in suction line. Remedy: a. Clean suction trap. a. See item 1a of this section above. Designed, Engineered & Manufactured in the USA. 2200 East Sturgis Road, Oxnard, CA 93030 • Phone 805.981.0262 • Fax 805.981.9403 www.waterwayplastics.com • waterway@waterwayplastics.com 810-0226.0315 ©2015 Waterway Plastics...