  • Page 1 Operation & Maintenance Manual Mojave CR170...
  • Page 2 OPERATING INSTRUCTIONS GENERAL SAFETY – ALL MODELS Please ensure you have read and understood these instructions fully, before attempting to operate this equipment. Failure to follow instruc- tions could damage the compressor and will invalidate the warranty. Never place anything on top of the unit and never obstruct its air vents. Leave a 300 mm gap all round the unit to let the air circulate.
  • Page 3 These units may hold water in the drip tray; therefore, it is important to ensure that they are isolated from the electrical supply before moving and sufficient time is allowed for ALL moisture to drain from the coil. Never remove any panels/covers whilst the unit is connected to the electrical supply.
  • Page 4 SET UP & OPERATION – ALL MODELS Never operate the units in very cold conditions – they work properly at temperatures ABOVE 5ºC. If the temperature in the room is above 35ºC, then switch the unit off as the compressor could overheat, resulting in possible failure which would invalidate the warranty.
  • Page 5 EQUIPMENT CARE – ALL MODELS Never use a dehumidifier except for its intended purpose. Keep the equipment clean & especially the coil faces. Blow out the coils with compressed air. Regularly check the water receptacle (every 3-4 hours) to ensure it does not overflow.
  • Page 6 MAINTENANCE – ALL MODELS ALWAYS DISCONNECT THE UNIT FROM ANY POWER SUPPLY BEFORE ATTEMPTING MAINTENANCE. The front face of the cooling coil requires cleaning periodically whenever the accumulation of dust etc becomes noticeable. The frequency of this is dependant on the conditions the unit is exposed to, but should be done at least once a month minimum.
  • Page 7 OPTIONS There are some options available when these models are purchased. These are described below. Electronic Hour Counter (Standard on the CR170) This indicates the number of hours the unit has run throughout its life. The counter is not resettable, so readings should be noted at the start and end of the drying cycle to determine the run time.
  • Page 8 Dual voltage function (Standard on the CR170) These models have a manually operated dual voltage selector switch. It can be plugged (once the appropriate plug has been fitted) into a standard 16 Amp 110v, or 13 amp 3 pin (13 amp fuse fitted) 230v 50 Hz power supply.
  • Page 9: Troubleshooting Guide

    TROUBLESHOOTING GUIDE ALWAYS CONSULT THIS GUIDE BEFORE RINGING YOUR SUPPLIER; THE MAJORITY OF REPORTED PROBLEMS ARE SIMPLY SOLVED IN THIS MANNER Problem Possible Cause Solution Unit Fails To Operate Power Failure Check Unit is Plugged Into Correct Power Supply & Unit Switched On Check Plug Fuse for Failure &...